Report (728) • Construction Inspection & Related Tests Carlson Testing, Inc. Geotechnical Consulting 1 rN...C EIVED , X J. C°NC:K(_ - Tf_: REPORT OF F TEST SPECIMENS JUL 1 t 2000 P.O. Box 23814 A`'lr C1. 72/C1231./C39/C3 r Tigard, Oregon 97281 " "° `" ,h 503 684 -3460 Test Methods: E Y : -� _ P one A # 684-0954 06/29 00 T0004403 "' -00 2 Date Molded: 20 Job No. P mit No: Client: SF'ECHT DEVELOPMENT INC - BOB BURNS Project: TIGARD CORPORATE CENTER PARKING STRUCTURE Address: 12125 SW 69TH TIGARD OR Contractor: X Sub Contractor: Concrete supplier: ROSS ISLAND SAND & GRAVEL Truck No. 20 / T187925 Ticket No. Cast By: C. STASCH Cu. Yds. 1) OF 1.61 Load No SUNNY 79 — .Tern.9 . High: -_ — Tema Low: Weather: --- �- � --- - -- - - POST TENSION SLAB POUR #1 BETWEEN 3.5 TO 9, A TO D LINE Location of Placement: 10 :t0 81 Test Time: Concrete Temp: 5000 28 4 1/2" I Strength Requirement: PSI @ days Slump Cement Type 5031E 3/4" Mix NoJNo. Sacks Air Content Max. Aggregate WATER REDUCER POLYHEED Admix. Amount: Brand _ Admix. Amount: Brand: Set Test@ Register Date Date Total Area Unit Report Tested rea No. Days Number Rec'd Test Load PSI No. By IV 7 3104 06/30 07/06 128,310 28.26 4540 MS 28 3104 06/30 07/27 28 3104 06/30 07/27 HOLD 3104 06/30 Rer ritLD CURE CYLINDERS ARE ON A SEPERATE SHEET. ,--- .-• HEET . • _ cc : (_RS ARCHITECTS CITY OF TIGARD _ - / VLMK /: / Reviewed by: . . . .. • Carlson Testing, Inc. Construction Inspection & Related Tests Geotechnical Consulting REPORT OF X l '` t- UN�RE (L_: TEST SPECIMENS R.F-7-,?---33-` " -WED P.O. Box 23814 /V;TM C1.72/C1231/C39/C31./C1064/C143 . JUL 1 1 2000 Tigard, Oregon 97281 Test Methods: Phone (503) 684 -3460 FAX # 684 -0954 Date Molded: 06/29 20 00 Job No. T00044 ;Y: EIUP2 00 - 00012 Client: SPECHT DEVELOPMENT INC - BOB BURNS Project: TIGARD CORPORATE CENTER PARKING STRUCTURE Address: 12125 SW 69TH TIGARD OR Contractor: X Sub Contractor: ROSS ISLAND SAND & GRAVEL 208 T187919 Concrete Supplier: Truck No. Ticket No. Cast By: C . S T A SC H Cu. Yds. 1 1 OF 117 Load No. 1 SUNNY 79 Weather: . Temp. High: Temp. Low: POST TENSION SLAB POUR #1 BETWEEN 3.5 10 9, A TO D LINE Location of Placement: 9 : 4', 82 Test Time: Concrete Temp: 5000 28 4 3/4" I Strength Requirement: PSI @ days Slump Cement Type 5031B 3/4" Mix No /No. Sacks Air Content . Max. Aggregate WATER REDUCER POLYHEED Admix. Amount: Brand Admix. Amount: Brand: Set Test@ Register Date Date Total Area Unit Report Tested r ea No. Days Number Rec'd Test Load PSI No. By III 7 3106 06/30 07/06 124,510 2 8.26 4410 MS 28 3106 06/30 07/27 , 2.8 3106 06/30 07/27 56 3106 06/30 08/24 i Rerrr io:LD CURE CYLINDERS ARE ON A SEPERATE SHEET . ! /"'" c:c:: LRS ARCHITE:CTs CITY OF TIGARD ! `'- VLMK r` Reviewed by: • Carlson Testing, Inc. Construction Inspection & Related Tests Geotechnical Consulting REPORT OF TEST SPECIMENS P.O. Box 23814 /1 C172/C1231/C39/C31%(:.1064/C143 JUL 11 2000 Tigard, Oregon 97281 Test Methods: Phone (503) 684 -3460 FAX # 684 -0954 Date Molded: 06/29 20 00 Job No. T0004403 Perm utF'�C)( - 0(1)12 Client: SPECHT DEVELOPMENT INC - BOB BURNS Project: TIGARD CORPORATE CENTER PARKING STRUCTURE Address: 12125 SW 69TH TIGARD OR Contractor: X Sub Contractor: Concrete supplier: ROSS ISLAND SAND & GRAVEL Truck No. 201 T187913 Ticket No. Cast By: C C . STASCH Cu. Yds. 1) OF 66 Load Nob SUNNY 75 Weather: . . Temp. High: Temp. Low: POST TENSION SLAB POUR #1 BETWEEN 3.5 T0 9, A TO D LINE Location of Placement: 8: ?,0 75 Test Time: Concrete Temp: 5000 28 5 1/4" I Strength Requirement: PSI @ days Slump Cement Type 5031B 3/4" Mix NoJNo. Sacks Air Content Max. Aggregate WATER REDUCER POLYHEED Admix. Amount: Brand: _ Admix. Amount: Brand: Set Test@ Register Date Date Total Area Unit Report Tested rea No. Days Number Rec'd Test Load PSI No. By II 7 3108 06/30 07/06 125,230 28.26 4430 MS 28 3108 06/30 07/27 28 3108 06/30 07/27 56 3108 06/30 08/24 RerrI iLLD CURE CYLINDERS ARE ON A SEPERATE SHEET /` =' cc : LRS ARCHITECTS --��� CITY OF TIGARD ;' VLMK Reviewed by: . .. • Construction Inspection & Related Tests Carlson Testing, Inc. Geotechnical Consulting • REPORT OF6X 1..' C°NCRL T L . TEST SPECIMENS ° 7 .7 � 7- � T V �iJ P.O. Box 23814 AS.'TM t 172 /C 1231/C39/C31 Tigard, Oregon 97281 Test Methods: JUI 1_ Phone (503) 684 - 3460 FAX # 684 -0954 06/29 2 p 00 Job No. T0004403 Ir ' . No BUP2000 00012 Date Molded: . Client: SL'ECHT DEVELOPMENT INC - HOB BURNS Project: TIGARD CORPORATE CENTER PARKING STRUCTURE 12125 SW 69TH TIGARD OR Address: Contractor: x Sub Contractor: Concrete Supplier: ROSS ISLAND SAND & GRAVEL Truck No. 208 T187889 Ticket No. Cast By: C. S T A S C H Cu. Yds. 11 OF 22 Load N SUNNY 70 Weather: Temp. High: Temp. Low: POST TENSION SLAB POUR #1 BETWEEN 3.5 10 9, A TO D LINE Location of Placement: 7 : 45 78 Test Time: Concrete Temp: 5000 28 6 1/2" I Strength Requirement: PSI @ days Slump Cement Type 5031E 3/4" Mix NoJNo. Sacks Air Content Max. Aggregate WATER REDUCER POLYHEED Admix. Amount: Brand _ Admix. Amount: Brand: Set Test@ Register Date Date Total Area Unit Report Tested No. Days Number Rec'd Test Load PSI No. By 1 7 3110 06/30 07/06 126,920 28.26 4490 MS 28 3110 06/30 07/27 28 3110 06/30 07/27 56 3110 06/30 08/24 ■ ■ RerrerfLD CURE CYLINDERS ARE ON A SEPERATE SHEET /' • cc.: L_RS ARCHITECTS -- -- - - -- CITY OF TIGARD VI_MK ,. / % _. Y M A n!.rrr Reviewed by: • Carlson Testing, Construction Inspection & Related Tests ng, Inc. Geotechnical Consulting f,X l :? C:ONCRL rl: JUL 1 1 REPORT OF TEST SPECIMENS ZQQO P.O. Box 23814 AS TM (7.172/C1231/C39/C31 /C1064/(1143 Tigard, Oregon 97281 Test Methods: BY. Phone (503) 684 -3460 FAX # 684 -0954 Date Molded: 06/08 20 00 Job No. - T0004403 Permit No: ���� -00012 Client: SPE.CHT DEVELOPMENT INC - BOB BURNS Project: TIGARD CORPORATE CENTER PARKING STRUCTURE 12125 SW 69TH TIGARD OR Address: Contractor: X Sub Contractor: Concrete supplier: ROSS ISLAND SAND & GRAVEL Truck No. 21 6 V186029 Ticket No. Cast By: D. V I C K Cu. Yds. 11 OF 33 Load No . CLOUDY 60 Weather: Temp. High: Temp. Low: WALLS 9 LINE D TO E, 1 LINE A TO F. TEST AT WALL FOUNDATION Location of Placement: BETWEEN 4 AND 5 A LINE 2 :20 71 Test Time: Concrete Temp: 3500 28 4 1/2" I Strength Requirement: PSI @ days Slump Cement Type 3510B Mix NoJNo. Sacks Air Content Max. Aggregate Admix. Amount: Brand: _ Admix. Amount: Brand: Set Test@ Register Date Date Total Area Unit Report Tested rea No. Days Number Rec'd Test Load PSI No. By II 7 2461 06/09 06/15 92,800 28. 3280 AF 28 2461 06/09 07/06 133,660 28.27 4730 WR 28 2461 06/09 07/06 145,400 28.27 5140 WR 28 2461 06/09 07/06 134,960 x'8.27 4770 WR Remarks: cc: L. RS ARCHITECTS CITY OF TIGARD VL.MK / / „_ .-, •; Eck Reviewed by: . . . . .. . . . as ..,:•ti•, o hn..�nn irnm }hic nffi�o