Loading...
Report (730) Main Office Salem Office Bend Office P.O. Box 23814 4060 Hudson Ave., NE P.O. Box 7918 Tigard, Oregon 97281 Salem, OR 97301 Bend, OR 97708 - Carlson Testing Inc • Phone (503) 684 -3460 Phone (503) 589 -1252 Phone (541) 330 -9155 FAX (503) 684 -0954 FAX (503) 589 -1309 FAX (541) 330 -9163 c peLw— Z___ May 30, 2000 RECD IVED T0004403.CTI Permit No. BUP2000 JUN 0 2 2000 FIELD INSPECTION REPORT BY. . DATES COVERED: May 25 and 26, 2000 PROJECT: Tigard Corporate Center Parking Structure ADDRESS: 12125 SW 69th — Tigard, OR INSPECTOR: C. Stasch COP#485, WABO#STA7637001, OBOA #331 K. Thrall COP #657, WABO #THR545689, OBOA #347 05 -25 -00 (C. Stasch): A 5000 psi concrete mix 5031B form Ross Island Sand and Gravel was placed in columns D/8, 119, F /8, - F /9, G /8, G /9, F /5, F /6 FY2 — G /6, G /5, G17, G /2, G /3, E /1, E /2, D /1, D /2, C /1, B/1, and A/1. All reinforcing was inspected prior to placement of concrete and it conformed to plans. All concrete was pumped and vibrated. One set of (4) concrete test cylinders was cast. 05 -26 -00 (K. Thrall): At the request of Fred with Baugh Construction, inspected rebar in columns 3 /F, 6 /E, 7 /F, 8/E & F, 9/E & F, and wall at D/3 -7 basement —first floor first 12' lift. All rebar met City approved plans for placement grade and size. Observed the placement of and vibration of (8) cubic yards of Ross Island mix #5031 B, 5000 psi concrete to columns and second lift to columns 2 /A, B, & C and 3/A & B. One Set of test cylinders was cast with slump of 4" and temperature of 78 °F. Our reports pertain to the materials inspected /tested only. Information contained herein is not to be reproduced, except in full, without prior authorization from this office. If there are any further questions regarding this matter, please do not hesitate to contact this office. Respectfully submitted, 7 '. RLSON STING, IN ,1/4, ,4 ,... ECt -`-1\1!:- FR,C R Douglas W. Leach Chief Executive Officer CS /KT /Ijm cc: Specht Development, Inc. — Bob Burns LRS Architects City of Tigard VLMK Main Office Salem Office Bend Office P.O. Box 23814 4060 Hudson Ave., NE P.O. Box 7918 Tigard, Oregon 97281 Salem, OR 97301 Bend, OR 97708 Carlson Testing Inc. Phone (503) 684 -3460 FAX (503) 684 -0954 Phone (503) 589 -1252 Phone (541) 330 -9155 FAX (503) 589 -1309 FAX (541) 330 -9163 RECEIVED May 31, 2000 T0004403.CTI JUN 0 2 2000 Permit No. BUP2000 -00012 BY: INSPECTION REPORT DATES COVERED: May 23 and 24, 2000 PROJECT: Tigard Corporate Center Parking Structure ADDRESS: 12125 SW 69th — Tigard, OR INSPECTOR: J. Black, OBOA #392 /P.G. Sanetra COP#686, OBOA #311 J. Black 05- 23 -00: Rebar for today's work checked prior to today. Observed and tested 16 cubic yards of Ross Island mix #5031B (5000 psi fc) pumped into following location for a 5000 psi specification. Made one set