Loading...
Report (688) Main Office Branch Office P.O. Box 23814 4060 Hudson Ave., NE Tigard, Oregon 97281 Salem, OR 97301 Carlson Testing Inc. Phone (503) 6843460 Phone (503) 589 -1252 b� FAX (503) 6840954 FAX (503) 589 -1309 /2)9- 0o 23 c August 10, 1999 99- 2536A. CTI Permit No. BUP1999 -00234 SHOP INSPECTION REPORT @ Howser Steel DATES COVERED: August 2-4, 1999 PROJECT: Tigard Corporate Center — Building B ADDRESS: 12259 SW 69 Tigard, OR INSPECTOR: J. Svacek, COP#649, WABOSVA520867 08 -02, 03, and 04 -99: CTI representative was at the shop of Howser Steel for continuous inspection. Continuous inspection provided for welding of #6 rebar to embeds listed. Preheat for table 4 AWS D1.4 is verified. Welds are multi -pass fillets, welded by certified welder per WPS. Mark number 1A (48), 1B (16), and 1C (16). Rebar is verified as A706. Welds are of acceptable appearance. Welds, weld procedures and welder qualifications were reviewed. Our reports pertain to the material tested /inspected only. Information contained herein is not to be reproduced, except in full, without prior authorization from this office. If there are any further questions regarding this matter, please do not hesitate to contact this office. Respectfully submitted, ARLSON TESTIN NC. 44/44 1 4 1411/31PUIT ,i Douglas W. Leach President JS /Ijm cc: Specht Development, Inc. — Bob Burns City of Tigard Building Department Baugh Construction Co. LRS Architects VLMK