Loading...
Plans (11) CITY OF 7 / " TIGARD, OREGON Wes' BUILDING DEVELOPMENT DIVISION 13125 SW HALL BLVD., TIGARD. OREGON 97223 TULTIMMRH caunTY Site Review #1 Checksheet Response Application #: SIT2006 -00008 From Review dated: November 7, 2006 Date: 11.16.06 From: BRIAN FREY Work: 503 236 -6000 MYHRE GROUP ARCHITECTS APPLICANT 700 SW TAYLOR ST., SUITE 400 Fax: 503 236 -7500 PORTLAND OR 97205 E -mail: brianfemvhregroup.com To: PLANS VAL HENZEL Phone: 503.639.4171 EXAMINER E -mail: val @tioard- or.qov cc: Mark Ferris Phone: 503.598.3440 OWNER Dartmouth Square, LLC Fax: 503.598.3450 7165 SW Fir Loop, suite 100 Tigard, Oregon 97223 E -mail: markf a(�.zimmler.com CIVIL Scott Emmons Phone: 503.238.2097 LANPACIFIC E -mail: jseelanoacific.com PROJECT INFORMATION Street Address: 11935 SW 70` Avenue Description of Work: NEW 3 -STORY OFFICE BUILDING WITH ABOVE GRADE PARKING. The following assumptions were made while reviewing this project: Occupancy group Construction Type Square Footage Stories Sprinklers Alarms Detection B II -B - 38,830 3 Yes Yes Yes PLAN REVIEW Based on the plan review comments submitted, the following items have been addressed and are outlined herein: Locatlo Code Item # n on Section Clarification / Correction Required plans Fire Review 01 OFC 508 The submitted hydrant work sheet shows four hydrants required, the site plan shows only three hydrants. Where is the fourth hydrant located? The existing fire hydrant located across the street and has been approved as the required fourth fire hydrant, see attached e-mail from John Dalby. dated 11.09.06 for approval of hydrant design and location. 02 Sheet C13 shows fire hydrant/ Sprinkler Vault / FDC located on private property check with TWD for location requirements on private property and provide copy of easement. An easement is to be a deferred submittal. Page 1 03 OFC 905 Provide approval from Fire Marshalls office on fire hydrant design and location. Please contact John Dalby, Deputy Fire Marshal for these requirements @ 503 - 356 -4723. See attached e-mail from John Dalby, dated 11.09.06 for approval of hydrant design and location. _ I 04 OFC 503 Provide approval on site slope and access road entrance stating this meets OFC 503. Contact John Dalby, Deputy Fire Marshal for these requirements @ 503 -356 -4723. See attached a -mall from John Dalby, dated 11.09.06 for approval of site slope and access road entrance. 05 NFPA 24 Underground Fire Fighting Water Supply: Provide thrust blocking details Section 4.1.3 including cut sheets and installation instructions for any mechanical joint 13:8 -1.1.1 c onnections. Provide supply pipe burial depth, piping ( 1 PP Y P�P P P�P� 9 sizes and materials, valve equipment cut sheets, vault details, equipment in vaults, details for hydrants and Fire Department Connection (FDC) location that are necessary for the installation of the fire service. All valves shall be listed for use in a fire service application. Working plans shall be drawn to an indicated scale on sheets of uniform size, with a plan of each floor, and shall include the following items that pertain to the design of the system: (1) The size and location of all water supplies (2) The size and location of standpipe risers, hose outlets, hand hose, monitor nozzles, and related equipment (3) The following items that pertain to private fire service mains: a. Size b. Length c. Location d. Weight e. Material f. Point of connection to city main g. Sizes, types, and locations of valves, valve indicators, regulators, meters, and valve pits h. Depth at which the top of the pipe is laid below grade (4) The following items that pertain to hydrants: a. Size and location, including size and number of outlets and whether outlets are to be equipped with independent gate valves. b. Whether hose houses and equipment are to be provided, and by whom c. Static and residual hydrants used in flow (5) Size, location, and piping arrangement of fire department connections Plan view and detail information for the above referenced information is found on sheets C10, C11, C13 and C18 of the site civil construction plans. 