Correspondence (153) He WESTECH ENGINEERING, INC. k 9 /. 7- -000/3 CONSULTING ENGINEERS & PLANNERS 1' June 20, 1997 RECEIVED Mr. Jim Funk JUN 2 3 1997 Plans Examiner City of Tigard Cf1oe 13125 SW Hall Blvd. Tigard, OR 97223 RE: Site Plan Review, McDonald's Restaurant - Highway 99 & 72nd J.O.# 1742.057.0 Dear Mr. Funk: We have reviewed the submitted site plan review comments and have revised the site plan and civil drawings accordingly. Following is our response to each comment and action taken: Site Work 2. The site is not proposed to be divided. The McDonald's site is a leased site. The . property lines shown are lease lines. The entire property is shown on the survey. 3. The house shown on the site plan and civil drawings was removed after the survey was completed. We have removed the house and garage from the drawings. We do not know who removed the structures. 4. The total square footage of the site is as follows: Total Area Disturbed: 66,407 s.f. Total Area Leased: 39,885 s.f. • Impervious Area: Within lease area: 32,010 O. • Total 37,622 s.f. Landscaped Area: • Within lease area: 7,875 s.f. Total 28,785 O. 5. The total cubic yards of material excavated, filled or relocated are as follows: Excavated and removed from site: 3,000 c.y. Excavated and relocated on site: 3,600 c.y. Imported fill material: 4,400 c.y. The totals shown have been provided from the contractor. 3841 Fairview Industrial Dr. S.E., Suite 100, Salem, Oregon 97302 Phone: (503) 585 -2474 Fax: (503) 585 -3986 June 20, 1997 Mr. Jim Funk Page 2 7. Clean outs have been included on the drawings at 100' intervals. The existing waterline, which is shown to the north of our building is being relocated. The engineered drawings have been submitted, reviewed, and approved by Tualatin Valley Water District. Number 8 of the Notice of decision required additional right of way be granted to the City to provide for a 40 R.O.W. from centerline to property line. This additional R.O.W. has been shown on the drawings and the building set accordingly. 9. No retaining walls are shown or proposed for this project. lg. P P P J The detention pond is drained through an area drain at the bottom of the pond as shown on the civil drawings. See Storm Water Detention and Water Quality Detail Au , on Sheet 3. Fire and Safety 2. We have submitted the drawings to Tualatin Valley Fire and Rescue (TVFR) review. Mr. Gene Burchill, from TVFR is reviewing the drawings for placement of a fire hydrant, if required by TVFR. Once we receive Mr. Burchill's comments we will revise the drawings accordingly. We anticipate receiving his comments the week e . - - 7. This concludes our comments. As requested, we are resubmitting 4 sets of revised drawings for your review. If you have any questions or need any additional information regarding this project, please contact us at (503) 585 -2474. Sincerely, WESTECH ENGINEERING, INC. Chris G. Budeski \ cgb cc: Loy Taylor, McDonald's Corporation