Correspondence • LI 5 b - -, O
yv
116 116'
/11° /Oirrmdll „e:ril::�� 1
June 24, 1998 CITY OF 711
Jerry Robinson AIA 0 OREG
12000 SW Viewcrest
Tigard, OR 97224
RE: Bennett Porter Building Plan Review
12555 SW 69th •
PC #: 5-47c • BUP#: 98 -0204
PC #: 5-48c SIT #: 98 -0016
Submittal documents for the above referenced project have been reviewed for
conformance with the applicable 1996 Oregon Specialty Codes and other applicable
codes and standards. The following comments are noted:
n y ^.; , '/ _ � i/. 4 y:E: , //� // :: %, n.,{ / /-i„ j am, :SRC Xi % ; %i `
/„ �: % : �%� , %, � 4+`.x r '' / +' �
' // ;y7.'✓ {rsa.�,.,f .'i ' /;;: r.rfs¢.fir , r ,.� „'.f, / ri.. / !.V%.rL:;; � % `. ii ,:�� //. / Y, r...l.. / /iu�!f/��o '`�,/ �; i'?;'f/ ...;
1. Provide a liquefaction potential and soil strength loss report (OSSC, Section
1804.1.1 and 1804.5).
. COMMERCIAL BUILDINGS - MINIMUM NUMBER OF FIRE HYDRANTS: The
minimum number of fire hydrants for a building shall be based on the required
fire flow prior to giving any credits for fire protection systems. There shall not be
less than one (1) fire hydrant for the first 2,000 gallons per minute (GPM)
a,
required fire flow and one (1) additional fire hydrant for each 1,000 GPM or
portion thereof over 2,000 GPM. Fire hydrants shall be evenly spaced around
the building and their locations shall be approved by the building official. (UFC
Sec. 903.4.2.1)
W
3: COMMERCIAL BUILDINGS - FIRE HYDRANTS: No portion of the exterior of a
commercial building shall be located more than 250 feet from a fire hydrant when
measured in an approved manner around the outside of the building and along
an approved fire apparatus access roadway. (UFC Sec. 903.4.2.1)
GP COMMERCIAL BUILDINGS - REQUIRED FIRE FLOW: The required fire flow
for the building shall be 1500 gallons per minute (GPM) at 20 psi. Hydrants shall
y be flow tested in accordance with NFPA 291. Results shall be submitted to the
a le City of Tigard, Attn: Plans Examiner, 13125 SW Hall Blvd., Tigard, OR 97223,
n a form similar to Figure 2 -11, NFPA 291 (sample hydrant flow test report).
5. FIRE HYDRANT DISTANCE FROM AN ACCESS ROAD: Fire hydrants shall be
located not more than 15 feet from an approved fire apparatus access roadway.
(UFC Sec. 903.4.2.4
-1 P ici
w ciov n
13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772
Bennett Porter Building Plan Review
PC #: 5-47c BUP #: 98 -0204
Page #2
0 ACCESS AND FIRE FIGHTING WATER SUPPLY DURING CONSTRUCTION:
is Approved fire apparatus access roadways and fire fighting water supplies shall
be installed and operational prior to any other construction on the site or
subdivision. (UFC Sec. 8704)
o�t7 �f• ^�.c ". s� "`° // � ,��'{°� i''/'�'✓� �:�if' /;'jf / % / %�� /'.�j " /jam /, /'ri'; i/ �, /�r.�.. r�%" "�^ /i
?? 'S�i f ICI .% �l l' � /,C �' / // ` j� /i /%/,Gi:S'; /YY . ' » i J2
s','i�g i'�° , / � .rf I'll � /. //,,c�9' /lrfh„i3Y'G' / =l '' /�� /� /`���:r% / % % /r� /.v; :.!n /i�i".;,..cuC r:�, ,... ,��7Yi;�i ��i`•'
1. Drawing C1 indicates the installation of a trench drain. We interpret this to be a
drywall requiring compliance with OPSC, Section 1107.1.2 and 3. Provide
• op details showing compliance. •
n .71' O .',`{';, ml rS '?L';;" F i � /� ,/ <� %/ /'%% Vii, �'� / i / /r.' /,',,% r ✓r �iirr / o /
; ....?rie , ,,A; , p, y fi ,,,, J./ /j / Vi/ r / 7 i� i ,,,, > i� '�. kt.: ` // XI.i' A
i�.^'J;'r • 1J 'r1 /�., �l� / '/,// ii //,if� / / %����iriti'#'f „ %/i%�f t"�� 5''�4ta� 5,8�.'' '�
1. The following walls exceed the maximum glazing allowed by OSSC, Table 13F:
A. North elevation - allowed 380 sq. ft., shown 538 sq. ft.
B. East elevation - allowed 210 sq. ft., shown 395 sq. ft.
C. West elevation - allowed 210 sq. ft., shown 382 sq. ft.
2. Submit completed Energy Compliance Forms 2a, 3a, 3b, 4a through 4j, and 5a
through 5c from the April 1, 1996 Revised Oregon Energy Code.
3. Your lighting loads for each tenant space exceed those allowed by OSSC, Table
• 13R.
f 1I , v {/ .'” ; Y . 0 :::v 7 /' �7 y .'•, % ;. ,-, i nn "
, ,,, "i;: T; / / /'7 / % ; i:G .5 fi ..
x �� �t; � , „i , r y; % /� j / � ! /�i �.�,r % / /i /i /i% � /`� %:�'�� /, :� s�'� �q's�(?';Gr" y r�.�«
4" f / .s lF l � � / / /• wo A a 1 //. � fI ,,, mil. L'.,6 �YJ2
�Y/ �` � �C...,: �/ r l.?./ , a/// �. c3'. � :: iil. fS; 3; �., �// ir i��/.. �/� / /<,•£!.l�� % F� v ��K�: 1 � ; `� /{ r�•
1. Roof drains are not sized correctly. Contact Mike Sheehan, Senior Plumbing
Inspector for further information at 639 -4171, ext. 312.
r� � �'�.rij.',��//�iX "Y %%T %;� "' >. .'�'. /:i :'� %ii /r .// •r. .q'." :i' �i:R?!'',v �:!: '2:;' °::�r%v:$
o tti ,..:•0iif / ZZ /y a Y l r r / r / ig�i i / ' / g r J ' k '� / j�`� / x
'l.�!v;;r/rsz ,:f'29.r9.c / i /::., �,. .,...'S .... � .. i/.,..,.. / /r %� %� / i� / � %l % / �a..l!t...� >. ;� r.y�u. ivl`f�,•i `,3Z;� /�oi� //r. �, � .
1. A separate demo permit will be required to remove the existing house on your
. site.
2. This permit does not include tenant improvements other than those shown under
this permit.
4S .,;,=,..-,, l
t, { 7 W 3,.) . ,,. Y r f j r / v { , S d r� l / . - 7.
,p ,� w3 ' r Ny i" ,, }/ 4 r ' ° ` 55 ? l �' 4E l,.t/S.1 ti}� ° /r�v yr;j5p3 s,,
.: ,. hb�jS / >6� t .. . /. /' / ,.� �, "+ t .. � i /$ /} ! ... y ,. - ,t rk �j?Sl :�SiJa /l��7n�'r''3�.... .4
1. Complete the enclosed Structural Special Inspection form designating an
Approved Testing Laboratory [Line B] and signed by the owner of the project
[Line D].
Bennett Porter Building Plan Review
PC #: 5-47c BUP #: 98 -0204
Page #3
A. The completed form must be retumed to this office before a building
permit can be issued.
B. Copies of all special inspection reports shall be filed with this office
continually during construction.
C. Final signed report must be on file before an occupancy certificate will be
issued [OSSC, Section 1701.3].
%%`. vas !n a mm+??. ox; rrr/,:,• �, s';tF�/,:l,;egg� %% / /��i % %: kosomr3sk�a�,•,e:%;ft�:�^'r«� �5>`s ?ui
Separate applications and permits will be required.
Please submit three copies of revised submittal documents and a letter indicating your
response to the above comments for review. Please call me at (503) 639 -4171 if you
have any questions.
Sincerely,
i t h i t
ert Poskin, CBO
SENIOR PLANS EXAMINER