of (4) cylinders. Columns (first level) grid A at 2, 3, 4, 5, 6, 7, 8, grid B.5/9, grid B at 2, 3, 4, 5, 6, 7, 8 and 9 and grid C at 2, 4, 5, 6, 8 and 9. Slump 3 3 /4" (specification 2" to 4 ") mix contains high range water reducer. Concrete temperature 76 °F, concrete mechanically vibrated. P.G. Sanetra 05- 24 -00: Checked sheet S2.1 and schedules for reinforcing for columns 1 -A, 1 -D, 1 -E, 1 -F, 2 -D, 2 -E, 2 -F, 2- G, 3 -G, 5 -F, 5 -G, 6 -F, 6 -G, 7 -G, 8 -G, 9 -F and 9 -G. All reinforcing as per drawings and schedules, all first level. Our reports pertain to the materials inspected /tested only. Information contained herein is not to be reproduced, except in full, without prior authorization from this office. If there are any further questions regarding this matter, please do not hesitate to contact this office. Respectfully submitted, ' RLSON: ESTING, INS • CHIEI- EXECUTIVE OFFICER Douglas W. Leach Chief Executive Officer JB /PGS:eam cc: Specht Development, Inc. — Bob Burns LRS Architects City of Tigard VLMK P:\ WORD \REPORTS\FI ELD \T0004403.doc • Crmstzuction Inspection & Related Tests Carlson Testing Inc. C WED Geotechnical Consulting JUN 0 2 2000 REPORT OF fiX'12 CONCRETE TEST SPECIMENS P.O. Box 23814 ASTM C172/C123.1/C39/C31/C1064/C143 BY: Tigard,Oregon97281 Test Methods: Phone (503) 684 - 3460 FAX # 684 -0954 Date Molded: t 15 , 20 00 Job No. T0004403 Permit No: BUP2000- -0()0 Client: SI'EC1I1 DEVELOPMENT INC - BOB BURNS Project: TIGARD CORPORATE CENTER PARKING STRUCTURE Address: 12125 SW 69TH TIGARD OR Contractor: X Sub Contractor: Concrete supplier: ROSS ISLAND SAND & GRAVEL T ruck No. 93 Ticket No. V 18392.9 • D.V1CK Cast By: Cu . Yds. 7 -' OF 247 4 7 Load No. CLOUDY 55 Weather: Temp. High: Temp. Low: CRANE FOOTING, SPREAD FOOTINGS 313, 4B, 5F, 6F, CONTINUOUS Location of Placement: FOOTINGS D LINE 3 TO 7, 9 LINE F TO G, G I..INE 5 [0 9 AND STRAP BEAMS 5 -F TO G 6-F TO G 10:50 Test Time: 6 9 Concrete Temp: 3000 PSI @ 28 days Slum 4" „ Cement Type Strength Requirement: y p yp 300013 Mix NoJNo. Sacks Air Content Max. Aggregate Admix. Amount: Brand: — Admix. Amount: Brand: Set Test@ Register Date Date Total Area Unit Report Tested rea No. Days Number Rec'd Test Load PSI No. By 1 7 1782 05/16 05/22 101,280 28.26 3580 WR 14 1782 05/16 05/29 130,260 2.8.2.7 4610 WR 28 1782 05/16 06/12 28 1782 05/16 06/12 i Rem ` . T Al ' #2 FOOTING BETWEEN B . 5 AND E. 5 AT 3 LINE ' /::" cc: I...RS ARCHITECTS ,. CITY OF TIGARD � VLMK Ge' L_^ ^nr>PTpr:Y MANAGER Reviewed by: • . _ ...... . _ _....,, ti., .. --- +...... + o' 111 u.ithn. 4 nrinr o. .thnri,atinn from thls office. coon Inspection & Related Tests Carlson Testing, Inc. �=�� ' Geotechnical Consulting j U N U 2000 REPORT OF f:�X l /.. CONCRETE F_. TEST SPECIMENS 113Y P.O. Box 23814 A `.iTM C172 /C12.31/C39/C31/C1064/C:14 Tigard, Oregon 97281 Test Methods: Phone (503) 684 -3460 FAX # 684 -0954 Date Molded: 05/15 , 20 00 Job No. T0004403 permit No: BUP2000 000 1 2. Client: SPECFIT DEVELOPMENT INC - BOB BURNS Project: TIGARD CORPORATE CENTER PARKING STRUCTURE Address: 12125 SW 69TH TIGARD OR Contractor: Sub Contractor. Concrete Supplier: ROSS ISLAND SAND & GRAVEL Truck No. 212 Ticket No. A184001 D. V I CK 131 OF 247 Cast By: Cu. Yds. Load No . 