Plans 9 : .1: w - 00 i i c t Bulletin 136 Rev.O NM I ® Model F1 F e_D__ Model F1FR Recessed 5. 1 Quick Response 0 Sprinklers Model F1FR Sprinkler Types " =-. 1 r - 4 Standard Upright SEP 2 01( : .> Standard Pendent Conventional CITY OF TIGARD 1 �''" Vertical Sidewall BUILDING DIVISION 3 a ' Horizontal Sidewall S' 1 - HSW 1 Deflector `�' Model F1FR Recessed Sprinkler Types F - , R Pendent Recessed Horizontal Sidewall upright Pendent - HSW 1 Deflector Listings & Approvals , 1. Listed by Underwriters Laboratories, Inc. (UL) , 2. Listed b Underwriters' Laboratories of Canada (ULC) rx z fit. 3. Certified by FM Approvals l 4. Loss Prevention Council (LPC, UK) --_ ----- — 5. NYC BS&A No. 587 -75 -SA : = ° ` 6. Meets MILS -901C and MIL -STD 167 -1 -1 1 7. Verband der Schadenversicherer (VdS, Germany) g 8. NYC MEA 258 -93 -E UL Listing Category Vertical Sidewall Conventional Sprinklers, Automatic & Open Quick Response Sprinkler UL Guide Number VNIV ,00'• Patents: US Patent No. 6,374,920 Applies to a . Model F1 FR Vertical Sidewall Sprinklers. .' Product Description Horizontal Sidewall Recessed Pendent Reliable Models F1FR and F1FR Recessed Sprinklers are HSW 1 Deflector (Model FP Shown) quick response sprinklers which combine the durability of a pands, forcing the bubble smaller and smaller as the liquid standard sprinkler with the attractive low profile of a decorative pressure increases. Continued heating forces the liquid to sprinkler. push out against the bulb, causing the glass to shatter, The Models F1FR and F1FR Recessed automatic sprinklers opening the waterway and allowing the deflector to distrib- utilize a 3.0 mm frangible glass bulb. These sprinklers have ute the discharging water. demonstrated response times in laboratory tests which are five to ten times faster than standard response sprinklers. This Application quick response enables the Model F1FR and F1FR Recessed Quick response sprinklers are used in fixed fire protec- sprinklers to apply water to a fire much faster than standard tion systems: Wet, Dry, Deluge or Preaction. Care must be sprinklers of the same temperature rating. exercised that the orifice size, temperature rating, deflector The glass bulb consists of an accurately controlled amount style and sprinkler type are in accordance with the latest of special fluid hermetically sealed inside a precisely manu- published standards of the National Fire Protection Asso- factured glass capsule. This glass bulb is specially con- ciation or the approving Authority Having Jurisdiction. structed to provide fast thermal response. The balance of Quick response sprinklers are intended for installation as parts are made of brass, copper and beryllium nickel. specified in NFPA 13, FM Global Loss Prevention Data At normal temperatures, the glass bulb contains the fluid Sheet 2 -8N or other applicable standards. Quick response in both the liquid and vapor phases. The vapor phase can sprinklers and standard response sprinklers should not be be seen as a small bubble. As heat is applied, the liquid ex- intermixed. The Reliable Automatic Sprinkler Co., Inc. 103 Fairview Park Drive, Elmsford, New York 10523 j i Model F1 FR Quick Response Upright, Pendent & Conventional Sprinklers Installation Wrench: Model D Sprinkler Wrench Installation Data: K Factor Sprinkler Identification Sprinkler Type Sprinkler Approval Number (SIN) US Metric Height Organization SSU SSP Standard - Upright (SSU) and Pendent (SSP) Deflectors Marked to Indicate Position /," (15mm) Standard Orifice with X" NPT (RX) Thread 5.6 80 1 2.2" (56mm) 12,3,4,5,6, 7 R3625 R3615 1 42' (20mm) Large Orifice with %" NPT (R %)Thread 8.0 115 I 2.3" (58mm) 12,3,4,7,8 R3622 1 R3612 /5' (17mm) Small Orifice with y," NPT (R3) Thread 4.2 60 I 2.2" (56mm) 1,2,8 R3623 R3613 X" (10mm) Small Orifice with X" NPT (RX) Thread 2.8 40 I 2.2" (56mm) 1,2,8 R3621 R3611 10mm Orifice XLH with