Loading...
Report Main Office Salem Office Bend Office P.O. Box 23814 4060 Hudson Ave., NE P.O. Box 7918 Tigard, Oregon 97281 Salem, OR 97301 Bend, OR 97708 Inc one (503) 684 -3460 Phone (503) 589 1252 Phone (541) 330 -9155 a r l g l i • FAX (503) 684 -0954 FAX (503) 589 -1309 FAX (541) 330 -9163 JUL 1 0 2000 Moisture - Density Relationship Permit No.: 2000 - 00018 • B nc - Andy Cartales 07/05/00 Project: Delta Fire Retaining Wall - Const Monitoring Job Number: G0001590 Material Type: Native Light Brown Silt Location: On - Site (Bottom of Cut) Test Method: ASTM D -1557 A, C -136, D -2216 Date Sampled: 06/28/00 Sample Method: ASTM D -75 Date Tested: 06/29/00 Preparation Method: Moist Oversized Material: Removed Compacting Method: Manual Hammer Type: Circular 107 • • 106 105 104 c , p 103 102 101 100 15 16 17 18 19 20 21 22 Moisture Content ( %) Zero Air Voids Line = 2.600 Optimum Moisture: I 17.9% I Max. Dry Density: I 104.5 I Ibs /ft' Percent Passing #4 Sieve: 98.7% cc: City of Tigard - Robert Poskin Reviewed By: Our reports pertain to the material tested /inspected only. Information contained herein! of to be reproduced, except in full, without prior authorization. 06/30/00 FRI 11:08 FAX 503 670 9147 CARLSON TESTING ``1 0 0001 J ` -)00 /,/ C arlson Geotechnical Mein office Salem Office Bend Office P.O. Box 23814 4060 Hudson Ave,, NE P.O. BoX 7918 A Division of Carlson Testing, Inc. Tigard, Oregon 97281 Salem, OR 97301 Bend, OR 97708 Geotechnical Consulting Phone (503) 684 -3460 Phone (503) 589 -1252 Phone (541) 330 -9155 Construction Inspection and Related Tests FAX (503) 670-9147 FAX (503) 589 -1309 FAX (541) 3.30 - 9163 uric 30, 2000 CGT No. G0001590 Permit No. 2000-000 FIELD OBSERVATION REPORT PROJECT: Delta Fire ADDRESS: 14795 SW 72 Tigard BY: Jeanne M. Niemer, PE WEATHER: Sunny and Warm PURPOSE OF VISIT: Construction Monitoring Arrived on site at 1000, per the request of Don of Anderson Construction. Met with the earthwork contractor on site. While on site, I observed the condition of the subgrade for the proposed retaining wall. The subgrade consisted of stiff to hard native silt. I probed the subgrade using a one -half inch steel rod, and was unable to penetrate the subgrade more than about 1 /2 inch in any location. Based on the results of my observations, the retaining wall subgrade has been prepared in accordance with the plans, specifications and our recommendations. Left site at 1015 J - - ne M. Niemer, P.E. Prin •pal Geotechnical Engineer • •te: Our reports pertain to the locations observed at the time of our visit only. Information contained herein is not to be reproduced, except in full, without prior authorization from this office. DISTRIBUTION Andy Cartales, Delta Fire: 620.1058 City of Tigard: 684.7297 doc id: delta fireffr063000 C arlson Geotechnical _ Main Office Salem Office Bend Of/ice P .O. Box 23814 4060 Hudson Ave., NE P.O. Box 7918 A Division of Carlson Testing, Inc. Tigard, Oregon 97281 Salem, OR 97301 Bend, OR 97708 Geotechnical Consulting Phone (503) 684 -3460 Phone (503) 589 -1252 Phone (541) 330 -9155 Construction Inspection and Related Tests FAX (503) 670 -9147 FAX (503) 589 -1309 FAX (541) 330 -9163 August 14, 2000 FILE C�P Andy Cartales Delta Fire, Inc. PO Box 4101 Tualatin, Oregon 97062 -4010 Geotechnical Letter of Compliance Delta Fire Retaining Wall 14795 SW 72n Avenue Tigard, Oregon CGT Proj: G0001590 Carlson Geotechnical has served as geotechnical engineer of record for the retaining wall at the Delta Fire site in Tigard, Oregon. As geotechnical engineer of record, Carlson performed footing subgrade observations, and observation and testing of backfill compaction during construction. Based on the results of our observations, all earthwork was completed in general accordance with the plans, specifications, and our recommendations. We provided field reports to the design and construction team, as well as to the City of Tigard during construction. Additional copies of our reports are available in our office, if needed. Please contact us if you have any questions. Sincerely, CARLSON GEOTECHNICAL ;4\)_Pfifikei; . - 1' - #156484 Jean e M. Niamer, •.E. : Prin pal Ge echnical Engineer �?� ��� I OTIKS: t2.3t . co 1 Doc. ID: Delta Fire /comp letter