Specifications V a000 - 0 00 ® 7100 Series FIRE CONTROL INSTRUMENTS COMPACT ANALOG ADDRESSABLE FIRE ALARM CONTROL PANEL DESCRIPTION - r _ The FCI 7100* Series fire alarm control panel effectively — - -- combines multiprocessor analog system advantages with a - -- ....._,.z - s. compact, efficient design. Designed for commercial, Indus- f °.i - trial and institutional use the 7100 compact control panel is P z .. ideal for life safety applications. 'T This analog addressable fire alarm control panel provides . ,,, .atE� one or two signaling line circuits, each capable of accommo- rt `" `'$ dating 99 analog sensors and 98 monitor and/or control points for a total of 197 points per circuit, with a system maximum . . Y of 394 points. . Front -panel intuitive programming eliminates the need for pit computers and software programs, and facilitates the instal- _ lation regardless of the complexity of the application. .; _ $ ; . The sophisticated circuitry and powerful analog software �.'i enables it to read specific (default/user) sensitivity levels of ^ sw each sensor and compensate for any changes due to age or '` ; ; ' environmental conditions. In accordance with the FCI repu' �„1� , , ,' - tation for rugged reliability, the panel is designed to withstand 6000 VAC transients, far in excess of required limits. A single optional module allows Class A operation for both signaling FEATURES line circuits and notification appliance circuits. • Intuitive Front Panel Programming Designed around multi le processors, the 7100 Series fea- • tures the proven ADAC degrade mode of operation that Periodic Alarm and/or Trouble Reminder assures the panel will process alarms if the human interface • 80- character Alphanumeric Display fails or will annunciate total failure if the main system proc- • Manual/Automatic Sensor Settings essor fails. It also incorporates the FCI Listed Integrated • Individual Sensor Drift Compensation Sensitivity Testing (LIST) which meets the NFPA 72 sensi- . Listed Integral Sensitivity Testing (LIST) tivity testing and maintenance requirements. The LIST test- . ing saves substantial time and money in both maintenance • "Dirty" and "Very Dirty" Sensor Indications and service while virtually eliminating unwanted alarms. • Multilevel Sensor Sensitivity Adjustments The four ampere power limited power supply operates on Day/Night Sensor Sensitivity Adjustments • 120 VAC, 50/60 Hz and is capable of maintaining batteries up to 31 ampere/hours in capacity. • Alarm Verification per Individual Sensor Housed in an attractive contemporary styled cabinet, the • RS -232 Serial Port Connection for Modems, 7100 offers ample wiring space for power limited and non - Printers, CRTs, etc. power limited wiring separation, combined with adequate • Four Levels of System Access Programming space for housing batteries up to 7 AH capacity. With Five Passwords per Level • Duplicate Address Indication OPTIONAL MODULES • One or Two Style 4 (Class B) Signaling Line • RS -232 Isolator/Transient Protection Circuits Module for Remote Device Connection • Two Style Y (Class B) Regulated • Class A Combination SLC and NAC Notification Appliance Circuits, Rated 1.5 Amp. each Upgrade Module • March TimelTemporal Pattern/Calif. Code • Municipal Connection Module for City Box • Dual -Mode Walk Test • 500 -Event History Log • Last Date, Time and Menu Option Printout for Programming Verification . • Patent pending ADAC ° is a registered trademark of Fire Control Instruments, Inc. 301 2nd Ave Waltham, MA 02451-1133 USA TEL: (781) 487 -0088 FAX: (781) 370 -4132 9020- 0466/Ver. 1.4 w SPECIFICATIONS Primary input power 120 VAC, 50/60 Hz, 3.0 amps. Output power 4 amp. @ 24 VDC (total) Non - resettable power .250 amp. Resettable power .250 amp. Two (2) Notification Appliance Circuits 1.5 amp. each Operating temperature 32 - 120 F (0 - 49 C) Relative humidity 85% (non- condensing) Battery charger capacity 31 AH Alarm and Trouble relay contacts Form "C ", 2 amps. @ 24 VDC (resistive) Dimensions 16.9" H x 14.5" W x 3" D (40 x 37 x 7.5 cm) Weight 24 lbs (11 kg) ORDERING INFORMATION Part Number Model Description 1100 -123 100 -1 Analog Addressable Control Panel, with one (1) Signaling Line Circuit 1100 -1236 7100 -2 Analog Addressable Control Panel, with two (2) Signaling Line Circuits 1120 -0787 EN -7100 Back Box ( 1120 -0779 CS -7100 Door 1120 -0783 BSM -1 Basic System Module, 1 SLC (replacement) 1120 -0781 BSM -2 Basic System Module, 2 SLC (replacement) 1120 -0778 T -7100 Transformer (replacement) 1100 -1233 CAOM Class A option combination module for both signaling line circuits . and notification appliance circuits 1100 -1234 MCOM Municipal Connection Module for Local Energy City Box 1100 -1235 PTRM Printer Transient Module for remote EDP device connection • CI Specifications are provided for information onl% are not Intended to be used for installation purposes, and are believed to be accurate. However, no responsibility is assumed by Fire Control Instruments, Inc. for their use. Specifications subject to change without notice. • 0 1999 All Rights Reserved 2 of 2 9020 -0466 ASD -PL SERIES FIRE CONTROL INSTRUMENTS LOW PROFILE ANALOG ADDRESSABLE PHOTOELECTRONIC SENSOR APPROVED DESCRIPTION The FCI Model ASD -PL Low Profile Analog Addressable Photoelectronic Sensor is 1.7- inches high when mounted in a standard base, thus presenting a very low profile suitable for installation where architectural requirements are a prime concern. The sensor is continually monitored to measure any change - — in its sensitivity due to the environment (dirt, smoke, + (11111 temperature, humidity, etc.). It can give an advance indication to the control panel of the need for maintenance and can be specific as to where the maintenance is needed. If local regulations permit, then selected maintenance may be performed as opposed to having to check the sensitivity of all sensors to assure overall performance when only a few may be dirty. FEATURES Designed to operate in conjunction with the FCI Analog Addressable Fire Alarm controls, the ASD -PL sensor • Compatible with FCI Analog transmits an analog value representative of the sensitivity that Addressable Control Panels can be used by the system to determine when maintenance is required. Signal processing for alarm verification is built into • Low Profile Construction the system to provide immunity to false alarms. • Easy plug -in of the Head to Base The sensor is of plug -in construction and is directly interchangeable in the same base with the ASD -IL analog • Built -in Signal Processing ionization and ATD /ATD -R thermal sensors. A wide variety • Built -in Tamper - Resistant Feature of bases, with sounder, relay, etc., is available. Remote LED annunciator capability is also available as an optional • Remote Test Feature (From the Panel) accessory. • Built -in Test Switch The ASD -PL detector is Listed for use inside ducts up to a • velocity of 4,000 FPM. • 360 View Angle of Dual Alarm LEDs The sensor may be tested from the control panel, or functional testing can be performed by applying a test magnet • Removable Insect Screen and Cover according to the test procedures. for Field Cleaning An optional isolator base, Model B224BI, is also available. • Sealed against Dirt, Insects, and Installation of two of these isolator bases allows Style 7 Back Pressure operation for all sensors located between the bases. • Optional Bases for Auxiliary Functions • Maximum Air Velocity 4,000 FPM TECHNICAL SPECIFICATIONS Operating Voltage 15 -32 VDC Standby Current (Sensor) 230 uA (without communication) 330 uA (one communication every 5 sec. with LED enabled) Alarm Current (max.)