Permit IN CITY OF TIGARD MASTER PERMIT II COMMUNITY DEVELOPMENT Permit #: MST201000143 T I G Ail. D 13125 SW Hall Blvd., Tigard OR 97223 503.639.4171 Date Issued: 09/28/2010 Parcel: 2S111 BA10100 Jurisdiction: Tigard Site address: 9441 SW BROOKLYN LN Subdivision: SHANNON MEADOWS Lot: 6 Project: Doebler Project Description: Second story addition. BUILDING Floor Areas Required Setbacks Required Stories: 2 Bedrooms: 1 First: 0 sf Basement: 0 sf Left: 0 Parking Spaces: 0 Height: 21 Bathrooms: 0 Second: 209 sf Garage: 0 sf Front 0 Smoke Dwelling Units: 1 Third: 0 sf Right 0 Detectors: Yes Total: sf Value: $28,000.00 Rear: 0 PLUMBING Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Catch Basins: 0 Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Other Fixtures: 0 Tubs /Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Drains: 0 Bckflw Prevntr: 0 MECHANICAL Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0 Heat Pump: N Hoods: 0 Other Units: 1 Fum <100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0 Fum > =100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc /Feeders Branch Circuits 1000 sf or less: 0 0 -200 amp: 0 0 -200 amp: 0 W/ Svc or Fdr: 0 Ea add, 500 sf: 0 20 1 -400 amp: 0 201 -400 amp: 0 1st W/O Svc/Fdr: Limited Energy: 401 -600 amp: 0 401 -600 amp: 0 Ea add, Br Cir: 601 -1000 amp: 0 601 +amp- 1000v: 0 1000 +amp /volt: 0 ELECTRICAL - RESTRICTED ENERGY SF Residential Audio & Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Other: N Other Description: Ecompasing: N BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: Owner: Contractor: Required Items and Reports (Conditions) DOEBLER, GABRIEL P & KENDAL RICKERT CONSTRUCTION CO. INC. M 2004 VALERI DR. 9441 SW BROOKLYN LN Newberg, OR 97132 TIGARD, OR 97224 PHONE: PHONE: 503 - 260 -3806 FAX: 503 - 537 -1941 Total Fees: $1,245.18 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules areNset t h in OAR 952- 001 -0010 through OAR 9 2- 001 -0100. You may obtain a copy of the rules or direct questions to OUNC by calling 503.2 • • • • "= or 1.800.3 . • 4. Issued By: ___ P e r m Signature: _...a.....ed Building Permit Application e4i) Received , Residential FOR orrlcl use ONLY of Tigard l�� Date /B : I � 0 / Permit No.: .`• U /K lig Tigard, OR 223 � a 13125 SW Hall Blvd., Ti g ` Plan Review � � � Phone: 503.639.4171 Fax: 503.598.19$ O � ,,Cjl � C 1 Date/By: D ate Read � L 10 Other Permit: T I G ,� R D Inspection Line: 503.639 : luris: la See Page 2 for Internet: www.tigard C \ ((�, G� Notified/Method: r , /0 fr. y Supplemental Information `� VA./ ,a s' TYPE OF WORK REQUIRED DATA: 1- AND 2- FAMILY DWELLING ❑ New construction ❑ Demolition Permit fees* are based on the value of the work performed. Indicate the value (rounded to the nearest dollar) of all ® Addition/alteration/replacement ❑ Other: equipment, materials, labor, overhead, and the profit for the CATEGORY OF CONSTRUCTION work indicated on this application. Valuation: $ ® 1- and 2- family dwelling ❑ Commercial /industrial 1 dClO ❑ Accessory building ❑ Multi- family Number of bedrooms: 3 ❑ Master builder ❑ Other: Number of bathrooms: 2.5 JOB SITE INFORMATION AND LOCATION Total number of floors: 2 Job site address: 9441 Brooklyn Lane New dwelling area: 209 square feet City /State /ZIP: Tigard, Or 97224 Garage /carport area: square feet Suite/bldg. /apt. no.: Project name: Doebler Residence Covered porch area: square feet Cross street/directions to job site: SW 97` Ave Deck area: square feet Other structure area: square feet REQUIRED DATA: COMMERCIAL -USE CHECKLIST Subdivision: I Lot no.: Permit fees* are based on the value of the work performed. Tax map /parcel no.: Indicate the value (rounded to the nearest dollar) of all equipment, materials, labor, overhead, and the profit for the DESCRIPTION OF WORK work indicated on this application. The addition of a 2 story bonus