Report (736) Carlson Testing Inc. & Construction Inspection Related Tests
Geotechnical Consulting
E..X1 CONC1:F..IE
RECT TVED
REPORT OF TEST SPECIMENS
JUN 2 1 2000 Tigard, Oregon 97281
Test Methods: ASIM C172/C12 Phone (503) 6843460
BY: '' FAX # 684 -0954
05/17 00 T0004403 ^1a .,ran -Uplj}17.
Date Molded: , 20 Job No. Permi No:
Client:
SPEG:H I DEVELOPMENT INC -.. BOB BURNS
Project: TIGARD CORPORATE CENTER PARKING STRUCTURE
12125 SW 69TH TIGARD OR
Address:
•
Contractor: X Sub Contractor:
Concrete Supplier: ROSS ISLAND SAND & GRAVEL Truck No. 75 • 1184236
Ticket No.
Cast By: J . F31t YAN'I Cu. Yds. 8 OF 20 Load No.
SUNNY 58
•
Weather: , Temp. High: Temp. Low:
ELEVATOR SHAFT WALLS .- PARKING STRUCTURE. 'ZEST AT BUILDING A
Location of Placement:
ROOF DLCK PAD /CURBS.
10 :30 70
Test Time: Concrete Temp:
3500 28 4 1/2" I
Strength Requirement: PSI @ days Slump Cement Type
3510A
Mix NoJNo. Sacks Air Content Max. Aggregate
Admix. Amount: Brand: _ Admix. Amount: Brand:
Set Test@ Register Date Date Total Area Unit Report Tested
rea
No. Days Number Rec'd Test Load PSI No. By
I 7 1855 05/18 05/24 88,490 28.26 3130 AF
28 1855 05/18 06/14 99,760 28.26 3530 AF
28 1855 05/18 06/14 99,200 28.26 3510 AF
28 1855 05/18 06/14 101,620 28.26 3600 AF
Remarks:
�
cc : I..RS ARCHITECTS /
C 1:'I Y OF TIGARD
VLMK '
Reviewed by: ' L. •, ' , 6 r c F7.` Y (. iY
. . . .
C arlson Testing, Inc. Construction Inspection & Related Tests
�j��.� Geotechnical Consulting
REPORT OF 1 2 CONCI' E 1 E TEST SPECIMENS JUN 2 1 2000
P.O. Box 23814
ASTM C 172 /C12_31 /C39 /C3't /C1064 /C1 Tigard, Oregon 97281
Test Methods: Phone (503) 684 -3460
FAX # 684 -0954
06/09 00 T0004403 BUP2000•- 00012
Date Molded: , 20 Job No. Permit No:
Client: `;ITCH I DEVELOPMENT INC -• BOB BURNS
Project: T IGARI) CORPORATE CENTLR PARKING STRUCTURE
12125 SW 69TH TIGARD 0I■
Address:
Contractor: X Sub Contractor:
Concrete Supplier: ROSS ISLAND SAND & GRAVEL Truck No. 208 186172
Ticket No.
Cast By: P . G . SANETRA Cu. Yds. 22 OF 75 Load Not
SHOWERS 5'
Weather: Temp. High: Temp. Low:
WALLS U FROM 3 TO 7 2ND LII="T, WALL A FROM 1 TO 3 1ST LIFT
Location of Placement:
AND WAI G FROM 1 TO 3 1ST LIFT. TEST AT WALL D FROM 3 TO 7 2ND LIFT.
70
Test Time: Concrete Temp:
3500 28 4
Strength Requirement: PSI @ days Slump Cement Type
3510B
Mix No./No. Sacks Air Content Max Aggregate
Admix. Amount: Brand: Admix. Amount: Brand:
Set Test@ Register Date Date Total A Unit Report Tested
Area No. Days Number Rec'd Test Load PSI No. By
7 ' 2519 06/10 06/16 94,600 28.18 3360 WR
28 2519 06/10 07/07
28 2519 06/10 07/07
HOLD 2519 06/10
Remarks: ��
cc : I..RS ARCHITECTS -----
C1IY OF l 'l f- --°`
VLIMK '
f
Reviewed by: ._ _ ° s C. •r .••^ , ... S
. . .