Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans
f ■ I • I Performance i "� �� 'v � S � 2c � Data 1 Table 16-1 - Propeller Fan Gas Unit Heater Performance Data Cfm @ Outlet Motor Data Input MBh Output Thermal Std Air Temp Velocity Nom Speed Motor Fla Models Max Min MBh Efficiency (70 F) Rise F Fpm Hp Avg Rpm Type Motor/Unit GPND /GPPD -003 30.0 30.0 24.3 81% 700 30 700 'ho 1050 SP 1.3/2.1 GPND /GPPD -004 45.0 45.0 36.5 81% 800 42 750 'ho 1050 SP 1.3/2.1 GPND /GPPD -006 60.0 60.0 48.6 81% 1050 42 640 'ho 1050 SP 1.3/2.1 ' GPND /GPPD -007 75.0 75.0 60.8 81% 1100 50 672 'ho 1050 SP 1.3/2.1 GPND /GPPD -010 100.0 50.0 80.0 80% 1480 50 950 'ho 1050 SP 2.6/3.4 GPND /GPPD -012 125.0 62.5 100.0 80% 1650 56 900 1 ho 1050 SP 2.8/3.4 GPND /GPPD -015 150.0 75.0 120.0 80% 2200 50 1045 'A 1140 PSC 4.0/4.8 GPND /GPPD -017 175.0 87.5 140.0 80% 2530 51 1070 % 1140 PSC 4.5/5.8 GPND /GPPD -020 200.0 100.0 160.0 80% 2640 56 1000 .1A 1140 PSC 4.5/5.8 GPND /GPPD -022 225.0 112.5 180.0 80% 2700 61 950 % 1140 PSC 4.5/5.8 GPND /GPPD -025 250.0 125.0 200.0 80% 3100 60 980 'h 1140 PSC 4.5/5.8 GPND /GPPD-030 300.0 150.0 240.0 80% 4400 50 1100 (2)' 1140 PSC 8.0/8.8 GPND /GPPD -035 350.0 175.0 280.0 80% 5000 52 1150 (2)' 1140 PSC 9.0/10.8 GPND /GPPD - 040 400.0 200.0 320.0 80% 5300 56 1050 (2 1 1140 PSC 9.0/10.8 Note: 1. Ratings are shown for elevations up to 2,000 feet above sea level. Above 2,000 feet, input must be derated 4 percent for each 1,000 feet above sea level. 2. Standard motor is 115/60/1 totally enclosed. 3. SP = Shaded Pole; PSC = Permanent Split Capacitor 4. Unit amps are based on standing pilot units. Table 16-2 - Centrifugal Fan Gas Unit Heater Dimensional Data Outlet Motor Data Input MBh Output . Thermal Free Air Temp Velocity Nom Motor Speed Fla Models Max Min MBh Effic. Delivery Cfm Rise F Fpm Hp Type Avg Rpm Motor/Unit c GCND/GCPD-010 100.0 50.0 80.0 (80% 1200 62 880 Y. SPH 1725 5.0/5.8 GCND /GCPD-012 125.0 62.5 100.0 80% 1575 59 950 % SPH 1725 5.9/6.7 On GCND /GCPD-015 150.0 75.0 120.0 80% 1975 56 1030 'h SPH 1725 7.2/8.0 GCND /GCPD-017 175.0 87.5 140.0 80% 2300 56 1045 1 h SPH 1725 7.2/8.0 GCND /GCPD-020 200.0 100.0 160.0 80% 2400 62 965 % SPH 1725 11.0/11.8 GCND /GCPD-022 225.0 112.5 180.0 80% 2600 64 935 V. SPH 1725 11.0/11.8 GCND /GCPD.025 250.0 125.0 200.0 80% 2850 65 930 '/i SPH 1725 11.0/11.8 GCND /GCPD-030 300.0 150.0 240.0 80% 3950 56 1080 V. SPH 1725 11.0/11.8 GCND /GCPD-035 350.0 175.0 280.0 80% 4600 56 1090 1 CS 1725 14.0/14.8 GCND /GCPD - 040 400.0 200.0 320.0 80% 4800 62 1000 1 CS 1725 14.0/14.8 Note: 1. Ratings are shown for elevations up to 2,000 feet above sea level. Above 2,000 feet, input must be derated 4 percent for each 1,000 feet above sea level. 2. CS = Capacitor Start: SPH = Split Capacitor 3. Standard motors are 115/60/1 open drip - proof. 4. 02 maximum external static pressure. 5. Unit amps are based on standing pilot units. Table 16-3 - Centrifugal Fan Gas Unit Heater With Enclosure Performance Data Outlet Motor Data Input MBh Output Thermal Free Air Temp Velocity Nom Motor Speed Fla Models Max Min MBh Efficiency Delivery Cfm Rise F Fpm Hp Type Avg Rpm Motor/Unit GEND /GEPD-010 100.0 50.0 80.0 80% 1200 62 880 'h SPH 1725 7.2/8.0 GEND /GEPD-012 125.0 62.5 100.0 80% 1575 59 950 'h SPH 1725 7.2/8.0 GEND /GEPD-015 150.0 75.0 120.0 80% 1975 56 1030 V. SPH 1725 11.0/11.8 GEND/GEPD-017 175.0 87.5 140.0 80% 2300 56 1045 V. SPH 1725 11.0/11.8 GEND /GEPD-020 200.0 100.0 160.0 80% 2400 62 965 1 CS 1725 14.0/14.8 GEND /GEPD-022 225.0 112.5 180.0 80% 2600 64 935 1 CS 1725 14.0/14.8 GEND /GEPD-025 250.0 125.0 200.0 80% 2850 65 930 1h CS 1725 16.4/17.2 GEND /GEPD -030 300.0 150.0 240.0 80% 3950 56 1080 1h CS 1725 16.4/17.2 GEND /GEPD-035 350.0 175.0 280.0 80% 4600 56 1090 11/2 CS 1725 16.4/17.2 GEND /GEPD - 040 400.0 200.0 320.0 80% 4800 62 1000 2 CS 1725 24.6/25.4 Note: 1. Ratings are shown for elevations up to 2,000 feet above sea level. Above 2,000 feet, input must be derated 4 percent for each 1,000 feet above sea level. 2. CS = Capacitor Start: SPH = Split Capacitor 3. The GEND/GEPD is not rated by AGA as a unit. The unit is approved as a centrifugal fan gas unit heater. The enclosure is not AGA approved. ii: 4. Standard motors are 115/60/1 open drip - proof. • 5. Unit amps are based on standing pilot units. 6. 0.2" maximum external static pressure. 16