Loading...
Report Main Office Salem Office Bend Office P.O. Box 23814 4060 Hudson Ave., NE P.O. Box 7918 Tigard, Oregon 97281 Salem, OR 97301 Bend, OR 97708 Carlson Testing Inc. Phone (503) 684 -3460 Phone (503) 589 -1252 Phone (541) 330 -9155 FAX (503) 684 -0954 FAX (503) 589 1309 FAX (541) 330 -9163 Special Inspection Qom / '5.-.00Z33 FINAL SUMMARY LETTER May 1, 2000 4in T9902536B ` R? �'' �['�T F TJ City of Tigard I MAY 0 2 2000 6 13125 SW Hall Blvd., i Tigard, OR 97223 -5199 f Attn: Building Department Re: Tigard Corporate Center — Building C 12447 SW 69 Tigard, OR Permit No.: BUP1999 -00233 Dear Sir or Madam: This is to certify that in accordance with Section 1701 of the Uniform Building Code and Chapter 24.20, Title 24, we have performed special inspection of the following item(s) per our inspection reports only: Reinforcing Steel Concrete — Compressive Strength Testing Installation of Wedge Anchors Structural Steel — Shop and Field High Strength Bolts Fireproofing All inspections and tests were performed and reported according to the requirements of Project Documents and, to the best of our knowledge, the work was in conformance with the approved plans and specifications, approved change orders and applicable workmanship provisions of the State Building Code and Standards, as well as the structural engineer's design changes, approvals and verbal instructions. Our reports pertain to the material tested /inspected only. Information contained herein is not to be reproduced, except in full, without prior authorization from this office. If there are any further questions regarding this matter, please do not hesitate to contact this office. Res • , ctf submitted, CAR I. • ESTING, I . il Jam= Hietpas Qua ' ssurance Manager JFH:j. cc: Specht Development, Inc. — Bob Bums Baugh Construction Company LRS Architects VLMK P:\WOR D'R EPORTSFlNLTR\T99025398 05/01/00 MON 12:47 FAX 503 884 0954 CARLSON TESTING Q004 Main Office Salem Office Bend Office P O. Box 23814 4060 Hudson Ave., NE P.O. Box 7918 Tigard, Oregon 97281 Salem. OR 97301 Bend OR 97708 Carlson 'I`estin g � �• Phone (503) 884-3480 FAX (603) 684 -0954 Phone (503) 589.1252 Phone (541) 3904155 i FAX (509) 589 -1309 FAX (341) 330 -9963 Special inspection FINAL SUMMARY LETTER May 1, 2000 T9902536B City of Tigard 13125 SW Hall Blvd., Tigard, OR 97223 -8199 Attn: Building Department Re: Tigard Corporate Center — Building C 12447 SW 69 Tigard, OR Permit No.: BUP1999-00233 Dear Sir or Madam: This is to certify that in accordance with Section 1701 of the Uniform Building Code and Chapter 24.20, Title 24, we have performed special inspection of the following item(s) per our inspection reports only: <einforcing Steel Concrete — Compressive Strength Testing Installation of Wedge Anchors ,Biructural Steel — Shop and Field h Strength Bolts reproofing All inspections and tests were performed and reported according to the requirements of Project Documents and, to the best of our knowledge, the work was in conformance with the approved plans and specifications, approved change orders and applicable workmanship provisions of the State Building Code and Standards, as well as the structural engineer's design changes, approvals and verbal instructions. Our reports pertain to the material tested/inspected only. Information contained herein is not to be reproduced, except in full, without prior authorization from this office. If there are any further questions regarding this matter, please do not hesitate to contact this office. Res ' = submitted, CAR !- • ESTING, I . Jam: Hietpas Qua • ssurance Manager JFH:j• cc: Specht Development, Inc, — Bob Bums Baugh Construction Company LRS Architects VLMK •