R%" Thread 4.2 60 1 56mm 4,6,7 R3624 R3614 Conventional- Install in Upright or Pendent Position l Omm Orifice XLH with R% Thread 4.2 60 1 56mm — R3674 15mm Standard Orifice with }Z" NPT (R3) Thread 5.6 80 1 56mm 4,6,7 R3675 20mm Large Orifice with 3 /4" NPT (R %)Thread 8.0 115 1 58mm 4,7 R3672 t' 1 Polyester coated upright UL and ULC listed corrosion resistant. �I trw Ut4 a t ` a , N Vi; Upright • Pendent Conventional Model F1 FR Quick Response Recessed Pendent Sprinkler Installation Wrench: Model GFR1 Sprinkler Wrench Installation Data: Nominal Thread K Factor Sprinkler Approval Sprinkler Identification Orifice Size US Metric Height Organizations Number (SIN) X" (15mm) X" NPT (R'h) 5.6 80 2.2" (56mm) 1,2,3,4,5,7,8 R3615 1 %2' (20mm) 34' NPT (R3/4) 8.0 115 2.3" (58mm) 1,2,3,8 R3612 T,fi' (11mm) y" NPT (R') 4.2 60 L 2.2" (56mm) 1,2,8 R3613 3 4" (10mm) 34" NPT (R'h) 2.8 40 2.2" (56mm) 1,2,8 R3611 10mm R% 4.2 60 56mm 4,7 R3614 (11 Refer to escutcheon data table for approvals and dimensions. 7 1 /� HDLE Du. f- 2 5/8" DIA. [68.7mm) — ON. � — ( NOL) HOLE IN CEILING t 15/16' OA -. 2 5/16' DIA. [58.7mm) - �— [49.2 CUP T = l= _ _ ____r �� 1 r 1' X I/7' RfDUCFR - �- i ' X !/7 .P£DUC£R TURN COLLAR UNTIL TIGHT NNT ADNNST 5 LER WR 805 ENCH 9055 I I \ / OF CEILING 1--- ' ' ..L .L.! F ALF Of �IRINC TO ( - ' O° ADJU.ADJUSTMENT (I) oo.v CEILING ONENS/ON CEILING 70111WIt� a ��� /�� 1 �� � �a� OOSda I FACE OF F1T71NG � ( �` , TO FACE I I . _ ` \ � , DIMENSION � 1/9 t � \\ 1 ; I [J 1mm) ,i� �� 1 1 ,\ 1 27/J2 DIA. 1 ADJUST ME.NT - _ [72 2 ,,,, ) -- I 13.6 - - ■J6FLOS_A (7) REFER 70 FI & F1 ESCUTCHEON DATA TABLE FOR AP AND 01MENSIDN5. (1) REFER TO FP ESCUTCHEON OA74 TABLE FOR APPROVALS AND DIMENSIONS 2. Model F1 FR Quick Response Vertical Sidewall Sprinkler Installation Wrench: Model D Sprinkler Wrench Installation Position: Upright or Pendent Approval Type: Light Hazard Occupancy Installation Data: Nominal Thread K Factor Sprinkler Approval Sprinkler Orifice Size US Metric Height Organizations Identification Number (SIN) ' / z ' 'h" NPT (R'h) 5.6 80 2.2" (56mm) 1, 2, 3, 6.8 R3685 15mm /z" NPT (R'h) 5.6 80 2.2" (56mm) 4 (1) (1) LPC Approval is for Pendent position only * .,.�' . Orientation Deflector to Ceiling _ Dimension (Min. - Max.) Upright 4" - 12" (102mm - 305mm) (111 Pendent 6" - 12" (152mm - 305mm) Vertical Sidewall US Patent No. 6,374,920 Model F1 FR Quick Response Horizontal Sidewall Sprinkler Deflector: HSW 1 Installation Wrench: Model D Sprinkler Wrench Installation Data: K Factor Approval n of n�Hons YID Approval Identification Nominal Thread Sprinkler Orifice Size US Metric Length Light Ordinary Number (SIN) Hazard Hazard y" (15mm) }Z" NPT(R'/) 5.6 80 2.63" (67mm) 1,2,3,5,8 1.2.5,8 R3635 NOTE: UL, ULC and MEA Listing permits use with F1 or F2 recessed escutcheon. FM Approvals do not permit recessed usage ,36,..,-0, -- ; % '17 1 -4C OF = �77trJG TO /// L.___.-1 : 14" " MIN. 5 r - i.i 6•nm? i 1 ` •' r� 4 �2 :,/4" r , ^,c pin :. - e. ^ • .1+) ms 's 1 - •' ∎ �� 1 I - 1 7 1 /e" ^7 ' -;p• Bran 757 =mrtj rc3 I X 7/7•• RE V I 1 JL-Lc_r2° 1 l i — � Horizontal Sidewall s''`" p' '-" — — I " i' 1 - i - -` f ' L,4,+ CCL,.ap _/ L 7r/;;7 ,1G2LNS . 5 , 7//7 \`. ■VPFNC'. 5035. s\• ' ) p_r' 7? = S C U r e , C . E n t . 0,17 r ., -T .I... 5 ..:NO V'._ ,5, ... 3. Installation Quick response sprinklers are intended for installation as tle vacuuming. Remove any sprinkler which has been specified in NFPA 13, FM Global Loss Prevention Data Sheet painted (other than factory applied) or damaged in any 2-8N or other applicable standards. Quick response sprin- way. A stock of spare sprinklers should be maintained to klers and standard response sprinklers should not be inter- allow quick replacement of damaged or operated sprin- mixed. klers. Prior to installation, sprinklers should be maintained The Model F1FR Recessed Quick Response Sprinklers are to in the