.12-03 -1999 10:2dAM FROM CAPITOL ELECTRIC 2551966 P.2
Project: TIGARD CORP. BLDG. B Page: 1
Form 2a 12/03/99
SUMMARY
I 1
PROJECT 1 1. Project game TIGARD CORP. BLDG. B
2. Address • 12259 SW 69Th AVE.
1 3. City /town TIGARD, OR. 91223
1 4. Building Area (ft2) 41,070
1 5. County WASHINGTON
1 6. Number of floors 2 i
t t
Chapter Type I.D. Description Attached
ATTACHED Building Form 3a Envelope -- General [ ]
3b Prescriptive Path -Zone 1 [ 1
FORMS AND 3C Prescriptive Path -Zone 2 1 1
3d Simplified Trade -off [ ]
WORKSHEETS Envelope
Worksheet 3a Wall U- values [ ]
3b Roof U- values [ 1
. 3C Floor U- values [ 1
Systems Form 4a Systems -- General ( l
Form 4b Complex Systems
Worksheet 4a Unitary Air Conditioner- - Air Cooled 1 1
4b Unitary Air Conditioner -- Water Cooled [ 1
4c Unitary Heat Pump- -Air Cooled 1 1
4d Unitary Heat Pump- -Water Cooled 1 1
4e Unitary AC & Heat Pump -- Evaporatively Cooled [ ]
4f Packaged Terminal AC - -Air Cooled [ ]
4g Packaged Terminal Heat Pump- -Air Cooled [ 1
4h Water Chilling Packages - -Water & Air Cooled 1 1
4i Boilers -- Gag -Fired and Oil -Fired 1 ]
• 4j Furnaces & Unit Heaters - -Gas- and Oil -Fired 1 1
Lighting Form 5a Lighting -- General
[y']
5b Interior Lighting Power -- Occupancy [ ■]
5c Interior Lighting Power- -Space [ ]
Worksheet 5a Lighting Schedule [i]
5b Interior Lighting Power [ ✓)
5c Interior Control Credits 11]
1
(503) 255-9488
e
APPLICANT 7. Name y RICHARD MARTIN 10.Tel
� P `
B. Company { CAP /TOL ELECTRIC CO.,INC 1 11. Date 12/03/99
f t '
9. Signature
I 1
, 12/Q3/99 15:34 FAX 15032212077 LRS ARCHITECTS. INC. Z003
.12 -03 -1999 10:25AM FROM CAPITOL ELECTRIC 2551966 P.3
Project: TIGARD CORP. BLDG. B Page: 1
Form 5b
INTERIOR LIGHTING POWER - Occupancy Method 12/03/99
1 i
I r (b) f (c) i ( d) (e) (f) (g)
Retail or (a) Max Lighting
Mer Floor Power Power
dige Area Allow. Budget
power
Lighting Group Area
bigh (f (W /ft2) (c -d) x e + f
(Group M) F
If area is less than 0
2,000 ft2, enter 0 0 3.4 0
area in (e)
If area is between
2,000 and 6,000 ft2 2,000 2.5 6,800
