Report ' Construction In & Related Tests . arlson Vesting, Inc. GeotechnicalConsulting P.O. Box 23814 )B NO. 97-3539 Tigard, Oregon 97281 , 199F: Phone (503) 684 -3460 REPORT OF IN -PLACE DENSIT TES F TS FAX (503) 684 -0954 :Iient IA •. - \ . . - - A - -. Permit Ni:' . SIT97- 001 /t- - :UF' '7 -03S_' 'roject u A . - _ ■ ^ - _ • -' 11201 SW 72ND - TIGARD OR .laterial Description 2./.4."-0 ROC': FROM TIGARD SAND u, GRAVEL lax. Dry Density 122 - Ibs. /cu. ft. Optimum Moisture 1 =: - 7 % Method of Test ririSHTO T ASTM D2922 ;tar,d r Count Density: Moisture: Serille 341:)/'2cs::=: _ DATE OF TEST % ADJ. ELEV. FIELD IN -PLACE DENSITY % TEST LOCATION COARSE MAX. MOISTURE (LBSJCU.FT.) TEST NO DEPTH PARTICLES DENS. FT. % WET DRY COMPACTION 13C 25' ' FRO_IM THE SOUTH END - TOP -- --- 4 6-18 6. 134.4 126 1M+ )C)+ BC: 75' FROM THE SOUTH END TOP 5 6-18 7.6 1 2(x . 1 1 / . :3 , . /Fi BC: 125' FROM THE SOUTH END TOP r 6-18 8.1 1:30.2 120.4 • aemarks: Density & Moisture Counts 95I REGIUIRED BC: 4 =c: CITY CIF TIGARD BUILDING DEPT BC: 5 YOUNG ELECTRIC SIGN BC 6 P PE TECHNICAL DIRECTOR rested by ( _ C0r IPER /CPW Rev i ewect By CARLSON TESTING INC. 'df('>tcnariSPantalneMel> `is b r 4r62uc F, dt keltw oZF'PRor'ia izaRrdrlYrbm this office. Page No. 1 CASE HISTORY FOR CASE NO.: SIT97 -0013 MCDONALDS CORPORATION 11201 SW 72ND AVE 02/12/98 Action Description Req/ Schd/ End/ Action Notes Disp By Update Upd Code Sent Done Done Date By SITC005 Application received / / / / 05/05/97 RECD DRA 07/07/97 DRA SITC008 Permit Created / / / / 05/05/97 PASS BON 07/07/97 DRA SITC010 Check for prcl. restrict. / / / / 05/05/97 Conditions of approval for a \SDR97 -0001 PEND BON 07/07/97 DRA apply. SITC011 DST /mail Land Use Condition Lt / / / / 05/05/97 SENT BON 07/07/97 DRA SITC013 Plans Routed to Plans Examiner / / / / 05/05/97 PASS BON 07/07/97 DRA SITC015 Plan Rev. Ltr Sent to Ofc Svcs / / / / 05/06/97 JHF 07/07/97 DRA SITC018 Revised Plans Received / / / / 06/23/97 Everything in except decision on JHF 07/07/97 DRA placement of fire hydrant 6/26/97 SITCO26 Plans approved by CPE / / / / 06/26/97 APPR JHF 07/22/97 JHF SITCO30 Reviewed plans routed to DSTS / / / / 06/26/97 APPR JHF 07/22/97 JHF SITCO32 DST Post - Review Completed / / / / 07/07/97 On hold till approval from planning & PASS DRA 07/22/97 JHF engineering on SDR97 -0001. Needs to identify contractor. SITC080 (F) Ready to issue / / / / 07/30/97 PASS DRA 07/30/97 DRA SITC092 (F) Issue permit / / / / 07/30/97 PASS DRA 07/30/97 DRA SITC700 Erosion Control 07/07/97 / / / / 10/28/97 J *H SITC702 Excavation Insp 07/07/97 / / 10/28/97 I guess the check mark means that the PASS TLP 10/28/97 J *H report was received. SITC710 Fill Inspection 07/07/97 / / 10/28/97 PASS TLP 10/28/97 J *H SITC720 Grading Insp 07/07/97 / / 10/28/97 PASS TLP 10/28/97 J *H SITC740 Strm Drain Insp 07/07/97 / / 10/16/97 PASS TLP 10/17/97 J *H SITC750 San Sewer Insp 07/07/97 / / 10/16/97 PASS TLP 10/17/97 J *H SITC757 Domestic water line inspect. 07/07/97 / / 10/16/97 note: TVW PASS TLP 10/17/97 J *H SITC773 Reinforced concrete final rept 07/07/97 / / 10/28/97 I guess the check mark means he received PASS TLP 10/28/97 J *H the report. SITC775 Engineered grading final reprt 07/07/97 / / 10/28/97 I guess the check mark and approved PASS TLP 10/28/97 J *H circled means this was completed. SITC799 Final Inspection / / / / 06/26/97 Hold for location and installation of PASS JHF 10/28/97 J *H fire hydrant. Fire flow analysis provide by interface engineers, 7/17/97 OK Site work approved - final TLP, 102897 SITC800 Case Finaled / / / / 10/28/97 PASS TLP 10/29/97 J *H