(LED lit) .007 amp. Remote LED current .007 amp. Operating/Installation Temperature 32 F - 120 F (0 C - 49 C) Operating Humidity 10% to 93% relative humidity (non condensing) Dimensions 1.7" H x 6.2" Dia. (In standard base) Weight 3.6 oz. 301 2nd Ave Waltham, MA 02451 -1133 USA TEL: (781) 487 -0088 FAX: (781) 370 -4132 9020- 0373Ner. 1.3 Fire Control Instruments, Inc. SENSOR COVER { INSTALLATION Place the sensor into the sensor base. Turn the sensor clockwise until the sensor locks into place. To use the tamper -proof feature, break the smaller tab 0 0 I►1' on the base as shown in the installation instructions. lJ Install the sensor. To remove the sensor from the base COVER when using the tamper -proof feature, insert the blade of REMOVAL a small screwdriver into the hole on the side of the base TABS SENSOR SCREEN and push the plastic lever away from the detector head. ;�; • This will allow the sensor to be rotated counterclockwise for removal. NOTE: The decorative • • • • • =''�' -''�"''�'�'�' ring must be removed in order to remove the head when SCREEN • using the tamper -proof feature. PC BOARD 1 CONTACTS SENSING CONTACT CHAMBER Refer to NFPA 72, Chapter 5 -3 "Smoke Sensing Fire Detectors" for spacing, location of sensors and other , Mir . guidelines. =1= _ 1 TESTING II'Y ❑ Sensors may be tested locally in the following ways: MAINTENANCE • A. Place a test magnet against the sensor housing per the installation instructions. The Cleaning programs should be adapted to the sensor should go into alarm within 30 seconds. individual environment in conformance with the National Fire Alarm Code, NFPA 72. We recommend, • B. Field metering of sensor sensitivity may be at the least, an annual cleaning of the unit. The sensor performed with the aid of a voltmeter and Test screen and cover assembly can be removed, revealing C Kit, P/N 119- 9010N. For the complete the sensing chamber. A vacuum cleaner can be used to procedure, refer to the instructions furnished remove dust from the screen, cover and sensing with each test kit. chamber. For the complete procedure, refer to the • C. Aerosol Generator - The Gemini Model Installation and Maintenance Instructions furnished 501 aerosol generator may be used to perform with each sensor. a functional test. Follow instructions in the generator instruction manual. AGENCY APPROVALS • D. Sensor sensitivity may be tested and measured at the control unit. Refer to the UL (Std 268) S1913 control panel operating manual. ORDERING INFORMATION Part No. odel Description 110-90001 ASD -PL Low Profile Analog Photoelectronic Sensor • 110 -90005 B -FL Standard plug -in sensor base with flange and decorative ring 110 -90004 B224RB Plug -in sensor base with auxiliary relay, SPDT, rated 2 amps. @ 30 VDC (resistive) 110 -90006 B224BI Plug -in sensor isolator base for Style 7 operation 130 -3100G B501BH Plug -in sensor base with sounder 110-31A60 B501 Plug -in sensor base w/o flange 138 -01005 RA -400Z Remote alarm indicator 119 -9010N Detector sensitivity test kit. Specifications are provided for information only and are believed to be accurate. However, no responsibility Is assumed by Fire Control Instruments, Inc. for their use. Specifications subject to change without notice. 01997 All Rights Reserved 2 of 2 • 9020 -0373 Addressable Modules \k EVE irlq# � Z j 1 ti T. ADDRESSABLE MONITOR MODULE ADDRESSABLE MONITOR MODULE (AMM -4, AMM -4S) (AMM -2) The Addressable Monitor Module AMM -4 provides an The Addressable Monitor Module AMM -2 provides an address for a group of UL Listed normally open (N.O.) address for a group of UL Listed normally open (N.O.) initiating devices, such as heat detector, beam smoke initiating devices, such as heat detector, projected beam detector, 4 -wire smoke detector, waterflow switch, manual smoke detector, 4 -wire smoke detector, waterflow switch, station, etc. wired in a Class A, Style D or Class B, Style B manual station, etc. wired in a Class B, Style B initiating initiating circuit. The AMM -4S (non -FM) also allows the use circuit. of multiple, conventional 2 -wire smoke detectors in the circuit. EJ 0 , 01 (.> at x� 1 & 12_ �� 1 G T ADDRESSABLE OUTPUT MODULE FAULT INDICATOR MODULE (AOM -2) (M500X) The Addressable Output Module connects to the same loop The optional M500X Fault Indicator Module is used to as the initiating devices and provides a form "C" relay output, protect the system against wire -to -wire short circuits on the or notification appliance circuit, which may be programmed signaling line circuits. The modules should be spaced to operate from either a trouble or alarm input from any between groups of sensors in a circuit to protect the rest of addressable device. An external 24 VDC power source is the circuit. In the event of a short circuit between any two required when the module is configured as a notification fault indicator modules, then both modules immediately appliance circuit module, which can be configured as Class switch to an open circuit condition and isolate any groups of B, Style Y or Class A, Style Z. The module contains an LED sensors between them. The remaining units on the circuit will which can be latched on by code command from the panel. continue to operate in a normal fashion. In a Style 4 circuit, the module is generally used at each `T- -tap" branch. The module has an LED indicator that lights continuously during a short circuit condition. 9020 -0348 3 of 4 FIRE CONTROL INSTRUMENTS, Inc. TECHNICAL AND ORDERING INFORMATION Part No. Model Description Supervisory Alarm Current Current SENSORS 110-31060 ASD -I Analog Ionization smoke sensor .00030 amp. .007 amp. 110 -90002 ASD -IL Low Profile Analog Ion. smoke sensor .00030 amp. .007 amp. 110 -3106J ASD -P Analog Photoelectronic smoke sensor .00015 amp. .007 amp. 110 -90001 ASD -PL Low Profile Analog Photo. smoke sensor .00033 amp. .007 amp. • 112 -3219I 2551T Analog Photoelectronic smoke sensor with 135 F thermal unit .00015 amp. .007 amp. 114 -22020 ATD Analog Thermal fixed temp. • 135 F. sensor .00020 amp. .007 amp. 115 -91120 ATD -R Analog Thermal combination fixed temp. 135 F. and Rate of Rise sensor .00020 amp. .007 amp. MODULES 190 -00002 AMM -2 Addressable Monitor Module (N /O devices, Style B only) .0004 amp. .007 amp. 190 -00003 AMM -4 Addressable Monitor Module (N /O devices, Style D or B) .0004 amp. .007 amp. 190 -00013 AMM -4S Addressable Sub -Loop Monitor Module (2 -wire detectors, Style D or B)(non -FM) .0004 amp. .043 amp. 190 -00010 AOM -2 Addressable Output Module .0004 amp. .007 amp. 190 -00100 M500X Fault Isolator Module .00045 amp. .005 amp. 252 -90001 MB500 Module mounting bracket (Holds up to 8 AMM/AOM modules) BASES, ACCESSORIES - (ASD -I, ASD -P, ATD, ATD -R, 2551T) 110 -31A60 B -501 Plug -in base, 4- inches diameter 112 -31B60 ADB -F Plug -in base, flanged, 6.2- inches diameter 130 -3100G B501B Horn assembly unit (includes base) .0011 amp. .0115 amp. 110 -3136K B524RB Plug -in base,flanged, with auxiliary relay, • SPDT, rated 2 amps. @ 30 VDC (resistive) .0007 amp. 110 -90015 B524BI Plug -in isolator base for Style 7 operation .0007 amp. .005 amp. . 