enter area in (c)
If area over
6,000 ft2, enter 6,000 1.7 16,800
area in (c) 1 1
i 1 1 i
i T I 1 - 1
Uses (a) I (b) (c) (d) (e) (f) (g)
Other Max Lighting
Than Ceiling Floor Power Power
Group M height Area Allow. Budget
Power Group occupancy Use (ft2) (W /ft2) (c -d) x e + f
(Group M 44, 284
B OFFICE undex15 41,070 1.2
F 1 1 1 1 1
1. Total Interior bighting Power Budget (W). 49,284
i
2. Sum the page total (s) from Worksheet 5b 40, 389
I
3. Total lineal feet of track lighting I 0
i
4. Multiply line 3 by SO 0
5. Total Interior Lighting Power (line 2 and 4) 40,389
6. Total Control Credit from Worksheet Sc 0
7. Total Adjusted Lighting Power (W) (line 6 - 5) 40,389
i
8. Does design meet the budget? Otherwise redesign Yes
1 1
, 12/03/99 15:34 FAX 15032212077 LRS ARCHITECTS, INC. 0004
12-03 -1999 10 :25AM FROM CAPITOL ELECTRIC 2551966 P.4
•
Worksheet 5a
Project: TIGARD CORP. BLDG. 3 Page: 1
LIGHTING SCHEDULE 12/03/99 (0 ) (d) (e) (f)
•
(a) i (b) - Lamp Ballast 1 Tab
�Luminaire 5b
Lum -� Fixture
ID 1 DescriptioA No. Description No.IDescript. 1 Power "x"
3 F32T8 1.0 ELECT 90
A 12X4 TROFFER 1
REM 12X4 TROFFER
3 F32T8 1.0 ELECT 90 •
A 3 12X4 TROFFER 3 F32T8 1.0 ELECT 90
C 11X4 WRAP 3 F32T8 1,0 ELECT 90
D (STRIP 1 F32T8 1.0 ELECT 42
1 ---- I
D2 1STRIP 1 F32T8 1.0 ELECT 42
FEM 14 WALL 2 F32T8 1.0 ELECT 71
G (STRIP 2 F32T8 1.0 ELECT 71
H `RECESSED 1 26W TRIPPLE 1.0 ELECT 37
J RECESSED 1 3 2W TRIPPLE 1.0 ELECT 4
JEM 1RECESSED 1 32W TWIN 1.0 ELECT 46
K RECESSED 1 13W TWIN 1.0 ELECT 1
KEM RECESSED 1 13W TWXN 1.0 ELECT 17
L SURFACE HID
1 250W PAY 1.0 MAGNETIC 240
Q RECESSED 1 42W TRIPPLE 1.0 ELECT 60
Q M RECESSED 1 42W TRIPPLE 1.0 ELECT 60
T . f 1
_ 1 } i 1 ---- 1
• 1 1 i 1 • 1 1
t
, 12/p3/99 15:35 FAX 15032212077 LRS ARCHITECTS, INC. a()05
.12- 03-1999 10:26AM FROM CAPITOL ELECTRIC 2551966 P_5
Worksheet 5b
Project; TIGARD CORP. BLDG. B Page: 1
12/03/99
INTERIOR LIGHTING POW=
(a) (b) (c) (d) (e) (f)
Lighting
•
Room or Room or Plans Luminaire Quantity of Luminaire Power
Sheet No. Designation ID Luminaires Power (d) x (e)