room above an existing garage Valuation: $ Existing building area: square feet New building area: square feet ® PROPERTY OWNER ❑ TENANT Number of stories: Name: Gabe & Kendall Doebler Type of construction: Address: 9441 Brooklyn Ln. Occupancy groups: City /State /ZIP: Tigard, Or, 97224 Existing: Phone: (971)227 -9519 Fax:( ) New: ® APPLICANT ❑ CONTACT PERSON NOTICE Business name: Rickert Construction Co. Inc. All contractors and subcontractors are required to be Contact name: Randy Rickert licensed with the Oregon Construction Contractors Board under ORS 701 and may be required to be licensed in the Address: 2004 Valeri Drive jurisdiction in which work is being performed. If the City /State /ZIP: Newberg, Or 97132 applicant is exempt from licensing, the following reasons apply: Phone: (503) 260 -3806 I Fax: : (503) 537-1941 E -mail: Rickertinc @aol.com CONTRACTOR Business name: Rickert Construction Co. Inc BUILDING PERMIT FEES* Address: 2004 Valeri Drive (Please refer to fee schedule) Structural plan review fee (or deposit): City /State /ZIP: Newberg, Or 97132 Phone: (503 -) 260 -3806 Fax: (503) 537 -1941 FLS plan review fee (if applicable): CCB lic.: 128968 / f / /�— Total fees due upon application: 4 3 ( c c--(4,,, /� Amount received: Authorized signature: / V/ This permit application expires if a permit is not obtained w ^ within 180 days after it has been accepted as complete. O Print name: M W .f( RI tx T Date: 8/16/2010 * Fee methodology set by Tri- County Building Industry Service Board. 1: \Building \Permits \BUP -RES PermitApp.doc 10/01/09 440- 4613T(11/02/COM /WEB) • . Electrical Permit A Iscati ? ki - • •14)1:0171 v , - • • • '' , City of Tigard .. -0P ( 1/4C; *" ' 4111111111111.. :-..-.`1-. p....it No.: IN " • 13125 SW Hall Blvd., Tig cm Lid ard, OR 97223 - . ' .. Review - P110110: 503.639.4171 Fax: 503.1080 '''' ,,,ae,wg Depay Other Permit: Inspection Line: 503.639.4175 %,.; t r:. r■ Data Rmdy/14-. Ma. I El See Page 3 for • • ,- • , -. Internet www.tigard-orgov W\1\1%11 Notified/Method: I Supplants:hid bifereastios TYPOAVOltk' . • • • ' • . . El New construction - 13Addition/alterationinsplacernent ' Please check all that apply hailanit I sots of plans wAtems shacked below): 0 Service or feeder am amps or rano CI DMIslin8 ma. three amiss 0 Demolition 0 Other. siemens° mailable huh ammo 0 Marinas IDA boatyards. • - . CATEGORE OF CONSTRUCTION • awes& 10,000 'asps m 150 wits or 0 Floating boildinp. ...... : Ims to gmand, or mooch 14,000 CI Commercial-use arrienhural lsVikl and 2-iatnily dwelling 0 Commercialfuutusnial 0 Accessory building amps for all other installations. buildings. 0 Multi-family 0 Master builder 0 Other: Elgire pas. 0 Installation of 75 KVA or 0 Emergency system. larger mipmately derived eystem. . .. , J. JOB SITE INFORMATION AND L'OlATIO?". . ' • CI Addition of new motor load of 0 - A - ,."Er, - I -2", - 1...r. fl Job no.: grCgon Job Site addreSS: r 4 T, g.....Fia.61k - -Vd : .P.' l OSi100HP °more x or mars residential mita, 0 Recreational vehicle mks. City/Suue/ZIP: 72 '7•12? .5! '3' 0 Hatddi-eara facilities. CI Supply voltage for Tama than / 15.-!.., 0 Ilazadous loalican. 600 volts nominal. Suite/bldg./apt. no.: Project name:_51 ()Service or Dales 600 memos more. - - • - FEE SCHEDULE Cross greet/directions to job site: Demiption 1 oty, J ma I Tool - Fr'. New residential aim*. or multi-thmily dwelling unit Includes attached garage. Subdivision: Lot no.: 1,000 m. ft. or less 168.54 4 Si. aderl 503 sq. R. or portion 33.92 I Tax map/parcel no.: Limited energy, residential . 75D0 2 DISCRIPPON,OF WORK (with above sq. tt.) • !imam! energy, malti-family 75.00 2 Le `57 Ofq ., A i)i>---.7-v!),t1 residential (with above sq. 6.) Services or feeders installation. alteration, andfor relocation 200 amps or las 100.70 2 0 PROPERTY OWNER • • . . - 0 - ru mar . 