110-38060 DHSO0 w /rel* . Duct housing with relays .026 amp. .087 amp. 119 -A0300 DHSO0 w/o rel* Duct housing less relays .00015 amp. .006 amp. 138 -01005 RA -400Z Remote alarm indicator (mounts on single gang box) .007 amp. 119 -5310P RTS451** Remote test switch with Alarm LED .007 amp. 119-90018 RTS451KEY ** Key operated test switch with Alarm LED .012 amp. .007 amp. * Use with ASD -I or ASD -P only ** Requires 24 VDC external source of power BASES - (ASD -IL, ASD -PL) 110 -90005 ADB -FL Plug -in base, flanged, with decorative ring 110 -90004 B224RB Plug -in base with auxiliary relay, SPDT, rated 2 amps. @ 30 VDC (resistive) .0007 amp. 110 -90006 B224BI Plug -in isolator base for Style 7 operation .0007 amp. .005 amp. NOTE: Low profile sensors ASD -IL and ASD -PL may be used with B501, B501BH and RA -400Z. 0 Specifications are provided for information only and are believed to be accurate. However, no responsibility is assumed by Fire Control Instruments, Inc. for their use. 0 Specifications subject to change without notice. 0 1997 All Rights Reserved 4 of 4 9020 -0348 FC1 MS SERIES 4 FIRECONTROL INSTRUMENTS NON - CODED, MANUAL FIRE ALARM STATIONS itt APPROVED Model MS -2, MS -2H. The MS -2 manual fire alarm stations are double action ' �` qtr? devices. These stations requires that the outer door be lifted � oRe to expose the actuation door which is then pulled forward to 14 1 M , ,. , ; • operate the alarm toggle switch. The actuation door is now I t;. : -" , 1 , locked in the readily observable "alarm" position. To reset the station, a key ( common to FCI control panels) must be inserted and turned 1/4 turn clockwise, opening the MS - MS - 2H station. Closing the station resets the switch automatically. An optional breakglass rod is available for positive indica- . tion of station operation. _ PULL' I t 'F; 1 Model MS -2P (Presignal) ► FIRE Operation of the Model MS -2P presignal station is similar { to that of the MS -2, with the addition of a key- operated switch FIRE! mounted on the lower door. This switch may be used for ALARM' r id "general alarm" signaling. PULL Model MS -2L, MS -2LP Institutional = N.- ( ) M6 . S - MS -WS Operation of the Model MS -2L institutional station re- quires that a special key be used to release the actuation door before it can be operated. This lock may be keyed as required • by the particular application. The MS -2LP features an addi- FEATURES tional key- operated switch mounted on the lower door. • Single and Double Action Versions Model MS -2 -D (Multiple Contact) • Tumbler Lock for Test and Reset The MS -2 -D features a DPST switch for multiple signaling Keyed Alike with FCI Controls via wire lead connections. • Positive Indication of Operation over Model MS -6 (Single Action) 180° Viewing Angle The MS -6 station is a single action device, requiring only • Surface or Semi -flush Mounting the pulling of the action door to release the compressed (MS -2, MS -6) button switch. It is available either with terminals (MS -6T) or wire leads (MS -6). • Shock and Vibration Resistant The station resets in the same manner as the MS -2. The reset • NEMA 3 Weatherproof Version key is common to FCI control panels. (MS -WS) Model MS - (Weatherproof) • Institutional Version (MS -2L) The surface mounted cast aluminum MS -WS station has a • Institutional Presignal Version protective hood over the actuation door which offers genuine (MS -2LP) NEMA 3 weatherproof construction. The pull door is held in place by a breakglass rod and extends below the body of the • Presignal Version (MS -2P) station so it can be pulled outward to operate even if ice coated. The reset key is common to FCI control panels. • Optional "FIRE SUPPRESSION The surface mount backbox is threaded for 1/2 -inch (12.7 SYSTEM RELEASE" Markings mm) conduit fittings both on top and bottom. (MS -2H) • Optional DPST Switch (MS -2 -D) r ,, Specifications are provided for information only and are believed to be accurate. However, no responsibility is assumed by Fire Control Instruments, Inc. for their use. Specifications subject to change without notice. 0 1997 All Rights Reserved 301 2nd Ave Waltham, MA 02451 -1133 USA TEL: (781) 487 -0088 FAX: (781) 370 -4132 9020- 0358/Ver. 1.5 (. ` "ExlsO Work' Swhchbox .n ... 1 1/2" x) . 81 anj mla depM 4 Model BB -2 Bodice Badrbox AGENCY APPROVALS UL (Std 38) File S2465 FM (MS -2, MS -WS) 0J3A9.AY/12880 (MS -6, MS -6T) 1 D4A7.AY C.S.F.M. (MS -2, MS -6) 7150- 0694:107 (MS -WS) 7150- 0694:136 NYC BS &A (MS -2, MS -WS) 960 -81 -SA NYC MEA (MS -6) 103 -93 -E SPECIFICATIONS - Material (MS -2, MS -6) Extruded 6063/T5 aluminum • Doors (MS -2, MS -6) Clear anodize Switch type MS -2 Enclosed toggle MS -6, MS -WS Enclosed push button Contact material Silver plated bronze or copper • Contact ratings MS -2 6 amp. max. @ 30 VDC (resistive) MS -6 0.5 amp. max. @ 30 VDC (resistive) MS -WS 3 amp. @ 30 VDC (resistive) Dimensions (overall) MS-2, MS -6 5" H x 3.4" W x 2.8" D (12.7 cm x 8.64 cm x 7.11 cm.) MS -WS 5.8" H x 3.5"W x 2.75" D (14.73 cm x 8.89 cm x 6.99 cm ) ORDERING INFORMATION Part No. Model Description 1100 -0615 MS -2 Double action fire alarm station 1100 -0634 MS -2H Double action station with "FIRE SUPPRESSION SYSTEM RELEASE" markings 1100 -0619 MS -2P Presignal fire alarm station 1100 -0621 MS -2L Institutional fire alarm station 1100 -1096 MS -2LP Institutional presignal fire alarm station 1100 -0617 MS -2 -D Double action station with DPST switch 1100 -0632 MS -6 Single action station, wire leads 1100 -0633 MS -6T Single action station, terminals 2520 -0023 BB -2 Surface back box for MS -2, MS -6 stations 1120 -0206 Package of two replacement breakglass rods For MS -2 station 120 -1312G MS -WS Weatherproof station with surface backbox 2500 -0247 GR -1 Replacement glass rod for MS -WS 2 of 2 9020 -0358 MI ® 600 SERIES (20 FIRE CONT INSTRUMENTS AND RATE o RISE HEAT DETECTORS APPROVED DESCRIPTION The 600 series heat detectors provide reliable dual - action detection in an attractive low- profile package that protrudes • only 1 3/8" from the ceiling surface. Smooth, pleasing contours and an all white finish blend in with most ceiling `` <• designs. The rate of rise feature detects fires that grow rapidly . in intensity by quickly responding when the rate of temperature rise exceeds 15 F (9 C) per minute. The fixed temperature element operates independently of j j the rate of rise feature and uses a fusible alloy. When �` '/ activated, the external heat collector drops away to provide % quick visual confirmation that the element has operated. . A patented reversible mounting plate is supplied with each / detector. In one position it attaches to a 3 1/4 or 4 -inch octagon box or a plaster ring. In the other position, it can be used for open wiring without junction boxes. The different models are marked with unique paint schemes on the heat collector. The detector is 4 9/16" diameter by 1 3/8" high flush mounted, and 1 9/16" high surface mounted. FEATURES APPROVALS • Attractive Low Silhouette Design ' - U.L. (Std 521) File S2332 • Easy to Install F.M. Approved • Dual action - uses Two, Independent C.S.F.M. 7270- 0061:005 Detection Methods NYC BS &A 6 -87 -SA • 2- circuit Models Available APPLICATION INFORMATION Model Description Max. spacing allowed Marking Code 601, 621 Comb. FT +ROR, 135 (57 C) 50 x 50 ft (UL) 30 x 30 ft (FM) None 602, 622 Comb. FT +ROR, 200 F (93 C) 50 x 50 ft (UL) 30 x 30 ft (FM) Gray ring 603, 623 Fixed temp. only, 135 F (57 C) 25 x 25 ft (UL) 20 x 20 ft (FM) Gray spot 604, 624 Fixed temp. only, 200 F (93 C) 15 x 15 ft (UL) 15 x 15 ft (FM) Gray spot &ring ORDERING INFORMATION AND SPECIFICATIONS Part No. Model Description Contact Type 115 -1112C 601 Comb. 135 FT + ROR SPST 115 -1122C 621 Comb. 135 FT + ROR DPST 115 -1412C 602 Comb. 200 FT + ROR SPST 115 -1422C 622 Comb. 200 FT + ROR DPST 115-111/c FT 135 only SPST 115 -1124C 623 FT 135 only DPST 115 -1414C 604 FT 200 only SPST 115 -1424C 624 FT 200 only DPST _: All contacts rated 1.0 ampere @ 6-28 VDC (resistive) Specifications are provided for information only and are believed to be accurate. However, no responsibility is assumed by Fire Control Instruments, Inc. for their use. Specifications subject to change without notice. 