Loading...
Correspondence OOO 2 6' - June 2, 1999 CITY OF TIG/11) Carlson Testing Inc. OREGON PO Box 23814 Tigard, Oregon 97223 PERMIT NO: BUP # 99 -00195 / Site Permit # 99 -00020 OWNER: Porter PROJECT ADDRESS: 125 SW 69 PROJECT DESCRIPTION: Commercial TYPES OF SPECIAL INSPECTION: As per Program attached The owner has notified us that he /she will retain your services to perform Special Inspections in accordance with the provisions of the State Building Code, permit documents and special inspection requirements. The owner or the owner's agent must also confirm with you that they have authorized you to do the special inspection work. } As the regulatory agency, the City requires that you do the following: 1. Submit copies of all inspection reports promptly to the building division, Architect, engineer, and the contractor. 2. Maintain one copy of each field report at the job site. 3. Submit a final report at the completion of each category of work that you Inspect. (See UBC Appendix Chapter 13 for soils special inspection final • report requirements.) If you fail to comply with the above requirements, there may be cause for the City to revoke your authority as special inspector for this job. Should you have any questions, please call me at (503) 639 -4171 X 392. Sincerel R ert D. Poskin, C.B.O. Seni Plans Examiner 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772 • (") CITY OF TIGARD A Program for Inspection Services and/or Material Testing Date: (912.4V4- ,1913 ,/ • City of Tigard: Plan Ck. No. s _�.10 Bup No. 141. DO lt5 Sit No. 94 _ OCO 2 Project Title: 4„1 Err iFincrce Address i1.Sc4 ,tie toe 1tao Architect of Record .art. Q.S�•�rea 41A Ph. &to - 2r +2 d ddress: Structural Engineer of Record: S.4,..‘ Ph. 6 A-- •b'48 address: t;.o v,Ja4.444• -. 1.1wacoa z Geo- Technical Engineer of Record: Ph. address: Provide the following information for the testing agency chosen to provide inspection services and/or testing. Testing Agency: Cy. — EScA" Ph. Fax. address Geo- Technical Agency: idsg'� G r 4g Ph Fax. address The owner certifies that the above noted Agency has been employed to conduct the speci : i nspections or ob ations required herein. • � , 6-63 1191 /(o s/zv/y y Sithnaurc o(Owne r Pone N Date tsc A - . f'o,e 2 R � b � eu w-711/ &v v ftt-n-1 r ce_L Prim n ame Company name The following is a list of special inspection and/or services required by the 1996 Oregon Structural Specialty Code and Tigard's Municipal Code 14.06.010 through 14.06.040. The special inspections and/or testing services required for this project to be provided by the Testing Agency. Structural Engineer or Geo- Technical Engineer of Record are as follows: • Special Inspectors for the Testing Agency shall be qualified, to the satisfaction of the Building Official, for inspections of the particular type of construction or operation. • Special inspectors shall observe the work assigned herein for conformance with the approved plans and specifications and_ submit copies of all inspection reports and. a final signed report in accordance with OSSC. Section 1701.3 to the building official. • i �. . . • • Structural Inspections Services and Material Testing I Category Description of Services Required ' Provide By Yes /No 1. Concrete. OSSC. Section 1701.5.1 and Section 1903, 1904 and 1905 a. Review concrete mix designs b Inspect the placing of reinforced concrete. C Observe the taking of test specimens. d. 2. Bolts Installed in concrete. OSSC, Section 1701.5.2 a. Prior to and during the placement of concrete around bolts when stresses permitted by section 1925 are utilized. b. 3. Special Moment Frame. OSSC, Section 1701.5.3 and section 192I.9 a. Provide continuous inspection oldie placement of reinforcing steel and concrete. and submit a certificate indicating compliance. b- • 4. Reinforcing Steel and Pre - Stressing Steel Tendons. OSSC, Section 1701.5A a. Inspection of reinforcing steel and pre stressing tendons before stressing and grouting of tendons in pre stressed concrete b. Observe and record results of all tendon stressing in pre stressed concrete. C. Observe grouting of all tendons in pre stressed concrete d. 5. Structural Welding. OSSC. Section 1701.5.5 and Section 1703 a Observe the welding of any member or connection designed to resist loads and forces required by the OSSC. b. Visually inspect floor and roof deck welding. c Visually inspect welded studs when used for structural diaphragm or composite systems. (shear walls) d. Visually inspect welding of stairs and railing systems. • e. • Check certification of welders doing work on site. Visually inspect the welding of studs and joist. (part of a.) Observe the welding of special moment - resisting steel frames, and g' conduct non -destructive testing required by OSSC, section 1703. h. Observe the welding of reinforcing steel. 1. Category Description of Services Required Provide By Yes /No • cr - .. _ r ' ( 6. High Strength Bolting. OSSC, Section 17013.6 The installation of A325 and A490 bolts shall be in accordance with Chapter 22. Division IV a. Verify bolt types, diameter and installation Periodic inspection shall be in accordance with OSSC, Section 1701.6 b ' Ecos.se 4.1.es /46cwn9us c. • 7. Structural Masonry. OSSC, Section 1701.5.7. and 2105 Other than fully grouted upon -end hollow -unit masonry. a. Visually verify placement of masonry units, reinforcing steel, inspection of grout spaces and taking any required prisim or tcst specimens, and be present during all grouting operations. Farley grouted open -end hollow -unit masonry . b. Visually verify the start of laying units, placement of reinforcing steel,. taking prisms or test specimens, inspect grout spaces and be present . during all !;routing operations. C. Verify that grout and mortar materials and proportions are in accordance with OSSC, Table 21 -A for Mortar and 21 -B for grout. d. C.tnu WAu. -ra cifeyhe.Arpfsre C. TitrRik bs r+s g-imp Q Gnu lice, tsrvahecrrrAft 8. Spray - applied fireproofing. OSSC. Section 1701.5.10 a. Visually verify the substrate condition, thickness determination and confirm density report are all in accordance with UBC, Standard 7-6 b. 9. Piling, Drilled Piers and Caissons. OSSC, Section 1701.5.11 • a. Present during driving of piles and subsequent testing, b. Inspect the construction ofcast -in -place drilled piles or caissons. C. Observe placing of reinforced concrete. • d. Observe placement of reinforcement steel e. 10. Sbotcrete. OSSC, Section 1701.5.12 a. Observe taking of test specimens b Observe the placement of all shotcrete used for structural members. Submit a statement of compliance with plans and specifications. C. Visual examination ofcompleted shotcrete work. Submit a report of the three test specimens required. d. SOILS Inspection Services and Materials Testing Special Grading, excavation and filling • Qn - ,.