E2 /E3 1ST /2ND FLOOR LIGHTING
A 307 90 27,630
E2 /E3 1ST /2ND FLOOR LIGHTING
ABM 49 90 4,410
E2 /E3 1ST /2ND FLOOR LIGHTING
8 5 90 450
E2 /E3 1ST /2ND FLOOR LIGHTING C 3 90 270
E2 /E3 1ST /2ND FLOOR LIGHTING3 D 24 42 1,008
E2 /E3 1ST /2ND FLOOR LIGHTING D2
2 42 84
E2 /L3 1ST /2ND FLOOR LIGHTING FEN 8 7 1 568
E2 /E3 1ST /2ND FLOOR LIGHTING G 3 71 213
E2 /E3 1ST /2ND FLOOR LIGHTING H 16 37 592
• E2 /E3 1ST /2ND FLOOR LIGHTING J 36 46 1,656
E2/23 1ST /2ND FLOOR LIGHTING JEM 13 46 59B
F 24 17 408
E2 /E3 1ST /2ND FLOOR LIGHTING K
L2 /E3 1ST /2ND FLOOR LIGHTING KEM 6 17 102
E2 /E3 1ST /2ND FLOOR LIGHTING L 4 240 960
E2 /E3 1ST /2ND FLOOR LIGHTING Q 10 60 600
E2 /E3 1ST /2ND FLOOR LIGHTING QEM 14 60 840
I
•
1 1
1. Page Total. Sum the amounts in column (f) 40,389
i
12/03/99 15:35 FAX 15032212077 LRS ARCHITECTS, INC. a008
12- 03_1999 10 :26AM FROM CAPITOL ELECTRIC 2551966 P.6 •
•
Project: TIGARD CORP. BLDG. C Page: 1
Form 2a 12/03/99
SUMMARY
PRO3ILCT 1. Project name
TIGARD CORP. BLDG. C
2. Address 12447 SW 69TH AVE.
3. City /town TIGARD, OR. 97223
4. Building Area (ft2) 41,070 .
5. County WASHINGTON
6. Number of floors 2
1
r
Chapter Type I.D. Description Attached
ATTACHED Building Form 3a Envelope -- General ( 1
3b Prescriptive Path -Zone 1 I 1
FORMS AND 3c Prescriptive Path -zone 2 I I
3d Simplified Trade -off [ 1
•
WORKSHEETS Envelope
Worksheet 3a Wall U- values . 1 1
3b Roof U- values ( 3
3c Floor U- values 1 1
Systems Form 4a Systems--General ( 1
Form 4b Complex Systems 1 1
Worksheet 4a Unitary Air Conditioner - -Air Cooled ( 3
4b Unitary Air Conditioner- -Water Cooled ( 1
4c Unitary Heat Pump- -Air Cooled ( 3
4d Unitary Heat Pump- -Water Cooled ( 1
4e Unitary AC & Heat Pump-- Evaporatively Cooled ( 1
4f Packaged Terminal AC - -Air Cooled ( )
4g Packaged Terminal Heat Pump- -Air Cooled 1 1
4h Water,Chilling Packages - -Water & Air Cooled 1 1
4i Boilers -- Gas -Fired and Oil -Fired 1 3
4j Furnaces & Unit Heaters- -Gas- and oil -Fired 1 1
Lighting Form Sa Lighting -- General 111
5b Interior Lighting Power -- Occupancy 111
Sc Interior Lighting Power - -Space 1 1
Worksheet Sa Lighting Schedule (d1
5b Interior Lighting Power I ✓1
Sc Interior Control Credits ( ✓1
r
APPLICANT 7. Name RICHARD MARTIN i iO.Telephone 1 (503) 255 -9488
8. Company CAPITOL ELECTRIC CO.,XI3C 1 11. Date 12/03/99
1 1
9_ Signature J
_ 12/93/99 15:36 FAX 15032212077 LRS ARCHITECTS, INC. Z007
_12-03 -1999 10:26AM FROM CAPITOL ELECTRIC 2551966 P.7
•
Form 5b
Project: TIGARD CORP. BLDG. C Page: 1
12/03/99
INTERIOR LIGHTING POWER - Occupancy Method 1 1 i
Retail or1 (a) (b) 4 (c) , (d) (e) (f) (g)
Max Lighting
•
n , Floor Power Power
digs 1
dice Area Allow. Budget
Li (ft2) (W /ft2) (c -d) x e + f
Power r Group Area
(Group M)
If area is less than 0 0
• 2,000 ft2, enter 0 0 3.4
area in (c)
If area is between
2,000 and 6,000 ft2 2,000 2.5 6,800
enter area in (c)
If area over
6,000 ft2, enter 6,000 1.7 16,800
area in (c) 1 t
. ' ( }
r
1 1 1
Use (a) 1 (b) (c) I (d) (e) (f) (g)
Other 1 Max Lighting
Than Ceiling Floor (Power 1 Power
Group M Height Area {Allow. 1 Budget
Power Group
Occupancy Use (ft2) (W /ft2) (c -d) x e + f
1 _
(Group M) 1
B I OFFICE underlS 41,0701 1.2 49,284
' 1 ) o 1
I
1. Total Interior Lighting Power Budget (W). 1 49,284
2. Sum the page total(s) from Worksheet Sb 40,007
3. Total lineal feet of track lighting I o
~4_ Multiply line 3 by 50• 0
5. Total Interior Lighting Power (line 2 and 4) 40,007
•
6. Total Control Credit from Worksheet 5c 0
7. Total Adjusted Lighting Power (W) (line 6 - 5) 40,007
8. Does design meet the budget? Otherwise redesign Yes
•
, 121.03/99 15:36 FAX 15032212077 LRS ARCHITECTS, INC. a006
-12 -03 -1999 10:27AM FROM CAPITOL ELECTRIC 2551966 P_8 •
Project: TIGARD CORP. SLDG C
Page: 1 !
