II 1 J anuary 29,1999
l \II • � 11 _, Mr. Robert Poskins
.I „ City of Tigard
Building Department
L�L�L� 13125 SW Hall Blvd.
41 4I L L S T42 0 1il Tigard, Or 97223
ARCHITECTS, P.S.C.
PC 11 -44C
Re: BUP# 98 -0520
ARCHITECTURE Eagle Hardware and Garden
12615 SW 72
Dear Bob,
PLANNING This submittal package is in response to your letter dated December
11,1998. As I understand, per our past conversations, the Electrical and
Plumbing drawings are being out sourced by the City and that the Oregon
licensed contractor of the respected trade will be issued the permit. Fire
Suppression drawings indicating the installation of the E.S.F.R. system
INTERIORS will follow.
BUILDING PLAN REVIEW
RESPONSES
t FIRE AND LIFE SAFETY
/ A\ t) Completed, please refer to A2.01 (Floor Plan) and A3.01 (Door
or-Schedule).
2) Exit door #73 has been relocated to within the Greenhouse to
oi'oeliminate the second intervening room. Please refer to sheet A2.01 or
/1) %` sheet A8.01.
3) The suspended ceiling had been omitted. Metal ceiling joist with
A5/8” type `X' gypsum to be implemented. Please see #41A7.02.
4A) Please see attached exhibit `A', Sheet A2.03.
4B,C) Please refer to A0.02 General Notes # 26, 27, and 28.
5) Please refer to A2.03. The A (triangle) indicates the location of
each fire extinguisher at 75' maximum spacing.
919 1 2 4TH AVE N. E. 6A -E) Please see TVA's responses and drawings.
SUITE 101
BELLEVUE, WA 98005
425.455.3203
425.455.9351 (FAX)
www.sconzohallstrom.com
n 7) Please see TVA's responses and drawings.
HAZARDOUS MATERIAL QUANTITIES
1A -D) Please see TVA's responses.
DEFERRED SUBMITTALS
Items to be deferred shall be provided in the Design Build format. All
drawings and calculations that are designed by others shall be wet stamped
and signed by a registered professional. Submittal(s) will be provided to
the Architect of Record for review. Then three (3) copies will be
forwarded to the City of Tigard for final approval prior to fabrication of
such submittal(s).
STRUCTURAL
1) Please see Shutler Consulting Engineers' responses. Also, please
be aware of the canopy framing change from pre- manufactured wood
trusses to metal stud framing.
2) Please see Shutler Consulting Engineers' responses.
3) Please see Shutler Consulting Engineers' responses.
4) Please see submitted document, three (3) copies.
ACCESSIBILITY
1) Please see A0.02 exit calculations table. As noted, there are 1644
O sq. in. of exit width provided verses 874 sq. in. of exit width required.
Each 16' -0" BI- parting door is counted as 180 sq. in. of exit width due to
its egress breakaway operation. Beseam Door information attached.
Please see attached Exhibit `B'.
2) Please see enlarged floor plans on A2.07 and A2.09 and stair
D sections on A7.02.
C (/3) Please see #1/A2.07 Enlarged Mezzanine Plan, noted in lunchroom
6 along grid line `F.5' near line `9.4'.
r (L4) Please see #1/A2.07 Enlarged Mezzanine Plan, noted in lunchroom
along grid line `G' near line `9.4'. Also refer to interior elevation V /A3.03.
Please contact me at (425) 455 -3203 if you have any questions.