0 1997 All Rights Reserved 301 2nd Ave Waltham, MA 02451 -1133 USA TEL: (781) 487 -0088 FAX: (781) 370 -4132 9020- 0036/Ver. 1.3 whe.elo L� r;1 L` INC. FIRE ALARM SYSTEMS ADA , SERIES AS AUDIBLE STROBE APPLIANCES • SERIES AH Description AUDIBLE APPLIANCES Wheelock's Patented 2 WIRE Series ASludible Strobe Appliance(s) and Series AH Audibles offer more features with Less Current and Zero Inrush. The audible provides aSe /ectab /e choice of either acontinuous , ` , °' yr qv le ma NIF horn tone or temporal pattern (code 3) tone when constant voltage from ,k - A „ F • a Fire Alarm Control Panel (FACP) is applied. Each tone has 3 dBA " 41 r G s , • - _ ' - settings to choose from. All models (audible only or audible /strobe) may be Synchronized when used in conjunction with the Series SM or DSM j s � s`la �. ',-- Sync Module. Additionally, the audib /e may be silenced while maintaining strobe activation on combination Series AS units. ,; ` The Series AS Audible Strobes and AH Audibles are designed for Y ' maximum performance, reliability, and cost - effectiveness while meeting - L, or exceeding the latest requirements of NFPA 72 (National Fire Alarm " . '" .I a Code), ANSI 117.1 (American National Standard for Accessible and T __ e.44 Usable Buildings and Facilities) UL Standard 1971 (Standard for Signaling Devices for The Hearing Impaired) and UL 464 (Audible Signal UNIVERSAL MOUNTING PLATE HORIZONTALLY MOUNTED STROBE Appliances). Series AS Audible Strobe Appliances, when properly (15,15/75,30,75 & 110 cd) specified and installed in accordance with NFPA/ANSI standards can (shown as wall mount) provide the Equivalent Facilitation allowed under ADA Accessibility Guidelines (ADAAG General Section 2.2) by meeting or exceeding the illumination which results from the ADA specified strobe intensity of 75 •, candela at 50 feet. This is an illumination of .030 lumens per square foot. ... "• ; - When used with the Wheelock Series SM or DSM Sync Module, - *, synchronization of the continuous horn tone provides thdemporal (code = 3 mandated Y N FPA -72 (1993 )with ( ) Y tone b with an effective date ofJuly '9 . p " ..-.-- . - simultaneously for all audible appliances. This ensures a distinct temporal : (code 3) pattern when 2 or more audibles are within hearing distance. If z .. Y "' " ' � - '1 not synchronized the temporal sound could overlap and not be distinctive. At the same time the strobes will be synchronized. This provides the ability 1 ' - - ---- -°° , , to comply with ADA recommendations concerning photosensitive ,,„ ;;, r � . epilepsy and NFPA standards when installing 2 or more visual appliances .. .a within the field of view.Allo / this plus the ability to silence the audib /e is achieved by using only 2 WIRES. SERIES AH SERIES AH -WP • (Indoor only) (weatherproof) Features . SERIES AS Audible Strobes and Series AH Audible Appliances • Approvals Include: Underwriters Laboratories UL 1971 and UL464 • SERIES AS Audible Strobe Appliancesare available in Wall and Listings, FCC Part 15, European Community (CE), New York City Ceiling mount models. (MEA), California State Fire Marshal (CSFM), Pending: Chicago (BFP) • Wall mountavailable in 15, 15/75, 30, 75 and 110 candelatensity. and Factory Mutual (FM). The 15/75 candela wall mounted strobes are listed at 15 candela • ADA/NFPA/ANSI compliant. Meets OSHA 29 Part 1910.165. under UL Standard 1971 and meet 75 candela intensity on axis for • LOW CURRENT. ADA guidelines with low current draw. • ZERO INRUSH • Ceiling mount available in 15, 30, 75 and 100 candeleensity. • PATENTED 2- WireAppliance. • All models can be Synchronized by adding the Series SM or DSM • Selectable Continuous Horn or Temporapcode 3) Tones. Sync Module to the NAC circuit. • 3 Selectable dBA levels in both tones. • Sync the Audible - Maintain the Temporal Pattern when 2 or more • Continuous Tone: Anechoic; 90, 95, 99 dBAeverberant 82, 88, appliances are in an area. Meets NFPA requirement for Temporal or 91 dBA. Evacuation Notification. • Temporal (Code 3) Tone: Anechoic; 90, 95, 99 dBWeverberant • Sync the Strobe - Maintain True 1 Flash per second when using 2 75, 82 or 85 dBA. or more visual appliances within the field of view. Meets ADA and • Patented Universal Mounting Plate flows mounting to single gang, NFPA. double gang, 4• square, 100 mm European backboxes or the SHBB • Ability to Silence the Audiblevhile maintaining the strobe flash. surface backbox. • ALL FEATURES ON 2- WIRES! • Mounting Accessory "NATP" Notification Appliance Trim Plate • 12 and 24 volt models available. available for use when there is open space between the finished wall and the flush backbox. • SERIES AH Audible Appliancesare available in two models. • AH -12 or AH -24 Indoor Audible Horn Enclosed in a matching grille to the Series AS. ( = • AH -12WP or AH -24WP can be installed indoor or outdoor (weatherproof). When used outdoor, must be used with a WBB- �' ' Weatherproof Backbox. Copyright 1998 Wheelock, Inc. All rights reserved. NOTE: All CAUTIONS and WARNINGS are identified by the syrtkolAll warnings are printed in bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPIMMG PRODUCT. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS AND WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALIAIOIOOR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND /OR OTHERS !neral Notes: strobes are designed to flash at 1 flash per second minimum from 20 -31 VDC. (for 24 VDC models) or 10.5 -15.6 VDC (for 12 VDCdets). Note that NFPA -72 (1996) specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flaslpor second. • All candela ratings represent minimum effective Strobe intensity based on UL 1971. • Series AS Strobe products are UL 1971 for indoor use with a temperature range of 32° F to 120° F (0° C to 49° C) and maximum hurttjcbf 85 %. • Series AH -12 and AH -24 horns are listed under UL 464 for audible signal appliances (Indoor use only). • Series AH -12WP and AH -24WP audible appliance are Listed under UL 464 for indoor /outdoor use with a temperature range of -31 °F to 150 °F ( -35 °C to 66 °C) maximum humidity of 95 %. Specifications and Ordering Information WALL MOUNT AUDIBLE STROBES Input AVERAGE CURRENT (Amperes) Audible Strobe • Order Voltage andel Mounting At the 3 Audible Setting s @ 20, 24, 31 & 10.5,12 and 15.6 VDC Model Number' Code' (VDC) Candela Options' Strobe . 