Loading...
Correspondence (152) June 11, 1997 CITY OF TIGARD John Miologus OREGON 711 Jorie Blvd. Oak Brook, IL 60521 RE: McDonald's Corp. Site Plan Review . 11590 SW Pacific Hwy PC #: 5-5c SIT #: 97 -0013 j The following items remain unresolved from our itAa77 T39 plan review. Paragraph numbers correspond with those not resolved. K .u y :TM i ,? Y Wi °� ,o a1 s :<c.�FPt:� 4 Y r ` „ tT* u r a �'..�a.�L . 4 d v ,,A ;:v Y.i _ ?i •; '+ _... .il'F,�,. � Y�' ' A : . #7,8,9, and 11 Statements in your June 3, 1997 response letter refer to Westech Engineering. To date we have not received revised plans. - / #10 The structural calculations from Young Electric must be stamped by an engineer licensed by the State of Oregon. • \�. U v ‘0 1 The UFC, Section 1103.2.2 clearly identifies walls of combustible construction. Provide proper clearance of non combustible walls. Walls exceeding 6 feet � 'v require site design approval and a structural review. Provide engineering. #2 Again, we have not had any correspondence from Weste Engineering. No-i e - L o/ oC(- 710 , t`k ) -iv // Please submit four copies of revised submittal documents and a letter indicating your response to the above comments for review. Please call me at (503) 639 -4171 if you have any questions. Sincerely, Jim Funk PLANS EXAMINER c: Anthony Spata Westech Enginerring 711 Jorie Boulevard 3421 - 25th St. SE Oak Brook, IL 60521 Salem , OR 97302 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772 r t`il '• May 7, 1997 ��:. �_ I _1. John Miologos CITY OF TIGARD 711 Jorie Blvd. Oak Brook, IL 60521 OREGON RE: McDonald's Corp. Site Plan Review 11590 S.W. Pacific Hwy PC#: 5-SC S #: 97 -0013 �) Submittal documents for the above referenced project have been reviewed for conformance with the applicable 1996 Oregon Specialty Codes and other applicable codes and standards. The following comments are noted: In seismic Zone 3 the potential for seismically induced soil Liquefaction and soil instability shall be evaluated [OSSC Section 1804.2] A. Provide an addendum to the Geotech report addressing the requirements of OSSC Section 1804.5. The proposed project site consists of more than one parcel of land. There shall be no - underlying land divisions unless the buildings are designed for location to property lines. Provide a true copy of the recorded document describing the site as one parcel. A Demolition Permit is required if the existing house is to be raised. - A y Provide the total square footage of impervious area. Include roofs, sidewalks, parking lot, play grounds and gravel areas. ?AU/0 A, Provide the total cubic yards of each of the following: A. Excavation 4 " G ' - B. Fill [structural and non - structural](/ `'". V A Complete the enclosed Soils Special Inspection form designating an Approved Testing Laboratory [Line B] and signed by the owner of the project [Line 0]. The completed form must be returned to this office before a Site permit can be / issued. BV Copies of all special inspection reports shall be filed with this office continually uring construction [OSSC, Section 3305]. A final signed report must be on file before an occupancy certificate will be issued [OSSC, Section 3318]. 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772 McDonald's Corp. Site Plan Review PC#: 5-5C SIT #: 97 -0013 Page #2 to 1 k / ig—/ Cleanouts are required on all drainage piping every 100 feet and at each aggregate � change of direction exceeding 135 degrees (OPSC, Section 707.4 and 707.51. G /1/. ' 6iL The revised drawings shall include the relocation of the building as/if required by the location of existing utilities. 6- 31-) The location of retaining wall and their design specifications shall be dearly illustrated in the revised plans. Submit the engineers calculations for retaining walls exceeding 4 feet in he ht. r Submit the engineers design calculations for all signs/menu boards over six feet high. ./ , (SHT-S/D -4). 't, How are you draining the detention pond? 1 ,. S designating accessible parking stalls shall be mounted 7 feet above finish grade / S ' �, [OR20 -6D -OUT] i k dr 1. A trash dumpster with a capacity of 1.5 cubic yards or greater shall not be located under 6 '`v or within 5' of combustible construction (UFC, Section 1103.2.21. 2. No portion of the building shall be located more than 250 feed from a fire hydrant. • A. Provide not less than one fire hydrant and illustrate on the revised plan. Please submit four copies of revised submittal documents and a letter indicating your response to the above comments for review. Please call me at (503) 639 -4171 if you have any questions. Si ly, Jim Funk PLANS EXAMINER c: Anthony Spata Westech Engineering 711 Jorie Boulevard. 3421 25th St. S.E. Oak Brook, II 60521 Salem, OR 97302 m.pprtnsysldocumentlsit97 00.131pc5 -5c.doc • _ Plan Review * 4 4 4. Date 5.--h /4 CITY OF TIGARD OREGON Soils Special Inspections This form shall be signed by the Owner, Engineer or Architect of Record and returned to the Building Division prior to issuance of the permit. Please note that a separate structural special inspection form may be required. Project Address: // f 9v l A, 69e e/ L 7,1 _ Project Name: 2'7e I'-7.4L Architect of Record (Finn): S p h h 7r1 / o L o . U 1 Phone: G 30 - 2 7 - z g Z; Engineer of Record (Finn): A},v � Az Al , ,. -, . Phone:. 7O _i L 3 - f'2 Y Soils Engineer: A/ON G re f rNv Frm: Phone: Lot Subdivision: rhe following special inspections shall be performed according to the State Building Code and City of Tigard's Municipal :ode Chapter 14.06.010 - 14.06.040: Tel Engineered Grading ( >5,000 cubic yards) - U.B.C. 3309.4 ❑ Regular Grading - U.B.C. 3309.8 Compaction Reports (per ASTM standards listed in U.B.C. 3305) Testing Agency: Phone: ❑ Other he owner hereby agrees to employ the above soils engineer for the above -noted special inspections. signature of Owner 'rint Name Phone No. Date mzecavosaustroc 25 SW HcII Blvd., licrd, CR 97223 (503) 639 -4171 TCO (503) 684 -2772