Worksheet 5a 12/03/99
LIGHTING SCHEDULE
(d) ( e) (f)
(a)� (b} Lamp Ballast Tab
Luminaire Sb
Lum. Fixture ' Power "x"
No.I Description No. Descript_
ID � Description ,
A 2X4 TROFFER
3 F32T8 1.0 ELECT 90
AEM 2X4 TR OFFER 3 1F32T8 1.0 ELECT 90 .
A B 2X4 TROFFER
3 F32T8 1.0 ELECT 90
C 1X4 WRAP
3 F32T8 1.0 ELECT 90
4
D STRIP
1 F32T8 1.0 ELECT 42
D2 STRIP
1 F32T8 110 ELECT 42
FEM 4' WALL 2 F32T8 1 -0 ELECT 71
G STRIP
2 F32T8 1.0 ELECT 71
H RECESSED
1 26W TRIPPLE 1.0 ELECT 37
J RECESSED
1 32W TRIPPLE 1.0 ELECT 46
JEM RECESSED
1 32W TRIPPLE 1.0 ELECT 46
Tt RECESSED
1 13W TWIN 1.0 ELECT 17
KEM RECESSED
1 13W TWIN 1.0 ELECT 17
L SURFACE HID
1 250W MH 1.0 MAGNETIC 240
Q !RECESSED
1 42W TRIPPLE 1.0 ELECT 60
QEM IRECESSED
1 42W TRIPPLE 1.0 ELECT 60
i
R RECESSED 1, 100W A19 0.0 100
1
1
1
. 12403/99 15:37 FAX 15032212077 LRS ARCHITECTS. INC. (j009
_12 -03 -1999 10 :27AM FROM CAPITOL ELECTRIC 2551966
P. 9
Worksheet 5b
Project! TIGARD CORP. BLDG. C Page: 1
12/03/99
INTERIOR LIGHTING POWER
(a) (b) (c) 1 (a) (e) Lighting
Room or Room or Plane
LuminairelQuantity oftLuminaire Power
,
Sheet No.
Designation ID Luminaires { Power (d) x (e)
E2 /E3 1ST /2ND FLOOR LIGHTING
A I 265 , 90 23,850
E2 /E3 1ST /2ND FLOOR LIGHTING
AEM 70 90 6,300
E2 /E3 1ST /2ND FLOOR LIGHTING 13
1 5 90 450
. C 1- 3 4 90 270
1 2 FLOOR LIGHTING 1ST/ 2ND E2 /E3 I 1
E2 /E3 1ST /2ND FLOOR LIGHTING
D ` 24 I 42 1,008
E2/E3 1ST /2ND FLOOR LIGHTING • D2 2 I 42 84
E2 /E3 1ST /2ND FLOOR LIGHTING FEM I y 8 71 568
E2 /E3 1ST /2ND FLOOR LIGHTING
G 3 ` 71 213
16 , 37 592
E2 /E3 1ST /2ND FLOOR LIGHTING H
E2 /E3 1ST /2ND FLOOR LIGHTING
J 34 I 46 1,564
E2 /E3 1ST /2ND FLOOR LYGRTING
JEM 13 46 598
,
E2 /E3 1ST /2ND FLOOR LIGHTING K 24 17 408
E2 /E3 1ST /2ND FLOOR LIGHTING KEM 6 17 102 -I E2 /E3 1ST /2ND FLOOR LIGHTING
L 4 240 960
E2 /E3 1ST /2ND FLOOR LIGHTING
Q 10 60 600
E2 /E3 1ST /2ND FLOOR LIGHTING
CAM 14 60 840
E2 /E3 I1ST /2ND FLOOR LIGHTING
R 16 100 1,600
t
1
f
40,00
1. Page Total. Sum the amounts in column (f) ,