9 AS- 2415W -FR/FW 7404/7419 24 15 A,B,D,E,F,G,H,J,O,R,S,X Average Current - with Hi dBA Setting (99 dBA) • AS- 241575W -FR/FW 7405/7420 24 15/75 A,B,D,E,F,G,H,J,O,R,S,X Voltage AS -2415W AS- 241575W AS -2430W AS -2475W AS- 24110W AS- 2430W- FR/FW. 7436/7421 24 30 A,B,D,E,F,G,H,J,O,R,S,X 20.0 VDC 0.088 0.105 0.128 0.200 0.230 AS- 2475W - FR/FW ' =7407/7'4n 24 75 A,B,D,E,F,G,H,J,O,R,S,X 24.0 VDC 0.087 0.102 0.120 0.177 0.202 AS- 24110W -FR/FW 7408/7423 24 110 A,B,D,E,F,G,H,J,O,R,S,X 31.0 VDC 0.090 0.100 0.119 0.152 0.183 Voltage AS -1215W AS- 121575W AS -1215W -FR/FW 7409/7424 12 15 A,B,D,E,F,G,H,J,O,R,S,X 10.5 VDC 0.238 0.276 AS- 121575W -FR/FW 7410/7425 12 15/75 A,B,D,E,F,G,H,J,O,R,S,X 12.0 VDC 0.223 0.256 AH- 12 -R/W 7891/7894 12 - A,B,D,E,F,G,H,J,O,R,S,X 15.6 VDC 0.219 0.259 AH -24 -RAN 7892/7893 24 - A,B,D,E,F,G,H,J,O,R,S,X Voltage AS -2415C AS -2430C AS -2475C AS- 24100C AH- 12WP -R 7415 12 - K 20.0 0.105 0.147 0.291 0.323 AH- 24WP -R 7416 24 - K 24.0 0.102 0.135 0.250 0.277 • SPECIAL NOTE: AS Wall model numbers above reference both RED & WHITE 31.0 0.102 0.132 0.204 0.245 products; Example: AS- 2415W -FR = RED; Change FR to FW = WHITE Average Current - with Med dBA Setting (95 dBA) ORDER CODE: 7404= RED/7419 =WHITE Voltage AS -2415W AS- 241575W AS -2430W AS -2475W AS- 24110W CEILING MOUNT AUDIBLE STROBES 20.0 VDC 0.074 0.089 0.116 0.184 0.216 I Input 24.0 VDC 0.072 0.083 0.105 0.156 0.183 Order Voltage Strobe Mounting 31.0 VDC 0.067 0.077 0.092 0.130 0.158 • -- Model Number" Code (VDC) Candela Options' Voltage AS - 1215W AS 121575W AS- 2415C -FW 7411 24 15 A,B,D,E,F,G,H,J,R,S,V,X 10.5 VDC 0.185 0.223 AS-2430C-FW 7412 24 30 A,B,D,E,F,G,H,J,R,S,V,X 12.0 VDC 0.171 0.201 . AS- 2475C -FW 7413 24 15 A,B,D,E,F,G,H,J,R,S,V,X 15.6 VDC 0.152 0.182 AS-24100C-FW 7414 24 100 A,B,D,E,F,G,H,J,R,S,V,X Voltage AS -2415C AS -2430C AS -2475C AS- 24100C 20.0 0.091 0.134 0.273 0.308 - NOTES: 24.0 0.086 0.120 0.226 0.258 Refer code suffix: W = wall mount; WP = weather proof; 31.0 0.079 0.104 0.182 0.217 R = red plate; W at end = white; C = ceiling; F = fire lettering or call Customer - Service if other lettering is . required (Ex. Feugo). Average Current - with Low dBA Setting (90 dBA) • Example: AS 2415W - FR Flied AS2415C - FW -4-White Voltage AS -2415W AS- 241575W AS -2430W AS -2475W AS- 24110W � 20.0 VDC 0.070 0.084 0.111 0.178 0.210 Wall Tire Celi NIL- 24 VDC 0.064 0.077 0.098 0.149 0.177 '• Ceiling models available in red. Consult Wheelock Customer Service for delivery information ••' Refer to Data Sheet 057000 for additional momting information. 31.0 VDC 0.058 0.067 0.084 0.117 0.148 Voltage AS -1215W AS- 121575W A 10.5 VDC 0.171 0.217 Sync Module Input Current 12.0 VDC 0.156 0.194 Order Voltage @ 12 of Mounting 15.6 VDC 0.137 0.162 Model Number' Code (VDC) 24 VDC Options Voltage AS AS AS - 2475C AS 24100C SM- 12/24 -R . 6369' . 12' - .014- E,N. . 20.0 0.087 0.129 0.265 0.301 24 .025 E,N 24.0 0.077 0.113 0.219 0.252 31.0 0.069 0.096 0.168 0.207. DSM- 12/WR -R: . • ; 6374 12 .020 • . W - . - 24 .038 W • Average current per actual Wheelock Production Testing at 10.5,12, 15.6,20,24 & 31 VDC. For , rated average, peak and inrush current across the UL listed voltage range for both filtered DC and Note: SM Sync Modules are rated for 3.0 amperes at 12 or 24 VDC; DSM Dual Sync Modules are unfiltered VRMS. See Installation Instruction (P83509 for Series AS & P83519 for Series AH). rated for 3.0 amperes per circuit. The maximum number of interconnected DSM modules is twenty (20). Refer to Data Sheet 053000 and Installation Instruction (P83123 -SM & P83177 -DSM) for additional information. . dBA Ratings For Series AS /AH Audible AVERAGE CURRENT (Amperes) for Series AS & AH Audible Only Reverberent dBA Anrechoic dBA Voltage AH- 24 -R/W & WP Voltage AH-12-RAY & WP Description Volume per UL 464 10 fL @ 10 R Hi/Med/Lo HilMed/Lo 12 VDC & 24 VDC 12 VDC & 24 VDC 20.0 VDC .035/.020/.014 10.5 VDC .093/.037/.030 High 91 99 24.0 VDC .041/.024/.017 12.0 VDC .100/.043/.035 Continuous Med 88 95 31.0 VDC .053/.030/.021 15.6 VDC .128/.056/.040 Hom Low 82 90 CODE 3 High 85 99 • Hom Med 82 95 Low 75 90 Series AS /AH Quick Reference Guide 'Model# '•Model4 Wall Ceiling Non- Sync's w/ Strobe Color Color Model Number Mount Mount Sync SM or DSM Candela 24 VDC 12 VDC RED WHITE AS- 2415W -FR X X X 15 X X AS- 241575W -FR X X X 15/75 X X AS- 2430W -FR X X X 30 X X AS- 2475W -FR X X X 75 X X AS- 24110W -FR X X X 110 X X AS- 1215W -FR X X X 15 X X AS- 121575W -FR X X X 15/75 X X AS- 2415C -FW X X X 15 X X AS- 2430C -FW X X X 30 X X AS- 2475C -FW X X X 75 X X AS- 24100C -FW X X X 100 X X AH -12 -R X X X X X X AH -24 -R X X X X X X - AH- 12WP -R X X X X X X AH- 24WP -R X X X X X X • Model # Color is Red, can be ordered in White, see Specifications & Ordering Information for white order code. ▪ Model d Color is White, can be ordered in Red, call Customer Service for order code & Delivery. A WARNING: CONTACT WHEELOCK FOR "INSTALLATION INSTRUCTIONS" (P83509 Series AS, P83641 Series AH -WP & P83519 Series AH) AND "GENERAL INFORMAT SHEET (P82380) ON THESE PRODUCTS. THESE DOCUMENTS DO UNDERGO PERIODIC CHANGES. IT IS IMPORTANT THAT YOU HAVE CURRENT INFORMIAMIBE PRODUCTS. THESE MATERIALS CONTAIN IMPORTANT INFORMATION THAT SHOULD BE READ PRIOR TO SPECIFYING OR INSTALLING THESE PRODUCTS, INCLUDING: • TOTAL CURRENT REQUIRED BY ALL APPLIANCES CONNECTED TO SYSTEM PRIMARY AND SECONDARY POWER SOURCES. • FUSE RATINGS ON NOTIFICATION APPLIANCE CIRCUITS TO HANDLE PEAK CURRENTS FROM ALL APPLIANCES ON THOSE CIRCUITS. • COMPOSITE FLASH RATE FROM MULTIPLE STROBES WITHIN A PERSON'S FIELD OF VIEW. • THE VOLTAGE APPLIED TO THESE PRODUCTS MUST BE WITHIN THEIR RATED INPUT VOLTAGE RANGE. • INSTALLATION OF 110 CANDELA STROBE PRODUCTS IN SLEEPING AREAS. • INSTALLATION IN OFFICE AREAS AND OTHER SPECIFICATION AND INSTALLATION ISSUES. • USE SERIES AS /AH ONLY ON CIRCUITS WITH CONTINUOUSLY APPLIED OPERATING VOLTAGE. DO NOT USE SERIES AS ON CODED OR INTERRtl115IE9 9IRAIHICH THE APPLIED VOLTAGE IS CYCLED ON AND OFF AS THE STROBE MAY NOT FLASH. • FAILURE TO COMPLY WITH THE INSTALLATION INSTRUCTIONS OR GENERAL INFORMATION SHEETS COULD RESULT IN IMPROPER INSTALLATION, APPLICATION, AND OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE AND SERIOUS INJURY OR DEATH TO YOU AND /OR OTHERS. • CONDUCTOR SIZE (AWG), LENGTH AND AMPACITY SHOULD BE TAKEN INTO CONSIDERATION PRIOR TO DESIGN AND INSTALLATION OF THESE PBLARLY IN RETROFIT INSTALLATIONS. Wiring Diagrams (for all models) AS APPUANCE NON- SYNCHRONIZED AS APPLIANCE sm TO FROM + + NEXT APPLIANCE W S RM N IZED STROBE - . S STROBE PRECEDING OR END OF LINE MODULE STROBE STROBE • APPLIANCE — I, — RESISTOR OR FACP (EOLR) SINGLE CLASS F B" NAC A our ©. 1:31©2 MAR' CIRCUIT � c - - D • • willl WITH AUDIBLE a AUOIBII SILENCE MOW NAC FEATURE CIRCUIT FM' - AODIBLf SIGNAL • AS AND AH APPLIANCES SYNCHRONIZED WITH DSM MODULE SINGLE "A" NAC AS AND AH APPLIANCES ® er" 0 0 0 CIRCUIT WITHOUT AUDIBLE SILENCE FEATURE SYNCHRONIZED WITH MULTIPLE DSM DSM MODULES e • _ e SYNC + e SYNC - 0 +OUT1 ' + IN I 11111 ®+ n el O =CM +AUDIBLE I - : _AUDIBE MINU _ +IN 2 I �m�®• 11.11 AUDIBLE 0 STBC DSM INTERCONNECTING WIRING SHOWN. MAXIMUM a TWENTY (20) -ieter to JIVI /UJM uald Street J.3000 a11U IrISldllatuurI IrISuut uu IS IrtSd IL3-JM tk 1 1 1 /-UJM). • Value determined by FACP NAC circuits. Note: Series AS /AH must be set on Code 3 horn tone to achieve synchronized temporal (code 3) tone and connected to the SM or DSM Sync Module. Wheelock - products must be used within their published specifications and must be PROPERLY specified, applied, installed, operated, maintained and operationally tested in accordance with their installation instructions at the time of installation gat least twice a year or more often and in accordance with local, state and federal codes, regulations and laws. Specification, apptioa, `°--- installation, operation, maintenance and testing must be