Loading...
Correspondence : Aft WASHINGTON 4 COUNTY, I, i 1% .. OREGON October 23, 1997 / nn) (V./ Loy Taylor McDonald's Corporation 5000 SW Meadows Lake Oswego, OR 97035 RE: ! ::. :'.. 31 - -.., - - 11201--SW 72nd S • 4 Al ( - ' Tigard, OR 97223 Dear Mr. Taylor: The Washington County Department of Health and Human Se vices has obtained the plans for the proposed McDonald's to be located at 11201 SW 72nd St et in Tigard, Oregon. 4ve M (,(. It is our understanding that community water and community sewer will be utilized at this structure. The following is understood to be planned with necessary changes and conditions for approval noted: 1) The plans show a commercial dishwasher. Machine or water line mounted thermometers must be provided to indicate water temperatures of the wash and rinse cycles. These thermometers must be accurate to ±3 °F. The dishwasher must be capable of reaching proper wash and rinse temperatures. If chemical sanitizers are used, they must meet the requirements of 21 CFR and be dispensed in proper concentration. An accurate test kit is required to test sanitizer concentration of the final rinse. 2) The plans also show a three compartment sink unit to wash, rinse and sanitize utensils in. Each compartment of the three compartment sink unit must be large enough to totally submerse your largest multi -use utensil. Two drainboards are required. One drainboard must be designated for soiled utensils and the other for clean utensils. An accurate test kit is required to test sanitizer concentration in the third compartment of your sink. Department of Health & Human Services 155 North First Avenue Hillsboro, Oregon 97124 WIC Nutrition Plan: (503) 640 -3555 Administration & Planning: (503) 693 -4402 TDD: (503) 648 -8601 Health Services: (503) 648 -8881 FAX: Clinic 693 -4522 / Administration 693 -4490 Environmental Health: (503) 648 -8722 Page Two 3) The plans show a vegetable sink in the preparation area. Please be aware that this sink can not be utilized for noncompatible uses such as handwashing or mop washing. This sink must waste indirectly to a floor sink. 4) The plans show a utility mop sink. Please supply a mop hanging device so mops and similar floor cleaning equipment can be cleaned and hung between uses. 5) A handsink must be designated in each of the food or drink preparation and food or drink dispensing areas. Handsinks are shown in the front and back preparation areas. 6) All handwashing sinks including the restroom handsinks must be equipped with dispensed soap and dispensed sanitary towels or approved hand drying devices. Common (cloth) towels cannot be used to dry hands. If disposable towels are used, easily cleanable waste receptacles must be conveniently located near the handwashing facilities. The handwashing sinks must be equipped with hot and cold tempered water. If self - closing, slow- closing, or metered faucets will be used, they must be designed to provide a flow of water for at least 15 seconds without the need to reactivate the faucet. 7) Two restrooms are shown with a total of three toilets, one urinal, and two handsinks. This number of fixtures is adequate for an occupancy of 100. 8) The restrooms must meet all the requirements as described in the 1987 Oregon Food Sanitation Rules for design, construction and operation. Be aware that restroom doors must self -close and that there must be at least one covered waste receptacle in the women's restroom. 9) The dishwasher, food preparation sink, ice maker, ice bins, soft drink equipment and any other piece of equipment utilized to hold food or ice in that is equipped with a drain must waste indirectly. Where air gaps are required, the distance between the bottom of the waste pipe and the top of the floor sink or drain must be at least one inch or two waste pipe diameters whichever is greater. 10) The plans show a washing machine. The rules require that a dryer be installed in establishments that have washing machines. 11) Any refrigeration unit which does not come equipped with an evaporator pan for its liquid wastes must have its liquid wastes drain indirectly to a floor drain or floor sink. 12) Floor sinks and floor drains must be located so they are accessible for cleaning and maintenance. 13) All floor, wall and ceiling surfaces must be smooth, durable, sealed and easily cleanable and in a light color. n Page Three 14) Where walls and ceilings are painted, high gloss paint is recommended. It is also highly recommended that walls behind cooking and dishwashing equipment and the mop sink be covered with durable, washable backsplash. 15) If acoustical ceiling tile are utilized and they become soiled and can not be cleaned then replacement will be required. A washable ceiling surface is recommended for food preparation and cooking areas. .16) Self - service salad /condiment areas must have a smooth, nonabsorbent floor covering such as vinyl, tile or the equivalent extending 30 inches on each side to which the public has access. 17) The plans submitted show a self - service beverage area. Please be aware that beverage drinking containers can not be refilled on dispensing units that require the container to come into contact with the beverage machine. The lip of used beverage containers should never come in contact with a beverage dispensing unit or an ice dispensing machine. 18) Base coving at least four inches in height will be needed on all wall /floor junctures that require wet mopping. 19) Any gaps in floors, walls, or ceiling around plumbing or electrical work must be filled in to prevent rodent and insect access and entrance. 