Loading...
Report (736) Carlson Testing Inc. & Construction Inspection Related Tests Geotechnical Consulting E..X1 CONC1:F..IE RECT TVED REPORT OF TEST SPECIMENS JUN 2 1 2000 Tigard, Oregon 97281 Test Methods: ASIM C172/C12 Phone (503) 6843460 BY: '' FAX # 684 -0954 05/17 00 T0004403 ^1a .,ran -Uplj}17. Date Molded: , 20 Job No. Permi No: Client: SPEG:H I DEVELOPMENT INC -.. BOB BURNS Project: TIGARD CORPORATE CENTER PARKING STRUCTURE 12125 SW 69TH TIGARD OR Address: • Contractor: X Sub Contractor: Concrete Supplier: ROSS ISLAND SAND & GRAVEL Truck No. 75 • 1184236 Ticket No. Cast By: J . F31t YAN'I Cu. Yds. 8 OF 20 Load No. SUNNY 58 • Weather: , Temp. High: Temp. Low: ELEVATOR SHAFT WALLS .- PARKING STRUCTURE. 'ZEST AT BUILDING A Location of Placement: ROOF DLCK PAD /CURBS. 10 :30 70 Test Time: Concrete Temp: 3500 28 4 1/2" I Strength Requirement: PSI @ days Slump Cement Type 3510A Mix NoJNo. Sacks Air Content Max. Aggregate Admix. Amount: Brand: _ Admix. Amount: Brand: Set Test@ Register Date Date Total Area Unit Report Tested rea No. Days Number Rec'd Test Load PSI No. By I 7 1855 05/18 05/24 88,490 28.26 3130 AF 28 1855 05/18 06/14 99,760 28.26 3530 AF 28 1855 05/18 06/14 99,200 28.26 3510 AF 28 1855 05/18 06/14 101,620 28.26 3600 AF Remarks: � cc : I..RS ARCHITECTS / C 1:'I Y OF TIGARD VLMK ' Reviewed by: ' L. •, ' , 6 r c F7.` Y (. iY . . . . C arlson Testing, Inc. Construction Inspection & Related Tests �j��.� Geotechnical Consulting REPORT OF 1 2 CONCI' E 1 E TEST SPECIMENS JUN 2 1 2000 P.O. Box 23814 ASTM C 172 /C12_31 /C39 /C3't /C1064 /C1 Tigard, Oregon 97281 Test Methods: Phone (503) 684 -3460 FAX # 684 -0954 06/09 00 T0004403 BUP2000•- 00012 Date Molded: , 20 Job No. Permit No: Client: `;ITCH I DEVELOPMENT INC -• BOB BURNS Project: T IGARI) CORPORATE CENTLR PARKING STRUCTURE 12125 SW 69TH TIGARD 0I■ Address: Contractor: X Sub Contractor: Concrete Supplier: ROSS ISLAND SAND & GRAVEL Truck No. 208 186172 Ticket No. Cast By: P . G . SANETRA Cu. Yds. 22 OF 75 Load Not SHOWERS 5' Weather: Temp. High: Temp. Low: WALLS U FROM 3 TO 7 2ND LII="T, WALL A FROM 1 TO 3 1ST LIFT Location of Placement: AND WAI G FROM 1 TO 3 1ST LIFT. TEST AT WALL D FROM 3 TO 7 2ND LIFT. 70 Test Time: Concrete Temp: 3500 28 4 Strength Requirement: PSI @ days Slump Cement Type 3510B Mix No./No. Sacks Air Content Max Aggregate Admix. Amount: Brand: Admix. Amount: Brand: Set Test@ Register Date Date Total A Unit Report Tested Area No. Days Number Rec'd Test Load PSI No. By 7 ' 2519 06/10 06/16 94,600 28.18 3360 WR 28 2519 06/10 07/07 28 2519 06/10 07/07 HOLD 2519 06/10 Remarks: �� cc : I..RS ARCHITECTS ----- C1IY OF l 'l f- --°` VLIMK ' f Reviewed by: ._ _ ° s C. •r .••^ , ... S . . .