original cartons and packaging until used to mini - be installed as shown. The Model F1 or F2 Escutcheons illus- mize the potential for damage to sprinklers that would trated are the only recessed escutcheons to be used with the cause improper operation or non - operation. Model F1 FR Sprinklers. The use of any other recessed escutch- eon will void all approvals and negate all warranties. Sprinkler Types When installing Model F1 FR Sprinklers, use the Model D Sprin- Standard Upright kler Wrench. When installing Model F1 FR Recessed Pendent or Standard Pendent Sidewall Sprinklers, use the Model GFR1 Sprinkler Wrench. Any Conventional other type of wrench may damage these sprinklers. Sidewall (Vertical, Horizontal HSW 1) Glass bulb sprinklers have orange bulb protectors to minimize Recessed Pendent bulb damage during shipping, handling and installation. RE- Recessed Horizontal Sidewall HSW1 MOVE THIS PROTECTION AT THE TIME THE SPRINKLER SYSTEM IS PLACED IN SERVICE FOR FIRE PROTECTION. Re- Finishes (1) (2) moval of the protectors before this time may leave the bulb vul- standard Finishes nerable to damage. RASCO wrenches are designed to install sprinkler Escutcheon sprinklers when covers are in place. REMOVE PROTECTORS Bronze Brass BY UNDOING THE CLASP BY HAND. DO NOT USE TOOLS Chrome Plated Chrome Plated (3) TO REMOVE THE PROTECTORS. White Polyester Coated White Painted (3) Temperature Ratings special Application Finishes Sprinider� Ambient Bulb Sprinkler Escutcheon Classification Temperature Max- Color Bright Brass Bright Brass °C °F Black Plated Black Plated Ordinary 57 135 100°F (38°C) Orange Black Paint Black Paint Ordinary 68 155 100°F(38°C) Red Intermediate 79 175 150°F (66°C) Yellow Off White Off White Intermediate 93 2(X) 150°F(66°C) Green Satin Chrome Satin Chrome High (1) 141 286 225°F (107°C) Blue ( Other finishes and colors are available on special order. (1) Not available for recessed sprinklers. Consult the factory for details. Escutcheon Data (2) FM Approvals is limited to bronze and brass, chrome or black plated finishes only. Escutcheon Faced Fitting ( FP Push - on/Thread -off escutcheon. Model APPlovals Actlusenent p ( UL and ULC listed corrosion resistance. 1Nall Dimension SIN numbers: R3621, R3622, R3623, R3625. Max Recess (38.1 mm) ? 6" , Note: For %" orifice pendent FM approved white F1 1,2,4,8 Min Recess 3 , " (5mm -24mm) polyester coated and UL approved white polyester (19.1 mm) corrosion resistant sprinklers refer to Bulletin 014. 1 y „ F 2 1,2,3(1),4,5,7,8 Max Recess (38.1mm) Ys' Xs' Ordering Information Min Recess 'X," (5mm -17mm) Specify: (24mm) Max Re- Xs" 1. Sprinkler Model FP 1.2 cessed (11mm) 1' "(38.1mm) 2. Sprinkler Type Pushonl Thread -off 1,2 Min Recessed ' 56" 1 " (25.4mm) 3. Orifice Size (24mm) 4. Deflector Type No Dimensional Figure for FP 5. Temperature Rating (') Horizontal Sidewall is not FM approved in the reccesed configuration. 6. Sprinkler Finish Maintenance 7. Escutcheon Type The Models F1FR and F1FR Recessed Sprinklers 8. Escutcheon Finish (where applicable) should be inspected quarterly and the sprinkler system maintained in accordance with NFPA 25. Do not clean Note: When Model F1FR Recessed sprinklers are sprinklers with soap and water, ammonia or any other ordered, the sprinklers and escutcheons are packaged cleaning fluids. Remove dust by using a soft brush or gen separately. The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 80 years. and are installed and serviced by the most highly qualified and reputa- ble sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by l .. The Reliable Automatic Sprinkler Co., Inc. a R � c c Reliabit (800)431 -1588 Sales Offices (800)848 Sales Fax Revision lines indicate updated or new data (914)829 2042 Corporate Offices www.rcliablesprinkler.corn Internet Address 60. printed r. U.S.A. 06/09 R1,19:195970027 [Page Too Large for OCR Processing]