Correspondence (681) . 6 l 9t , 603 - 2 , 0
rji
•
June 6, 2000
CITY OF TIGARD
Carlson Testing OREGON,
PO Box 23814
Tigard, Oregon 97223
(A
PERMIT NO: BUP 1998 -00520
OWNER: Eagle Hardware
PROJECT ADDRESS: 12615 SW 72nd
PROJECT DESCRIPTION: Retail complex
TYPES OF SPECIAL INSPECTION: As setout on the enclosed form
The owner has notified us that he /she will retain your services to perform Special
Inspections in accordance with the provisions of the State Building Code, permit
documents and special inspection requirements.
The owner or the owner's agent must also confirm with you that they have
authorized you to do the special inspection work.
As the regulatory agency, the City requires that you do the following:
1. Submit copies of all inspection reports promptly to the building division,
Architect, engineer, and the contractor.
2. Maintain one copy of each field report at the job site.
3. Submit a final report at the completion of each category of work that you
Inspect. (See UBC Appendix Chapter 13 for soils special inspection final
report requirements.)
If you fail to comply with the above requirements, there may be cause for the City to
revoke your authority as special inspector for this job.
Should you have any questions, please call me at (503) 639 -4171 X 392.
Sincerely,
Robert D. Poskin, C.B.O.
Senior Plans Examiner
13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772
CITY OF TIGARD
A Program for Inspection Services and/or Material Testing
City of Tigard: Plan Ck. No. 5 -40C
Project Title: Lowe's H.I.W.
Address: 12615 SW 72nd
Architect of Record: Sconzo/Hallstrom Phone: 425 -455 -3203
Address: 919 — 124 Avenue, NE — Bellevue, WA. 98005
Structural Engineer of Record: JR Bonnett Engineering Phone: 509 -534 -3929
Address: 803 East 3r Avenue, Spokane, WA. 99202
Geo- Technical Engineer of Record: Phone:
Address:
Provide the following information for the testing agency chosen to provide inspection services and/or
testing.
* Testing Agency: Carlson Testing Phone: 684 -3460
Address: PO Box 23814, Tigard OR. 97281
Geo- Technical Agency: Phone:
Address:
The owner certifies that the above noted Agency has been employed to conduct the special
inspections or observations required herein.
* "Notice" Special Inspection reports shall not preclude the need to have City of Tigard inspection
approval on all re -bar placement.
Signature of Owner Phone No. Date
Df1/ZE �;,," &T4...1 ` 140fAcrizekn & !Ll
Print name Company name
The following is a list of special inspection and/or services required by the 1998 Oregon Structural
Specialty Code and Tigard Municipal Code 14.06.010 through 14.06.040.
The special inspections and/or testing services required for this project to be provided by the Testing
Agency, Structural Engineer or Geo - Technical Engineer of Record are as follows:
1. Structural Masonry
Special Note to Carlson testing — This voids the Special Inspection for Tilt -up
Inspections as approved on 2/11/99
*Special Inspectors for the Testing Agency shall be qualified, to the satisfaction of the Building Official,
for inspections of the particular type of construction or operation.
•Special inspectors shall observe the work assigned herein for conformance with the approved plans and
specifications and, submit copies of all inspection reports and, a final signed report in accordance with
OSSC, Section 1701.3 to the building official.
June 6, 2000
Sconzo/Hallstrom Architects CITY OF TIG�
919 — 124` Avenue, NE # 101 OREGON
Bellevue, WA. 98005
Attn: Jim Bryan
RE: Lowe's HIW BUP# 98 -00520
12615 SW 72 Avenue
Dear Jim:
Find enclosed copies of revised Special Inspection forms. Please provide the information hi-
lighted in yellow, and return the forms to me.
Secondly, we will not issue a new permit rather; we will amend the original permit to indicate
the structural and minor architectural changes as shown on the revised plans. Please advise your
Construction team that the amended drawings will take precedent over the original approved
drawings with the exception of the Civil. All inspections will be approved based on the drawings
dated 5 /15/00 stamped and approved as amended.
The fees required for the amended review and issuance are as follows:
(a) Building Permit $5,211.65
(b) Plan Revue $3,387.57
(c) Fire Life Safety Review $2,084.66
(d) State Surcharge $ 416.93
(e) CDC Bldg. Review $ 125.00
(f) CDC Plan Revue $ 125.00
Total $11,35.81
Payment received $ 5,448.45
Balance Due $ 590 .3
If you have questions regarding the contents herein, please call me at (503) 639 -4171 X392.
Sincerely,
T a.oicw
R kin CBO
Senior Plans Examiner
13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772