Report Main Office Salem Office Bend Office P.O. Box 23814 4060 Hudson Ave., NE P.O. Box 7918 Tigard, Oregon 97281 Salem, OR 97301 Bend, OR 97708 Carlson Testing Inc • Phone (503) 684 -3460 Phone (503) 589 -1252 Phone (541) 330 -9155 FAX (503) 684 -0954 FAX (503) 589 -1309 FAX (541) 330 -9163 Special Inspection FINAL SUMMARY LETTER -c c -( March 8, 2001 T0003925.A City of Tigard C O P FI Tigard, OR 97223 -8199 Attn: Budding Department Re: Lowes H.I.W. — Retaining Wall 12165 SW 72 Avenue Tigard, OR Permit No.: SIT9800048 Dear Sir or Madam: This is to certify that in accordance with Section 1701 of the Uniform Building Code and Chapter 24.20, Title 24, we have performed special inspection of the following item(s) per our inspection reports only: Reinforcing Steel Concrete — Compressive Strength Testing Installation of Epoxy Anchors (as per attached letter from John Harper of Continental Dirt Contractors, Inc. 3/8/01) All inspections and tests were performed and reported according to the requirements of Project Documents and, to the best of our knowledge, the work was in conformance with the approved plans and specifications, approved change orders and applicable workmanship provisions of the State Building Code and Standards, as well as the structural engineer's design changes, approvals and verbal instructions. Our reports pertain to the material tested /inspected only. Information contained herein is not to be reproduced, except in full, without prior authorization from this office. If there are any further questions regarding this matter, please do not hesitate to contact this office. Respectfully submitted, CARLSON TESTING, IN . Douglas . Leach Chief Executive Officer mbw Attachment cc: Continental Dirt Contractors Whitaker -Ellis Builders JUB Engineers — Darral Moore Sconzo Hallstrom Architects — Jim Bryan Lowes H.I.W. — Bill Crocker P. \WORD REPORTSFINLTR \T0003925A 03/08/01 THU .14:39 FAX 2539399204 CONT DIRT rip 001 • . 1340 'M' Street S.E., Suite A ont Auburn, Washington 98002 (253) 939-5744 • (253) 927 -2544 � (253) 939 -5765 FAX r ntractors . Inc. CONTI1'225BU. EXCA VATING COtVTRA Doug Leech March 8 2001 • Carlson Testing Inc. Fax (503) 684 -0954 8430 S.W. Hun.ziker ph (503) 684 -3460 • P.O. Box 2381.4 , • • Tigard OR 97281 RE: Tigard Lowe's Hardware /Expired ICBO report for epoxy used. on kiosk retaining wall. • Dear Mr. Doug Leech: • Your inspection report indicates that an outdated tube ofepoxy was used to anchor kiosk retaining wall footings to adjacent canopy pier pad footings. The epoxy was purchased new at the time of the job but had an outdated ICBO report. The epoxy had not expired -only the ICBO report. There was no apparent problem with the epoxy. Continental Dirt Contractors hereby assumes liability for repair of structural deficiencies dire esulting from the use of the epoxy with the expired reports. . incerely: • 1/4 ^ John Harper, Project Manager • • • • • • • • • • • • • • • • •