201 anon to 400 amps 133.56 2 401 amps to 600 amps 200.34 2 Name: 601 amps to I.000 amps 301.04 2 Addresx • Over 1,000 amps or volts 552.26 2 — ........ Temporary invites w feeden lasaIladon, alteration. and/or City/State/ZIP: relocattoo Phone: ( ) Fax: ( ) 200 1111918 00 less 5936 1 201 arnps to 400 amps 12508 ' 2 Owner installation: This installation is being made on plop iy that I own which is not 4V1 amps to 599 amps 169.54 2 intended for sale, lease, rent, or =Mange, according to ORS 447, 449. 670, and 701. Brand circuits - new. alteration, or extension, per panel Owner signature: Date: A. Fee for blanch circuib with above sari.= or feeder fee 0 APP / 7.42 7 ,q 7 21 . ' LICANT . I .0 CONTACT PEILSO N each branch circuit . B. Fee for brand circuits withort Business name: service o r feeder fee, fast . , Contact name: branch Micant / 56.18 2 . 56 . 1E5 *Each add'I branch circuit 7.42 2 Address: . Misedlaneous (service or feeder not included) • Each manufhaural or modular City/State/ZIP: • ,.. availing, service and/or feeder 67.84 2 Phone: ( ) 1 Fax: : ( ) _ Reconnect only 67.84 2 Pump or inigition circle 67.84 2 E Sign or outline lighting 67.84 2 . . . CONTRACTOR . . . Signal circuihs) or limitedenergy panel, alteration, ot extension. , Page 2 2 Businim name: VittiV .. c ... 6 E T1 Loeb addidonal Inspection over allowalde In any of the abov Address: 31 t Z,...Z...5 ' Additional inspection (I hr min) 6625/ hr Investigation (1 hr min) 6625/ hr Cit f P.-__ T7/3 - / / industrial plant (1 hr min) 74.1W hr 1 9173m (0) 437 40C2 G. i Fa ( - .... is• ( inspections for which no foe is 90.00/ hr 1 I spaificall9 listed (Yr la min) I CB Lic.: oi. Aii Electrical Lic.: ....., ._ gel Suprv. Lic.: :,. • ELECTRICAL PERMIT. FEES • ...0 _ Suprv. Electrician signature, required: 4 ,0: „„,,, pi...J.. OS% of permit fa* 111111111Wirlei P State madame (12% of permit fee): • rint name: !full- , Date — . All : 7 TOTAL PERMIT FEE: WilIFAM Authorized signaturm : ... - .....41111111M This pen& appkatioo apira if a permit b not obtained Mehl .41111,0".• Date: day. rdber it Ma ban accepted as complete. Print name: • Number of inspections allowed pa pennit. • INA11/6260Parmit40LC-Pensi8A994eo 0700)15 440.4615T(11A)SCOUNE13 :•' .• ' ... .. .. ....... ............. .. . . .. ..... . ' Mechanical Permit Application FoR OFFICE 1161: ONLY City of Tigard � Received Date/By: Review Permit No.: a 13125 SW Hall Blvd., Tigard, OR 97223 lig C Phone: 503.639.4171 Fax: 503. . . Date/By: Other Permit: T I G A Ii u Inspection Line: 503.639 , Date Ready/By: Juris: 65 See Page 2 for Internet: www.tigard - or.gov `� ` q a Notified/Method: Supplemental Information T YPE OF W RK 0 ��\ �S, COMMERCIAL, FEE* SCHEDULE — USE CHECKLIST New construction G� Mechanical permit fees* are based on the value of the work 12 ®Addition /altera(I /��nt performed. Indicate the value (rounded to the nearest dollar) of all . ❑ Demolition ❑ Other: 9 ta h mechanical materials, equipment, labor, overhead, and profit. . CATEGORY OF CONSTRUCTION • Value: $ RESIDENTIAL EQUIPMENT / SYSTEMS FEES* ® 1- and 2- family dwelling ❑ Commercial/industrial ❑ Accessory building For special information use checklist. ❑ Multi- family ❑ Master builder ❑ Other: Description 1 Qty. 1 Ea. 1 Total JOB SITE INFORMATION AND 'LOCATION Heating/cooling Job site address: 9441 SW Brooklyn Lane Air conditioning (requires site plan showing placement) 46.75 City /State /ZIP: Tigard, OR 97224 Furnace 100,000 BTU (ducts/vents) 46.75 Furnace 100,000+ BTU (ducts/vents) 54.91 Suite/bldg. /apt. no.: Project name: Doebler Residence Heat pump 61.06 Cross street/directions to job site: Duct work 2 23.32 Hydronic hot water system 23.32 Residential boiler (radiator or hydronic) 23.32 Unit heaters (fuel -type, not electric), in -wall, in -duct, suspended, etc. 46.75 Subdivision: Lot no.: Flue/vent for any of above 23.32 Other: _ 23.32 