06 1103.1 Clarify the accessible route to the public way as required by section 1103.1 OSSC OSSC. The accessible route to the public way is from the access at Dartmouth Street. The building is served by an elevator providing full accessibility access to all floors. See attached e-mail from Brian Blaylock for approval. dated 7.28.06. Page 2 07 Section 1103 The accessible parking shown on sheet CO3 appears not to provide an & 1104. accessible route from the access aisle to the proposed side walk to (OSSC 106) structure. Provide site accessibility information as required per section 1103 & 1104. (OSSC 106) Site accessibility is provided per OSSC Sections 1103 and 1104 as indicated on sheets CO3 - Site Plan and C04 - Grading Plan. An at grade path of travel is provided from all accessible parking stalls to the 2"`' floor lobby building entrance and the number of stalls meet the requirements of 1104 Parking Facilities as indicated with 5 accessible stalls. one of which is van accessible. 08 1103.2.4.3 Accessible walkways and routes shall not exceed a running slope of 1 unit OSSC vertical in 20 units horizontal (5% slope). Cross slopes shall not exceed 1 unit vertical in 50 units horizontal (2% slope). Accessible routes do not exceed 5% running slope and 2% cross slope as indicated in sheet C04 — Grading Plan. 09 Accessible parking signs are required to be 84 inches to the bottom of the sign. Provide sign detail. Please see attached Rev 4 for revised Typical ADA parking Sign with mounting heights as indicated. Page 3 Page 1 of 2 Brian Frey From: Scott Emmens Use @lanpacific.comj Sent: Thursday, November 16, 2006 9:13 AM To: Brian Frey Subject: FW: Dartmouth Square Improvements Here is John Dalby's response he sent last week. He also cc'd Val and Kim at the City. Scott Emmens, PE LanPacific, Inc. 1001 SE Water Ave., Suite 360 Portland, Oregon 97214 Ph: (503) 238 -2097 Fx: (503) 238 -2447 www.Ianpacific.com From: Dalby, John K. [mailto:John.Dalby @tvfr.com] Sent: Thursday, November 09, 2006 4:09 PM To: jse @lanpacific.com Cc: val @tigard- or.gov; Kim Mcmiilan Subject: RE: Dartmouth Square Improvements The submitted drawings and calculations are approved insofar as fire apparatus access and firefighting water supplies are concerned. We trust this will clear the way for this project insofar as fire district regulations are concerned. John K. Dalby, Deputy Fire Marshal II Tualatin Valley Fire & Rescue, North Division 14480 SW Jenkins Road Beaverton, OR 97005 -1152 503 - 356 -4723 From: Scott Emmens [mailto:jse @Ianpacific.com] Sent: Wednesday, November 08, 2006 4:38 PM To: Dalby, John K. Subject: FW: Dartmouth Square Improvements Hi John, I got your voice mail earlier. Thanks for calling back. Below is the email I sent you back the first week of September. I understand your concern about the driveway grades coming off of 70'" Ave. Since my meeting with you, I updated the driveway grades in the driveway. The driveway and sidewalk at the entrance is sloped down and away from centerline at the same grade as the cross slope of the road (2.0 %). At back of walk, the driveway drops down on a vertical to a maximum of 15% and then flattens to 8 %. thanks Scott Emmens, PE LanPacific, Inc. 1001 SE Water Ave., Suite 360 Portland, Oregon 97214 11/16/2006 Page 2 of 2 Ph: (503) 238 -2097 Fx: (503) 238-2447 www.lanpacific.com From Scott Emmens [mailto:jse@Ianpacific.com] Sent Friday, September 08, 2006 10:08 AM To: 'john.dalby @tvfr.com' Subject Dartmouth Square Improvements John, 1 met with you a few weeks ago regarding the Dartmouth Square commercial development. The site is located on the northwest comer of Dartmouth St and SW 70"' Ave in Tigard. I've updated the plans since we last spoke. I've attached three construction drawing sheets and the fire flow calc sheet for you to review. Sheet