Plans (711) GS0 ( ''-aozC _ ,
WALLS AND INTERIOR PARTITIONS, NONCOMBUSTIBLE
GA FILE NO. WP 1072 1 1 GENERIC I 1 HOUR 45 to 49 STC
GYPSUM WALLBOARD, STEEL STUDS FIRE SOUND
One layer 6 /e° type X gypsum wallboard or gypsum veneer base applied parallel or at right T • rT • ,
angles to each side of 3e /e' steel studs 24° o.c. with 1° Type S drywall screws 8° o.c. at 111 vertical oints and 12° o.c. at floor and ceilin g runners and intermediate studs. 1111W
.
Joints staggered 24° on each side and on opposite sides. Sound tested with 3 glass fiber
friction fit in stud space. (NLB)
Thickness: 4 °
IV . Limiting Height: Refer to Section IV
T Approx. Weight: 6 psf
• Fire Test: See WP 1200
(FM WP-45, 6- 19-68;
OSU T- 1770, 8-61;
ULC 79T484, 79T500,79T497,
8- 12-81, ULC Design W415)
Sound Test NRCC 816 -NV, 2 -3-81
GA FILE NO. WP 1073 I 1 PROPRIETARY • I 1 HOUR 45 to 49 STC 1
FIRE SOUND i;:
GLASS MAT GYPSUM BOARD, STEEL STUDS, +
GLASS FIBER INSULATION i 1
One layer 1 /2° proprietary type X glass mat water - resistant gypsum backing board applied i !YIYS ?i to each side of 2+/2' steel studs 16° o.c. with 1° Type S drywall screws 8' o.c. at
vertical joints and 12° o.c. at intermediate studs and wall perimeter. 3 glass fiber
insulation, 0.526 pcf, friction fit in stud space.
Joints staggered 16° on opposite sides and covered with 10 x 10 mesh glass tape and tile Thickn 31/2° . 1
adhesive. (NLB) Limiting Height: Refer to manufacturer
PROPRIETARY GYPSUM BOARD Approx. Weight: 5 psf
G-P Gypsum /2" Dens Shield® Fire Test CTC 1897 -1655, 1 -11 -88 ,
Sound Test See WP 1070
' (RAL TL69 -42, 10-17-68)
GA FILE NO. WP 1076 I I PROPRIETARY* 1 1 HOUR 45 to 49 STC I
FIRE SOUND
GYPSUM WALLBOARD, STEEL STUDS, j
GLASS FIBER INSULATION . I
One layer $ /e° proprietary type X gypsum wallboard or gypsum veneer base applied parallel ipiFitititi O I/,,,,,,/i , to each side of 2t /2° steel studs 24° o.c. with 1 Type S drywall screws 8° o.c. at wall le ' WH � I it
perimeter and 12° o.c. at vertical joints and with 1 Type S drywall screws 12° o.c. or . . .
continuous t /4° beads of adhesive at intermediate studs. 2 glass fiber insulation, 0.65 1'
pcf, friction fit in stud space. If
Joints staggered 24° on opposite sides. (NLB) Thickness: 3 .
PROPRIETARY GYPSUM BOARD Limiting Height: Refer to manufacturer , •
BPB Canada Inc. - e /e° ProRocTM' Type X Gypsum Panels Fire Te . Weight 6 psf
e /e° Tou hRock® Fir uard® Fire Test: ULC 78T55, 1-9-79,
G P Gypsum - g ULC Design W409
Sound Test: DRC 70 -2 -2, 1-6-70
I
GA FILE NO. WP 1061
1 I PROPRIETARY* 1 1
FIRE SOUND C
GYPSUM WALLBOARD, STEEL STUDS
One layer S/e° proprietary type X gypsum wallboard applied parallel to each side of 3 •
steel studs 24° o.c. with 1° Type S drywall screws 8° o.c. at vertical joints and 12° o.c. ifitti �, 1
at floor and ceiling runners and intermediate studs. Optional horizontal resilient channel ,� 24 ° o.c applied to studs with one t /2" Type S -12 pan head screw at each stud
Intersection. 1
Stagger joints 24° on each side and on opposite sides. Sound tested with 3" mineral fiber,
2.5 pcf, in stud space. (NLB) Thickness: 47/e
PROPRIETARY GYPSUM BOARD Limiting Height: Refer to Section IV
Approx. Weight: 5 psf I
G -P Gypsum - 6 /e" ToughRock® Fireguard® Fire Test: UL R1319, 94NK40598,
Lafarge North America Inc. 3/4° Firecheck® 11- 30 -94,
United States Gypsum Company - 5 /s° SHEETROCK® Brand UL Design U465
Abuse- Resistant Gypsum Panels Sound Test: USG - 960709, 7- 18 -96;
RAL -TL99 -103, 6- 28 -99;
RAL -TL99 -160, 9 -3 -99
GA-600 -2003 t Contact the manufacturer for more detailed information on proprietary products. 33