Report (688) Main Office Branch Office
P.O. Box 23814 4060 Hudson Ave., NE
Tigard, Oregon 97281 Salem, OR 97301
Carlson Testing Inc. Phone (503) 6843460 Phone (503) 589 -1252
b� FAX (503) 6840954 FAX (503) 589 -1309
/2)9- 0o 23 c
August 10, 1999
99- 2536A. CTI
Permit No. BUP1999 -00234
SHOP INSPECTION REPORT @ Howser Steel
DATES COVERED: August 2-4, 1999
PROJECT: Tigard Corporate Center — Building B
ADDRESS: 12259 SW 69 Tigard, OR
INSPECTOR: J. Svacek, COP#649, WABOSVA520867
08 -02, 03, and 04 -99: CTI representative was at the shop of Howser Steel for continuous inspection.
Continuous inspection provided for welding of #6 rebar to embeds listed. Preheat for table 4 AWS D1.4 is
verified. Welds are multi -pass fillets, welded by certified welder per WPS. Mark number 1A (48), 1B (16), and
1C (16). Rebar is verified as A706. Welds are of acceptable appearance. Welds, weld procedures and
welder qualifications were reviewed.
Our reports pertain to the material tested /inspected only. Information contained herein is not to be reproduced,
except in full, without prior authorization from this office.
If there are any further questions regarding this matter, please do not hesitate to contact this office.
Respectfully submitted,