C10 — Dartmouth public Improvements Sheet C11 — 70s' Ave Public Improvements Sheet C13 — Onsite water and sanitary sewer improvements I would like to follow up with you by this aftemoon if you're available. Thanks, Scott Emmens, PE LanPacific, Inc. 1001 SE Water Ave., Suite 360 Portland, Oregon 97214 Ph: (503) 238 -2097 Fx: (503) 238 -2447 www.lanpacific.com 11/16/2006 Brian Frey From: Doug Strickler Idws@lanpacific.com] Sent: Wednesday, June 28, 2006 9:56 AM To: Scott Emmens; Brian Frey; 'Mark Ferris' Cc: Erik Esparza; Brian Keefer Subject: FW: Dartmouth Square conditions of approval Hi Group - Here is the response I got regarding the Dartmouth Square accessibility issue. T guess "On the nose!" is as clear an indication as we could ask for. Regards, Doug S. Doug Strickler, LEED Senior Planner LanPacific, Inc. 1001 SE Water Ave., Suite #360 Portland, OR 97214 Phone: 503.238.2097 Fax: 503.238.2447 Original Message From: Brian Blalock Imailto:brianb @tigard- or.govI Sent: Wednesday, June 28, 2.006 5:28 AM To: dws@lanpacific.com Subject: Re: Dartmouth Square conditions of approval On the nose! »> "Doug Strickler" <dws @lanpacific.com> 06/26 4:37 PM >» Brian - I am the planner who wrote the application for the Dartmouth Square application, and I was talking with Scott Emmens today about the Conditions of Approval for that project, particularly #1 which concerned the project having an accessible route to both SW Dartmouth Street and SW 70th Avenue. It is my understanding, from discussions with Scott, that your concerns were based on your review of a set of plans that apparently showed stairs at the Dartmouth Street entrance and no elevator connecting all three floors. It is further my understanding that if plans are submitted that do not have stairs at the Dartmouth Street entrance and that clearly show the presence of an elevator providing access to all three floors, that your concerns regarding accessibility would he adequately addressed. Could you please advise me as to the whether my understanding of the situation is correct and whether it would be helpful to sit down with you and a set of current plans to verify the adequacy of the access that we are proposing for the building? I know it would be helpful to us to have a high degree of confidence that our plans address your concerns before developing them further. I look forward to hearing from you regarding this matter. Regards, 1 Doug Strickler, LEED Senior Planner LanPacific, Inc. 1001 SE Water Ave., Suite #360 Portland, OR 97214 Phone: 503.238.2097 Fax: 503.238.2447 2 Site Address: I R 3S Sw 70 r ' i✓L 14A/t t 0(2- ' t 7 Z23 - - -) Letter of Transmittal Building Division C u f Ta DATE RECEIVED: T0: \ 1c, Ne./4ZC.L. DEPT: BUILDING DIVISION FROM: _get1l,J ri-L-Y COMPANY: i'k'rt 620, A2cr1 PHONE NO.: (5 Z36 - '000 By; RE S IT 6.- 00008 11935 Sw 70 Av6. (Case number, site address, etc.) OAfLTfrtDv H ovn-/LE (Project name or subdivision name and lot number) ATTACHED ARE THE FOLLOWING ITEMS: I Copies: I Description: 1 Copies: Description: Additional set(s) of plans. 9 ,. Revisions: 'L Cross section(s) and details. Wall bracing and /or lateral analysis. Floor /roof framing. Basement and retaining walls. Beam calculations. Engineer's calculations. 1 Other(explain): SsrE i evic.' gerPo e REIVIA.RKS: - Sire ,,cwe.w # 1 cmcc r2c5✓D,J5 tr CaJFt2/'1A1 J f r1A.L • CoPiES Ders%. r ?��t'rG!9 T;a titt,401c P flgly 4, GI`I For Office Use Only: 1 Routed to Permit Technician: Date: 1 Initials: Fees Due: $ _ Date: j Initials: Re rint Permit ( er Plans Examiner : { Yes: _ _ 1 No: — 1 Notified Applicant: Date: 1 Initials: i:(3uildingTornacttcrTrmumitml dra 14'04 • 1' ALUMINUM SIGN PLATE 3/8' 3/8. YVHITE BACKGROOND. 1 NIGH BLUE LETTERS MO,..,, AND BORDER, BAKED ENAMEL. aM OlOOLIO NW Olt MONO MEM WOO woe awns. to 1 -31' 1.5' GALVAN]ZED e , STEEL POST VAN HANDICAP SYMBOL WHITE SIGN �9LE WITH BWE BACKGROUND sGN 04' MOUNT HEIGHT Q 2' -0' MW t TYPICAL HANDICAP PARKING SIGN NOT TO SCALE