Tax map /parcel no.: Other fuel appliances DESCRIPTION OF WORK Water heater 23.32 Gas fireplace 33.39 Addition of bonus room above existing garage Flue vent for water heater or gas add two new heat ducts to existing system fireplace 23.32 Log lighter (gas) 23.32 Relocate gas line Wood/pellet stove 33.39 Wood fireplace /insert 23.32 ® PROPERTY, OWNER I . ❑ TENANT Chimney/liner/flue/vent Other: 23.32 Other: 23.32 Name: Gabe & Kendal Doebler Environmental exhaust and ventilation Address: 9441 SW Brooklyn Lane Range hood /other kitchen equipment 33.39 City /State /ZIP: Tigard, Or 97224 Clothes dryer exhaust 33.39 Single -duct exhaust (bathrooms, Phone: (971)227 -9519 Fax: ( ) toilet compartments, utility rooms) 23.32 ® APPLICANT ® CONTACT PERSON - _ Attic /crawlspace fans 23.32 Other: 23.32 Business name: Rickert Construction Co. Inc. Fuel Piping Contact name: Randy $14.15 for first four; $4.03 for each additional Address: 2004 Valeri Drive Furnace, etc. , Gas heat pump City /State /ZIP: Newberg, OR 97132 Wall /suspended/unit heater Phone: (503) 260 -3806 Fax: : (503) 537 -1941 Water heater Fireplace E -mail: Rickertinc @aol.com Range CONTRACTOR Barbecue Business name: Rickert Construction Co. Inc Clothes dryer (gas) Other: I Address: same as above MECHANICAL PERMITFEES* ..: '. City /State /ZIP: Subtotal Minimum permit fee ($90.00) Phone: ( ) Fax: ( ) Plan review (25% of permit fee) CCB lic.: 128968 State surcharge (12% of permit fee) TOTAL PERMIT FEE Authorized si ature: This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete Print name/ ,/ 1 Date: 9 / Z // p • Fee methodology set by Tri- County Building Industry Service Board I: \Building\Permits\MEC- PermitApp.doc 10/01/09 440- 4617T(11 /02/COM/WEB) 06,o - v October 6, 2010 1`4 Rickert Construction Company Attn: Randy Rickert 2004 Valeri Dr. Newberg, OR 97132 Subject: 9441 SW Brooklyn Ln, Tigard, OR Beam and Loading Clarification UTF Job Number: 10 -066 Dear Mr. Rickert: This letter is the clarify and modify the previously submitted plans in reference to the above listed site, and existing conditions as determined during construction and tear off where the existing beam in question was visible. Per our phone conversation, it was understood that the existing beam between the two car garage and the single car garage is a 6 3 /4" x 21" glulam beam. Per this offices previous assumptions and calculations, we assumed a 5 1/8" x 15" glulam beam. Per this pervious assumption which is now determined to be incorrect, we specified a new post and footing to support the mid -span of this existing beam. This is shown on the previously submitted and approved plans on 2/S4, and the footing as shown in the garage on 1/S4. After further calculations (attached), and your determination of the true size of the beam as a 6 3 /4" x 21" glulam, this office has determined that the center post and footing is no longer required to support the existing beam with the increased loading. If you have any questions, please do not hesitate to contact this office. Respectfully, , �t `� ` $9 PROF UTF C nsulting �S�` G 1 N £ / Geoffrey D. Wright, PE w sass Principal r GON C e G ' O 9 i .r 0 / \C> ' S 6 4(0; ow1RES: s /so/ ti L_ Ls r UTF Consulting (P) 503 -522 -2849 (F) 503- 848 -4695 gtoffcjulfconsullingcom 17740 SW Florence St., Beaverton, OR 97007 /9-vi 6 ao-merr Peez- s 0' I ( 61 • 4 ./ :4` 6e, P- -Cy : 5e?3-0441r- b ,L10,0 , 4, 7.t' F 964 om--.tiok„t/ 04, 0,101 r Ar5 2 sAwvi F) 6S p f L2c 4,1 4e 27 frr - r -zof 4 5ci 3 1 1 13 .-- 14 1 OREGON p= U ( ( ( 4( .; Fc (Es") texPIRES:_6/3.9/ (72- ( o k 1AP PROJECT: RESIDENTIAL REMODEUADDITION JOB ADDRESS: 9441 SW BROOKLYN LN., TIGARD, OR PROJECT #: 10-066 UTF CONSULTING CLIENT: RICKERT CONSTRUCTION 17740 SW FLORENCE ST. BEAVERTON, OR 97007 DATE: 08/01/10 PAGE: C.Jit,C t ( PHONE: 503-522-2849 FAX: 503-848-4695 www.uticonsulting.com •