Plans (711) S(0NZ0 &6o C)S 7 7 r4 II 1 J anuary 29,1999 l \II • � 11 _, Mr. Robert Poskins .I „ City of Tigard Building Department L�L�L� 13125 SW Hall Blvd. 41 4I L L S T42 0 1il Tigard, Or 97223 ARCHITECTS, P.S.C. PC 11 -44C Re: BUP# 98 -0520 ARCHITECTURE Eagle Hardware and Garden 12615 SW 72 Dear Bob, PLANNING This submittal package is in response to your letter dated December 11,1998. As I understand, per our past conversations, the Electrical and Plumbing drawings are being out sourced by the City and that the Oregon licensed contractor of the respected trade will be issued the permit. Fire Suppression drawings indicating the installation of the E.S.F.R. system INTERIORS will follow. BUILDING PLAN REVIEW RESPONSES t FIRE AND LIFE SAFETY / A\ t) Completed, please refer to A2.01 (Floor Plan) and A3.01 (Door or-Schedule). 2) Exit door #73 has been relocated to within the Greenhouse to oi'oeliminate the second intervening room. Please refer to sheet A2.01 or /1) %` sheet A8.01. 3) The suspended ceiling had been omitted. Metal ceiling joist with A5/8” type `X' gypsum to be implemented. Please see #41A7.02. 4A) Please see attached exhibit `A', Sheet A2.03. 4B,C) Please refer to A0.02 General Notes # 26, 27, and 28. 5) Please refer to A2.03. The A (triangle) indicates the location of each fire extinguisher at 75' maximum spacing. 919 1 2 4TH AVE N. E. 6A -E) Please see TVA's responses and drawings. SUITE 101 BELLEVUE, WA 98005 425.455.3203 425.455.9351 (FAX) www.sconzohallstrom.com n 7) Please see TVA's responses and drawings. HAZARDOUS MATERIAL QUANTITIES 1A -D) Please see TVA's responses. DEFERRED SUBMITTALS Items to be deferred shall be provided in the Design Build format. All drawings and calculations that are designed by others shall be wet stamped and signed by a registered professional. Submittal(s) will be provided to the Architect of Record for review. Then three (3) copies will be forwarded to the City of Tigard for final approval prior to fabrication of such submittal(s). STRUCTURAL 1) Please see Shutler Consulting Engineers' responses. Also, please be aware of the canopy framing change from pre- manufactured wood trusses to metal stud framing. 2) Please see Shutler Consulting Engineers' responses. 3) Please see Shutler Consulting Engineers' responses. 4) Please see submitted document, three (3) copies. ACCESSIBILITY 1) Please see A0.02 exit calculations table. As noted, there are 1644 O sq. in. of exit width provided verses 874 sq. in. of exit width required. Each 16' -0" BI- parting door is counted as 180 sq. in. of exit width due to its egress breakaway operation. Beseam Door information attached. Please see attached Exhibit `B'. 2) Please see enlarged floor plans on A2.07 and A2.09 and stair D sections on A7.02. C (/3) Please see #1/A2.07 Enlarged Mezzanine Plan, noted in lunchroom 6 along grid line `F.5' near line `9.4'. r (L4) Please see #1/A2.07 Enlarged Mezzanine Plan, noted in lunchroom along grid line `G' near line `9.4'. Also refer to interior elevation V /A3.03. Please contact me at (425) 455 -3203 if you have any questions. Ji Bryan P.M.