performed by qualified personnel for proper operation in accordancetivi all of the latest National Fire Protection Association (NFPA), Underwriters' Laboratories (UL), National Electrical Code (NEC), Occupational Safety and Health Administration (OSHA), local, state, county, province, district, federal and other applicable !Wing and fire standards, guidelines, regulations, laws and codes including, but not limited to, all appendices and amendments andath requirements of the local authority having jurisdiction (AHJ). Architects and Engineers Specifications notification appliances shall be Wheelock's Patented Series AS Audible Strobe and Series AH Audible appliances; and whE n I The synchronization is required the companion Series SM and DSM Sync Module(s), or approved equals. Series AS appliances Seri( s . nd SM and DSM Sync Module(s) shall be listed under UL Standard 1971 (Emergency Devices for the Hearing Impaired for Indoor ,:ire Protection Service). Series AH Audible shall be UL listed under Standard 464 (Fire Protective Signaling). Series AS, AH, SM and DSM shall be certified to meet FCC part 15, Class B. The appliances shall be designed for 2 -wire operation and shall provide either a continuous or temporal (Code 3) tone when ctarat voltage from a Notification Appliance Circuit (NAC) of the Fire Alarm Control Panel (FACP) is applied or synchronized temporal (Code 3) tone and synchronized strobe when used in conjunction with the Series SM or DSM Sync Module(s). Series AS shall be designed so that the audible signal may be silenced while maintaining strobe activation (when used with tie Series SM or DSM Sync Module(s)). The Series SM and DSM Sync Module(s) shall incorporate two inputs from the Notificati )n Appliance Circuits (NAC) for power connection from the Fire Alarm Control Panel; one for the strobe circuit (NAC) and one flee t audible circuit (NAC). A single 2 -wire output shall control both the audible and visual appliances. Upon activation of the audible . silence function of the Fire Alarm Control Panel, the audible signal shall be silenced while maintaining strobe activation. Sound output at 10 feet shall be field selectable for 90, 95, or 99 dBA anechoic for both continuous and temporal (Code 3) tones Series AS shall provide listed strobe intensities of 15, 15/75, 30, 75, and 110 candela for wall mount and /or 15, 30, 75 anlD 10 . candela for ceiling mount applications, with a flash rate of one flash per second minimum across the Listed voltage range. T le strobe appliance shall incorporate a Xenon flashtube enclosed in a rugged Lexan lens. The maximum allowable average current at 24 VDC for wall mount shall be 87 mA @ 15 cd, 102 mA CO 15/75 cd, 120 mA @ 30 cd, 177 mA @ 75 cd and 202 mA CO 110 cd. The maximum allowable average current at 24 VDC for ceiling mount shall be 102 mA CO 15 cd, 135 mA @ 30 cd, 250 mA 75 cd and 277 mA @ 100 cd. All appliances shall incorporate a zero inrush circuit design. The strobe shall have a horizontalr}da The Sync Module shall be designed and available in two versions; the SM 12/24 for control of a single Class B NAC circuit; E nd a dual output version, the DSM -12/24 for control of either a single Class A or two Class B NAC circuits. The DSM shall prov de the additional capability of "daisy- chaining ", that is, the ability to interconnect multiple DSM's for synchronous audible and strobe operation on multiple NAC circuits. DSM -12/24 Interconnection capability shall be for a maximum of 20 modules (40 Cla s "B" NAC circuits or 20 Class "A" NAC circuits). Rated average current requirement for the SM 12/24 shall be .014 amperes @ 12 VDC and .025 amperes © 24 VDC; the DSM 12/24 shall be .020 amperes © 12 VDC and .038 amperes © 24 VDC. The SM Sync Module shall be capable of handling a 3 ampere load at 12 or 24 VDC; the DSM Sync Modules shall be capable of handling a load of 3 amperes percircuihn the Class "B" mode and 3 amperewermodu /e in the Class "A" mode at 12 or 24 VDC. Series SM or DSM Sync Module(s) and Series AS Audible Strobes shall be designees a system for continuous activation of the strobes should the Sync Control Module contacts fail in the passive state (i.e., contacts remain closed). In this default modbp strobes shall revert to a non - synchronized default flash rate. `" Series AS /AH appliances shall be designed for operation at 12 VDC or 24 VDC, over their respective listed voltage ranges of510. to 15.6 VDC; and 20.0 to 31.0 VDC. The units shall be designed for operation on filtered DC, or unfiltered VRMS. Rated average current for Series AS shall depend upon voltage and strobe intensity; the current shall be as low as .058 amperes fdr 2 VDC versions and .145 amperes for 12 VDC versions. Rated average current for Series AH (volume set at high dB output) shall be .041 amperes for 24 VDC versions and .113 amperes for 12 VDC versions. . All versions shall be polarized for DC supervision and shall incorporate screw terminals for in /out field wiring of #18 to PANG wire size. Series AS /AH shall incorporate a unique Patented Universal Mounting Plate which shall allow mounting to single -gang, doubl )- . gang, 4" square, 100 mm European backboxes or Wheelock's SHBB surface backbox. No additional trim plate shall be required for flush mounting. If required an NATP (Notification Appliance Trim Plate) shall be provided. Dimensions for the Series AS /AH shall be 4 and 5/8 inches square by 1 arldinches deep. Due to continuous development of our products, specifications and offerings are subject to change without notice in accordithcWI eelock, Inc. standard terms and conditions: 3 YEAR WARRANTY Distributed By: NATIONAL SALES OFFICE 1 -800- 631 -2148 Canada 800- 397 -5777 P P - NA E -mail: Info @wheelockinc.com r M � .' http: / /www.wheelockinc.com Member • . WHEELOCK, • 273 BRANCHPORT AVENUE' LONG BRANCH, N.J. 077401 732 - 222 -6880 ■ FAX: 732 - 222 -8707 S8100 REV. 5/98 w heel o ck A INC. FIRE ALARM SYSTEMS SERIES RS STROBES AND SERIES Description RSS NON - SYNC /SYNC STROBES Wheelock's patented Series RS Strobes and Series RSS Non - i —�-- Sync /Sync Strobes have Lower Current Draw and the Series ► ' i ar.3( FIRE RSS has ZERO Inrush while maintaining their outstanding performance, reliability and cost - effectiveness in meeting or ^' exceeding the latest requirements of NFPA 72 (National Fire 3' ri gtr Alarm Code - 1996), ANSI 117.1 (American National Standard for Accessible and Usable Building and Facilities), and UL Standard " v1 1971 (Signaling devices for the Hearing Impaired). RS /RSS ;5. 