20) Exposed utility lines and pipes can not be installed horizontally on the floor. 21) All lamps over or within food storage, food preparation, and food display facilities and facilities where utensils and equipment are cleaned and stored shall be shielded, coated or otherwise shatter resistant. 22) Each refrigeration unit not equipped with an accurate built -in thermometer, must have a spirit stemmed thermometer located on the top shelf or door. 23) A metal probe thermometer accurate to ±2 °F must be provided to assure attainment and maintenance of proper internal cooking, holding or refrigeration temperature of potentially hazardous foods. 24) Each hot holding facility storing potentially hazardous food shall be provided with a numerically scaled indicating thermometer accurate to ±3 °F, located to measure the air temperature in the coolest part of the facility and located to be easily readable. Recording thermometers, accurate to ±3 °F, may be used in lieu of indicating thermometers. Page Four 25) Where it is not practical to install thermometers on equipment such as bain - maries, steam tables, steam kettles, heat lamps, cal -rod units, or insulated food transport carriers, then the product thermometer must be available and used to check internal food temperatures. 26) If perishable foods will be reheated, a method to reheat this food to 165 °F within one hour must be provided. Steam tables, bain maries and crock pots are not allowed for rapid reheating or cooking of foods. 27) If perishable food will be cooled then a method to rapidly cool this food must be provided. Commercial air cooled refrigerators or ice baths are recommended for cooling foods. When foods are cooled in the refrigerator, they must be cooled in shallow containers. Liquid foods may not be cooled at a depth of greater than four inches and soft thick foods may not be cooled at a depth greater than two inches in air cooled refrigerators. Perishable food must be cooled from 140 °F to 45 °F or less in no more than four hours. 28) All equipment must be installed so as to be moveable or properly sealed to facilitate proper cleaning. 29) Storage shelves must be smooth, impervious, and easily cleanable. Unfinished wood is not acceptable. 30) To minimize manual contact of foods, please provide and utilize handled scoops and other appropriate utensils. 31) Food may not be stored under exposed or unprotected sewer lines or water lines, except where automatic fire protection sprinkler heads may be required by law. 32) All storage of food, food containers, and single service utensils must be on shelves at least six inches above the floor except where storage is on wheeled platforms or four inch high sealed bases. Metal pressurized containers need not be elevated. 33) All floor mounted equipment, unless readily movable, must lie sealed to floor, installed on a concrete or otherwise smooth base at least four inches high, or elevated on legs to provide at least a six inch clearance between the floor and equipment. 34) Be aware that all food or food items in the facility which are within customer reach and are not prepackaged, must be protected from customer contamination by a sneeze shield or other approved means. Please see the NSF pamphlet that is enclosed for information on sneeze shield requirements. 35) If food delivery is planned then deliveries must be made in approved company vehicles with approved equipment that will keep products at proper temperatures. Page Five 36) Outside storage areas or enclosures must be large enough to store the garbage and refuse containers and must be kept clean. Garbage and refuse containers, dumpsters and compactor systems located outside must be stored on or above a hard, nonabsorbent surface such as cement or machine -laid asphalt that is kept clean and maintained in good repair. 37) Your plans show seating for more than 30 patrons and will need to conform with the Oregon Clean Air Act designating smoking and nonsmoking areas. For your convenience, a copy of this Rule is enclosed. 38) A grease trap is shown. A maintenance schedule must be developed and followed to prevent grease from going down the sanitary sewer. 39) All plumbing must meet the requirements of the City of Tigard and the Oregon Uniform Plumbing Code. 40) This facility and its operation must meet all the Oregon Food Sanitation Rules and Statutes. 41) All employees must have current Washington County Food Handler's Cards. For information call 640-3460. 42) A preopening inspection must be conducted by our Department prior to license approval and operation. Please contact Tim Bunnell at 648 -8722 at least one week prior to operation to schedule this inspection. A revision showing a dryer is required for final approval by this Department. Sincerely, DEPARTMENT OF HEALTH AND HUMAN SERVICES Toby H ris, R.S., M.P.H., Supervisor Environmental Health and Sanitation TH:lkg Enc: cc: Tim Bunnell Branden Taggart From: Jami Hendrickson [hp @cni.net] Sent: Wednesday, October 29, 2008 3:47 PM To: Branden Taggart Subject: Permit Change Information Branden, The fees should be good, I just need to have you update the a hand sink and delete a floor sink on the plumbing permit. The sewer permit shows three new 2 inch lines which should be perfect. PLM2008 00407, 11201 SW 72nd. Ave 1. Plumbing permit needs to be updated. Instead of three 2 inch floor sinks it should be 2. a. 2 - 2 inch floor sinks b. 1 - 3 inch floor sink - a replacement c. hand sink 2 inch drain Let me know if you have any questions, Thank you for your help, Jami Hendrickson 1