3 SUNNY 56 Weather: Temp. High: Temp. Low: CRANE FOOTING, SPREAD FOOTINGS 313, 4f3, 5F, 6F, CONTINUOUS Location of Placement: FOOTINGS U LINE 3 TO 7, 9 LINE F TO G, G LINE 5 .1..0 9 AND STRAP BEAMS 5 -F TO G 6 -F TO G 11 :30 69 Test Time: Concrete Temp: 3 0 0 0 P S I ® 28 days Slump Cement 1/4" Cement Typ & I I Strength Requirement: 30006 Max. Aggregate Mix NoJNo. Sacks Air Content Admix. Amount: Brand: — Admix. Amount: Brand: Set Test@ Register Date Date Total Area Unit Report Tested rea No. Days Number Rec'd Test Load PSI No. By I.I 7 1781 05/16 05/22 86,100 28.26 3050 WR 14 1781 05/16 05/29 116,320 28.26 4120 WR 28 1781 05/16 06/12 28 178.1 05/16 06/12 Rern fPiT AT TOWER CRANE FOOTING . , . ,--. OOT I NG -�_ cc : LRS ARCHITECTS f� n r cm I�Y OF TIGARD • .,/ ! "' VLMK Reviewed by: • . . • •. . ,. . __ ___._ .. . : • . • h .. ..n.1 ..4 1 in (nil wirhn,rt nrinr authorization from this office. Construction Inspection & Related Tests Carlson Testing, Inc. "~�'' Geotechnical Consulting JUN 0 2 2000 REPORT OF TEST 12 CONCRETE TEST SPECIMENS P.O. Box 23814 Test Methods: ASTM 0172 /C12..31/C39/C31/C1064/C143 'L'1' Tigard, Oregon 97281 Phone (503) 684 -3460 FAX # 684 -0954 Date Molded: 05/15 20 00 Job No. T0004403 Permit No: BUP2000- •0001 Client: SE F CI DEVELOPMENT INC - BOB BURNS Project: TIGARD CORPORATE CENTER PARKING STRUCTURE Address: 12125 SW 69TH TIGARD OR Contractor: X Sub Contractor: Concrete supplier: ROSS ISLAND SAND & GRAVEL Truck No. 75 Ticket No. A 184016 D. V I C K 222 OF 247 Cast By: Cu. Yds. Load No? L SUNNY 63 Weather: Temp. High: Temp. Low: CRANE FOOTING, SPREAD FOOTINGS 313, 48, 5F, 6F, CONTINUOUS Location of Placement: FOOTINGS D LINE 3 TO 7, 9 LINE F TO G, G LINE 5 TO 9 AND STRAP BEAMS 5-F TO G 6-F TO Cr • 6 9 1 Test Time: i.li) Concrete Temp: 3000 Strength Requirement: PSI @ 28 4 days Slump Cement Typ & 1 I 300013 Mix NoJNo. Sacks Air Content Max. Aggregate Admix. Amount: Brand:. Admix. Amount: Brand: Set Test@ Register Date Date Total Area Unit Report Tested rea No. Days Number Rec'd Test Load PSI No. By II.I 7 1783 05/16 05/22 90,840 28.2.6 3210 WR 14 1783 05/16 05/29 121,920 28.2.6 4310 WR 28 1783 05/16 06/12 28 1783 05/16 06/12 Rern iV. 5. .T AT SPREAD FOOTING 5F " cc : LRS ARCHITECTS ' CITY OF TIGARD / /'- ,/ . ---------_— VLMK / Reviewed by: +_. c. "., ^ T() M . N A G E R _.. _ ._� _..__ _ • + • • hn .nn.n.inru.l tin fall wi�hrnd nri authorization from this office.