'P • FIRE . Strobe Appliances, when properly specified and installed in accordance with NFPA /ANSI Standards, can provide the Series RS /RSS Series RS/RSS Equivalent Facilitation allowed under ADA Accessibility Strobe Mounting Plate Wall Cover Plate Guidelines (ADAAG General Section 2.2) by meeting or exceeding the illumination which results from ADA's strobe intensity guidelines of 75 candela at 50 feet. This is an illumination of 0.030 lumens per square foot. Wheelock's Series RS Strobes are available with 15 and 15/75 candela intensities forWall mount only and non -sync applications. - The Series RSS Strobes include Non -Sync and Sync in ONE appliance. The SM or DSM Sync Module must be used to achieve k Sychronization of the strobe. Synchronized strobes can eliminate possible restrictions on the number of strobes in the field of view. Wheelock's synchronized strobes offer an easy way NATP Wall Strobe to comply with ADA recommendations concerning photosensitive epilepsy. The strobe options for the Series RSS Features are 15, 15/75, 30, 75 and 110 candela intensities foWall mount and 15, 30, 75 and 100 candela intensities foCeiling mount Series RS /RSS Strobes: applications. • Approvals Include: Underwriters Laboratories UL 1971, FCC All strobes use a Xenon flashtube enclosed in a rugged Lexan® Part 15, European Community (CE), New York City (MEA), provide maximum reliability for effective visual signaling. (FM). Pending: ing: Fire Marshal (CSFM), and Factory Mutual lens to P y g g• (FM). Pending: Chicago (BFP). Wheelock's Series RS /RSS Strobes employ an integralStrobe • ADA/NFPA/ANSI compliant. Meets OSHA 29, Part 1910.165. Mounting Plate (patent pending) that makes it easy to mount to • LOW CURRENT. a variety of backboxes. The strobes can be mounted to sing /e- • Strobe Mounting Plate (patent pending) for single gang, gang, doub /e -gang, 4° square, 100 mm European backboxes or double gang, 4" square, or 100 mm European backboxes. • the SHBB surface backbox. If the flush backbox has side or top Wheelock's SHBB shallow backbox is used for surface space between it and the finished wall, the NEW NATP mounting. • Low current draw with temperature compensation to reduce (Notification Appliance Trim Plate) may be used. It provides an additional .65" of trim for the appliance. An attractive cover plate • Power and wiring costs. Polarizeed d 1 12 2 and nd 24 VDC C models with wide listed voltage is provided for a clean, finished appearance on all models. ranges using filtered DC or unfiltered VRMS input voltage. • Fast installation with IN /OUT screw terminals using #12 to /18 AWG wires. Series RS: • 24 Volt only. • Wall mount only • Available only in 15 and 15/75 candela intensity. • Non -Sync application only WM3T Series RSS Strobes: Since the inception of UL 1971 strobes cannot be Listed for outdoor USE, • Both Non -Sync and Synchronized in ONE appliance. To Wheelock offers WM3T strobes for outdoor installations requiring achieve Synchronization aSM or DSM Sync Module must be weatherproof appliances and private mode operation where UL 1971 used. strobes are not required. They are UL 1638 Listed at 117cd and ar • ZERO INRUSH. designed for surface mounting indoors or outdoors. • 12 or 24 volt models. "NOT TO BE USED AS AN INDOOR VISUAL EVACUATION SIGNAL • Wall mount (RSS) available in 15, 15/75, 30, 75 and 110 OR FOR THE HEARING IMPAIRED." candela intensity. ONLY 88 MILLIAMPS • 15/75 candela low current draw wall mounted strobes are 20 VDC listed at 15 candela under UL 1971 and meet 75 candela intensity on axis for ADA guidelines. WM3T - Ul. 1638 LISTED • Ceiling mount (RSS) available In 15, 30, 75 and 100 candela intensity. • Refer to Spec Sheet #S1100 for Series RSSP retrofit plates. Copyright 1998 Wheelock, Inc. All rights reserved. • NOTE: All CAUTIONS and WARNINGS are identified by the syrtgol4ll warnings are printed in bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR PWPUI PRODUCT. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS AND WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTNJ 1111OOR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND /OR OTHERS eneraI Notes: • Strobes are designed to flash at 1 flash per second minimum from 20 -31 VDC (for 24 VDC models) or 10.5 -15.6 VDC (for 12 VDC models). Note that NFPA -72 (1996) specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second. • All candela ratings represent minimum effective Strobe intensity based on UL 1971. • Series RS /RSS Strobe products are Listed under UL 1971 for indoor use with a temperature range of 32° F to 120° F (0° C to 49° C) and maximum humidity of 85 %. • The WM3T strobe is Listed under UL 1638 for outdoor use with a temperature range of -31 °F to 150 °F ( -35 °C to 66 °C) maximum humidity of 95 %. Specifications and Ordering Information • Average" Average" Input Current Input Current Order Voltage Strobe (AMPS) Mounting Order Voltage Strobe (AMPS) Mounting Model Number Code (VDC) Candela @ 24 VDC Options *" _ Model Number Code (VDC) Candela 24 VDC Options *" WALL MOUNT STROBES - SERIES RS /RSS SYNC MODULE RS- 2415W -FR 7465 24 15 .050 B,D,E,F,G,H,J,N,O,R,X SM- 12/24 -R 6369 12 - .014 E,N RS- 241575W -FR 7466 24 15/75 .065 B,D,E,F,G,H,J,N,O,R,X 24 - .025 E,N DSM- 12/24 -R 6374 12 - .020 W RSS- 2415W -FR 7470 24 15 .050 B,D,E,F,G,H,J,N,O,R,X 24 - _ .038 W RSS- 241575W -FR 7471 24 15/75 .065 B,D,E,F,G,H,J,N,O,R,X RSS- 2430W -FR 7472 24 30 .081 B,D,E,F,G,H,J,N,O,R,X "AVERAGE CURRENT SERIES RSS WALL MOUNT APPUANCES (24V) RSS- 2475W -FR 7473 24 75 .133 B,D,E,F,G,H,J,N,O,R,X Voltage RSS -2415W RSS- 241575W RSS -2430W RSS -2475W RSS- 24110W RSS- 24110W -FR 7474 24 110 .161 B,D,E,F,G,H,J,N,O,R,X 20VDC 0.060 0.076 0.095 0.157 0.199 RSS- 2415W -FW 7787 24 15 .050 B,D,E,F,G,H,J,N,O,R,X 24VDC 0.050 0.065 0.081 0.133 0.161 RSS- 241575W -FW 7788 24 15/75 .065 B,D,E,F,G,H,J,N,O,R,X 31VDC 0.043 0.052 0.066 0.108 0.131 • • RSS- 2430W -FW 7788. 24 30 .081 B,D,E,F,G,H,J,N,O,R,X RSS - 2475W - FW 779 75 .133 B,D,E,F,G,H.J,N,O,R,X "AVERAGE CURRENT RSS WALL MOUNT APPUANCES (12V) RSS- 24110W -FW 7791 24 110 .161 B,D,E,F,G,H,J,N,O,R,X Voltage RSS -1215W RSS- 121575W RSS- 1215W -FR 7475 12 15 .126 B,D,E,F,G,H,J,N,O,R,X 10.5VDC 0.148 0.189 RSS- 121575W -FR 7476 12 15/75 .161 B,D,E,F,G,H,J,N,O,R,X 12VDC 0.126 0.161 • RSS- 1215W -FW 7467 12 15 .126 B,D,E,F,G,H,J,N,O,R,X 15.6VDC 0.102 0.130 RSS- 121575W -FW 7468 1 12 1 15/75 .161 B,D,E,F,G,H,J,N,O,R,X CEILING MOUNT STROBES - SERIES RSS "AVERAGE CURRENT RSS CEILING MOUNT (24V) RSS- 2415C -FW 7482 24 15 .067 B,D,E,F,G,H,J,N,X Voltage RSS -2415C RSS-2430C RSS -2475C RSS- 24100C RSS- 2430C -FW 7483 24 30 .102 B,D,E,F,G,H,J,N,X 20VDC 0.078 0.120 0.247 0.285 RSS - 2475C -FW 1484 24 75 .204 B,D,E,F,G,H,J,N,X 24VDC 0.067 0.102 0.204 0.238 RSS- 24100C -FW 7485 24 100 .238 B,D,E,F,G,H,J,N,X 31VDC 0.055 0.085 0.157 0.190 SM Sync Module is rated for 3.0 amperes at 12 or 24 VDC; DSM Sync Module is rated fa 3.0 SPECIAL NOTE: amperes per circuit. The maximum number of interconnected DSM modules is twenty (20). 12 VOLT WALL MODELS (RSS - 1215W AND RSS 121575W) WILL BE (Refer to Data Sheet S3000 or installation instructions (P83123 for SM and P83177 for DSM).) Use AVAILABLE JANUARY, 1998. FOR APPLICATIONS REQUIRING THESE with Series RSS appliances for synchronization. APPLIANCES PRIOR TO THIS DATE, REFER TO DATA SHEET #SO400 OR CALL • Series RS -Wall. RSS -Wall and RSS - Ceiling are available in either Red white. Please contact CUSTOMER SERVICE FOR ASSISTANCE. a w Customer Service for order codes (if not stated above) and delivery information. Model code suffix: W = wall or C = ceiling; F = fire lettering or call Customer Service if other lettering is required (Ex.: Feugo). R at end = red plate; W al end = white plate; Example: RSS- 2415W -FR tRed R RSS- 2415W- FW ro1e RSS2415C -FW White Wall ire wax Jf Fire CRiiirNj ire " Average current per actual Wheelock Production Testing @ 10.5, 12, 15.6, 20, 24 and 31 VDC. For rated average and peak current across the UL Listed voltage range for both filtered DC and full -wave rectified (FWR), see the installation instructions (P83500 for wall mount and P83501 for ceiling mount). • Refer to Data Sheet 57000 for mounting options. I 117 cd STROBE INDOOR OR OUTDOOR (must use WBB box for outdoor) Input Average Order Voltage Strobe Current Model Number Code (VDC) Candela (AMPS) Mounting Options • WM3T -24 -VFR 4911 24 117 .088 J,K Note: WM3T -24 -VFR - UL 1638 only. Refer to installation instructions (P82037). SERIES RS and SERIES RSS QUICK REFERENCE GUIDE 'Model # "Model # Wall Ceiling Non- Sync's w/ Strobe Color Color Model Number Mount Mount Sync SM or DSM Candela 24 VDC 12 VDC RED WHITE RS- 2415W -FR X X 15 X X RS- 241575W -FR X X 15/75 X X RSS- 2415W -FR X X X 15 X X RSS- 241575W -FR X X X 15/75 X X RSS- 2430W -FR X X X 30 X X RSS- 2475W -FR X X X 75 X X RSS- 24110W -FR X X X 110 X _ X RSS- 1215W -FR X X X 15 X X RSS- 121575W -FR X X X 15/75 X X RSS- 2415C -FW X X X 15 X X RSS- 2430C -FW X X X 30 X X • RSS- 2475C -FW X X X 75 X X RSS- 24100 -FW X X X 100 X X • Model 1 Color is Red, can be ordered in White, see Specifications & Ordering Information for white order code. •' Model 1 Color is White, can be ordered in Red, call Customer Service for order code & Delivery. A WARNING: CONTACT WHEELOCK FOR THE CURRENT "INSTALLATION INSTRUCTIONS" (P83500 FOR WALL MOUNT AND P83501 FOR CEILING MOUW EAIBAL INFORMATION" SHEET (P82380) ON THESE PRODUCTS. THESE DOCUMENTS DO UNDERGO PERIODIC CHANGES. IT IS IMPORTANT THAT YOU HAVE CUERIBNATION ON THESE PRODUCTS. THESE MATERIALS CONTAIN IMPORTANT INFORMATION THAT SHOULD BE READ PRIOR TO SPECIFYING OR INSTALLING THESE PRODUCTS, INCLUDING: • TOTAL CURRENT REQUIRED BY ALL APPLIANCES CONNECTED TO SYSTEM SECONDARY POWER SOURCES. • FUSE RATINGS ON NOTIFICATION APPLIANCE CIRCUITS TO HANDLE PEAK CURRENTS FROM ALL APPUANCES ON THOSE CIRCUITS. • COMPOSITE FLASH RATE FROM MULTIPLE STROBES WITHIN A PERSON'S FIELD OF VIEW. • THE VOLTAGE APPLIED TO THESE PRODUCTS MUST BE WITHIN THEIR RATED INPUT VOLTAGE RANGE. • INSTALLATION OF 110 CANDELA STROBE PRODUCTS IN SLEEPING AREAS. • INSTALLATION IN OFFICE AREAS AND OTHER SPECIFICATION AND INSTALLATION ISSUES. • USE STROBES ONLY ON CIRCUITS WITH CONTINUOUSLY APPLIED OPERATING VOLTAGE. DO NOT USE STROBE ON CODED OR INTERRUPTED CIRRIII@IIIIHE APPLIED VOLTAGE IS CYCLED ON AND OFF AS THE STROBE MAY NOT FLASH. • FAILURE TO COMPLY WITH THE INSTALLATION INSTRUCTIONS OR GENERAL INFORMATION SHEETS COULD RESULT IN IMPROPER INSTALLATIOBPAELIAND /OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE AND SERIOUS INJURY OR DEATH TO YOU AND /OR • OTHERS. .i • CONDUCTOR SIZE (AWG), LENGTH AND CAPACITY SHOULD BE TAKEN INTO CONSIDERATION PRIOR TO DESIGN AND INSTALLATION OF THESE PBLARLY • -- • IN RETROFIT INSTALLATIONS. Wiring Diagrams (For All Models) RSS APPLIANCE NON- SYNCHRONIZED RSS APPLIANCE SYNCHRONIZED - -- WITH SM ..,. - _ - 10 NEXT APPLIANCE MODULE SINGLE e �j( OR END -OF -LINE CLASS "B" NAC FROM PRECEDING ` RESISTOR(EOLR) CIRCUIT WITH L APPLIANCE OR FACP AUDIBLE C - SILENCE 111;:"- FEATURE SCI ❑ (3 ❑ Ni1 4. R RSS APPUANCES SYNCHRONIZED WITH DSM MODULE DUAL CLASS "A" NAC RSS APPLIANCE CIRCUIT WITH NO AUDIBLE SILENCE FEATURE SYNCHRONIZED -� DSM WITH MULTIPLE e SYNC • DSM MODULE _ e SYNC - lts1 =R Ir AUDIBLE C : •• IC. U TN 1 11 TPI TUC I BUR ".• C G C : MINUS 2 1211E0 =. .. :. IN 2 0 T.. AUDIBLE NAC s • OUT 1 0 CIRCUIT RETURN WTERCONNECTING WIRING SHOWN. MAXIMUM Of TWENTY (20) For detail using SM or DSM Sync Module refer to Data Sheet S3000 or installation instructions (P83123 for SM and P83177 for DSM). • Value determined by FACP NAC Circuit(s). Wheelock products must be used within their published specifications and must be PROPERLY specified, applied, installed, operated, maintained and operationally tested in accordance with their installation instructions at the time of installation and at least twice a year or more often and in accordance with local, state and federal codes, regulations and laws. Specification, application, installation, operation, maintenance and testing must be performed by qualified personnel for proper operation in accordance with all of the latest . National Fire Protection Association (NFPA), Underwriters' Laboratories (UL), National Electrical Code (NEC), Occupational Safety and Health Administration (OSHA), local, state, county, province, district, federal and other applicable building and fire standards, guidelines, regulations, laws and codes including, but not limited to, all appendices and amendments and the requirements of the local authority having jurisdiction (AHJ). Architects and Engineers Specifications The visual notification appliances shall be Wheelock Series RS or RSS Strobe Appliances, or approved equals. Series RS /RE S shall meet and be Listed under UL Standard 1971 (Emergency Devices for the Hearing Impaired for indoor fire protection service). 1 strobes shall be listed for indoor use only. All strobes shall be certified to meet FCC Part 15 Class B. The strobe applies shall produce a flash rate of one (1) flash per second minimum over the Listed Voltage range of 20 to 31 VDC for 24 volt models and 10.5 to 15.6 VDC for 12 volt models. All inputs shall be polarized for compatibility with standard reverse polarity supeioh of circuit wiring by a Fire Alarm Control Panel (FACP). All visual appliances shall incorporate a Xenon flashtube enclosed in a rugged Lexan lens. The Series RS and RSS Strobes shall be the Low Current Design and the RSS shall have Zero Inrush. The strobe intensity shall be rated per UL 1971 for 15, 15/75, 30, 75, and 110 candela for wall mount and 15, 30, 75 and 100 candela for ceiling mount applications for the Series RSS and 15 end 15/75 candela wall mount for Series RS public mode installations. The 15/75 candela strobe shall be specified when 15 candela UL 1971 listing with 75 candela intensity on -axis is required (e.g., ADAcompliance). Series RSS appliances shall incorporateciitry for synchronized strobe flash and shall be designed for compatibility with Wheelock Series SM and DSM Sync Modules. The strobes • shall not drift out of synchronization at any time during operation. If the sync module fails to operate (i.e., contacts remailesed), the strobes shall revert to a non - synchronized flash rate. The visual appliances shall be designed for indoor surface or flush mounting. Series RS and RSS models shall employ a pate nt pending Strobe Mounting Plate that shall allow mounting to single -gang, double -gang, 4 inch square, 100mm European tyr e backboxes, or the SHBB Surface Backbox. If required an NATP (Notification Appliance Trim Plate) shall be provided. An attaching cover plate shall be provided to give the appliance an attractive appearance. The aesthetic appearance shall not have any mounting holes or screw heads visible when the installation is completed. For outdoor installations, the strobe appliance shall be the Wheelock WM3T. The WM3T shall meet and be Listed under UL1638 (Private Mode Emergency and Utility Signaling). "NOT TO BE USED AS AN INDOOR VISUAL EVACUATION SIGNAL OR F04 THE HEARING IMPAIRED." The WM3T shall be mounted to a weather resistant backbox: either the Wheelock WBB box or approved equal when mounted outdoors. The WM3T strobes shall produce a flash rate of one (1) flash per second minimum over the List ?d Voltage range of 20 -31 VDC for 24 volt models. The strobe intensity shall be rated at 117 candela. Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Wheelock. Inc. standard terms and conditions. • \4i 3 YEAR WARRANTY Distributed By: NATIONAL SALES OFFICE 1- 800 -631 -2148 Canada 800 - 397 -5777 N3V1A E - mail: Info@wheelockinc.com http: / /www.wheelockinc.com MEMBER WHEELOCK, INC. • 273 BRANCHPORT AVENUE • LONG BRANCH, N.J. 07740 • 732 - 222 -6880 ■ FAX: 732 - 222 -8707 SO410 REV. 3/98