Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans (707)
CITY OF TIGARD, OREGON BUILDING DEVELOPMENT DIVISION 13125 SW HALL BLVD., TIGARD, OREGON 97223 lmuLTrlO RH unTY Architectural Revision 2 Description Applicatio #. BUP2006 -00 From Review dated: October 27, 2006 Date. . .06 Revision 2 From: BRIAN FREY Work: 503 236-6000 MYHRE GROUP ARCHITECTS APPLICANT 700 SW TAYLOR ST., SUITE 400 Home: 503 236 -7500 PORTLAND OR 97205 brianf@myhregroup.com To: PLANS Phone: 503.639.4171 EXAMINER VAL HENZEL E -mail: val a©rtigard- or.gov cc: Mark Ferris OWNER Dartmouth Square LLC Phone: 503.598.3440 7165 SW Fir Loop, suite 100 Tigard, Oregon 97223 Fax: 503.598.3450 PROJECT INFORMATION Street Address: 11935 SW 70 Avenue Description of Work: NEW 3-STORY OFFICE BUILDING WITH ABOVE GRADE PARKING. The following assumptions were made while reviewing this project: Occupancy group Construction Type Square Footage Stories Sprinklers Alarms Detection B II -B - 38,830 3 Yes Yes Yes PLAN REVIEW Based on the plan review comments submitted, the following items have been addressed and are outlined herein: Item # Location Clarification / Correction Provided on plans Structural 01 Structural Structural Review was submitted to Froelich Consulting Engineers. Myhre Group received a copy of structural review on 10/31/06. Architectural 02 G0.4 Details modified to clarify metal stud gauges, fastener information, thermal requirements and TYP. general construction of wall, floor and roof assemblies. 03 A1.1 Callouts provided for clarification of dedicated car /van pool parking. 04 5/A1.2 Provide note linking drawing to structural connection of materials. 05 A2.1 Provide additional dimensioning for clarification and additional wall section callout. Page 1 06 A2.2 Provide additional dimensioning for clarification and additional wall section callout. 07 A2.3 Provide additional dimensioning for clarification and additional wall section callout. 08 11/A5.2, Provide addition dimensioning to clarify construction requirements. Provide wall type 12/A5.2 callouts for exit stair construction. 09 A5.6 Modify wall construction to reflect design conditions and furring requirements. TYP. 10 1/A6.1, Add floor drains to bathrooms, janitor's closet and fire- sprinkler room. Note ADA 2/A6.1, dimensional compliance of door swing overlap. 3/A6.1 11 A7.1 Modify details to reflect roof design assembly. Provide reference callouts for floor TYP. assemblies. 12 6/A7.1 Provide entry soffit assembly information. 13 A7.2 Modify details to reference roof design assembly. Provide reference callouts for roof TYP. assemblies. 14 A7.5 Clarify detail callout information. TYP. 15 A8.1 Clarification of spandrel glass location. Provide detail callout Windows M, N and P. 16 A8.2 Modify details to clarify weep hole spacing. Provide additional details to clarify construction requirements of entries. 17 A10.2 Provide clarification of floor finish locations for Stair A03. - 18 A10.3 Provide clarification of floor finish locations for Stair A03. Page 2