Correspondence (2) f c 21 03 0
July 21, 2003
Mark Stolle
Joseph Hughes Construction
7035 SW Hampton Street
Tigard, OR 97223
RE: ENYEART OFFICE BUILDING
Project Information
Site Permit: SIT2003 -00019 Construction Type: VN
Tenant Name: Speculative Occupancy Type: B
Address: 12665 SW 69 Occupant Load: NA
Area: 6,357 Sq Ft Stories: 2
The plan review was performed under the State of Oregon Structural Specialty Code (OSSC)
1998 edition; and the Tualatin Valley Fire & Rescue Ordinance 99 -01 (TVFR99 -01) 1999
edition. The following information is required prior to the issuance of a Site Permit:
EXCAVATION
1. Complete the enclosed permit application clarifying the Excavation, Grading and Fill
volumes.
2. Complete the enclosed permit application clarifying the new impervious area.
Impervious is defined as building roof areas, sidewalks and paving. The number
should be what is new impervious as related to what was existing.
RETAINING WALLS
3. A retaining wall is shown at the North, West & South side of the project. The wall is
noted as being modular concrete block and 4 feet tall. The wall itself does not require
a permit; however, the manufacturer may require drainage for the retaining walls.
Indicate piping slope, size, material and backwater valves including the connection to
an approved point of discharge.
FIRE REVIEW
4. Complete the enclosed "TVF &R FIRE FLOW and HYDRANT WORKSHEET ". The
allowable area permitted and the number of hydrants required will be based on the
worksheet.
ACCESSIBILITY
5. The accessible parking shown on sheet 3 of 9 does not provide an accessible route
from the access aisle to the proposed structure. Indicate the method of identifying the
accessible route on the plans.1103.1 OSSC
6. The accessible ramp indicated on sheet 3 of 9 at the East end of the site scales at 4
feet in width. The ramp has a change in direction that has the same width as the ramp.
Revise the drawings to indicate the code required change of direction landing of 5
feet x 5 feet. Section 1109.7.5 OSSC
7. The curb ramp detail on sheet 8 of 9 does not indicate a level landing at the top that is
5 feet in the direction of travel as required by section 1109.7.5 OSSC. Revise the
detail.
8. Accessible parking sign shall be provided at the accessible parking space. The sign is
required to be 84 inches to the bottom of the sign. Provide a detail.
FYI Accessible walkways and routes shall not exceed a running slope of 1 unit vertical in 20
units horizontal (5% slope). Cross slopes shall not exceed 1 unit vertical in 50 units
horizontal (2% slope). 1103.2.4.3 OSSC
Please provide an item by item response.
When submitting revised drawings or additional information, please attach a copy of the
enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of
Tigard in tracking and processing the documents.
Respectfully,
Brian Blalock,
Senior Plans Examiner