Report (757) Main Office Salem Office Bend Office P.O. Box 23814 4060 Hudson Ave., NE P.O. Box 7918 Tigard, Oregon 97281 Salem, OR 97301 Bend, OR 97708 Carlson Testing Inc. Phone (503) 684 -3460 FAX (503) 684-0954 Phone (503) 589 -1252 Phone (541) 330 -9155 FAX (503) 589 1309 FAX (541) 330 -9163 o tfeI1.- 1 kP —ciGr / May 22, 2000 T0004403. CTI Permit No. BUP2000 -0 - RECF" I TED INSPECTION REPORT MAY 2 4 2000 DATES COVERED: May 19, 2000 BY. PROJECT: Tigard Corporate Center Parking Structure ADDRESS: 12125 SW 69th — Tigard, OR INSPECTOR: M. Larson, COP #625 05- 19 -00: Checked rebar cages for the parking garage in the following areas. Cages were not in place at this time. C9, A8, B.5/9, C8, B8, A7, C6, G7, D8, A4, A5, A6, B5, C5 and boundary elements C7 and E7. Rebar in these cages were to plans and specifications. Adequate rebar lap and clearances should be checked again before pour. No concrete poured, no tests taken. Our reports pertain to the materials inspected /tested only. Information contained herein is not to be reproduced, except in full, without prior authorization from this office. If there are any further questions regarding this matter, please do not hesitate to contact this office. -spectfully submitted, RLSON STING, INC y CHIEF EXECUTIVE OFFICER Douglas W. Leach Chief Executive Officer ML:eam cc: Specht Development, Inc. — Bob Burns LRS Architects City of Tigard VLMK Main Office Salem Office Bend Office P.O. Box 23814 4060 Hudson Ave., NE P.O. Box 7918 Inc. Tigard, Oregon 97281 Salem, OR 97301 Bend, OR 97708 Carlson Testing c Phone (503) 684-3460 FAX (503) 684-0954 Phone (503) 589 -1252 Phone (541) 330 -9155 FAX (503) 589 1309 FAX (541) 330 -9163 May 44 0 3.0 TI RECFIVED T000443.0 Permit No. BUP2000 -00012 MAY 2 4 2000 INSPECTION REPORT BY DATES COVERED: May 17, 2000 PROJECT: Tigard Corporate Center Parking Structure ADDRESS: 12125 SW 69th, Tigard, OR INSPECTOR: J. Bryant COP#586, OBOA #137, WABO#BRY523915 05- 17 -00: Inspected rebar placed at Building A roof deck pad and curbs, parking structure elevator shaft walls, footing pads line 2 @ B through F, footings, line G from 1 to 3, line lfrom A to F and line A from 1 to 4. All rebar was placed, in compliance with approved plans. Monitored the pouring of 20 cubic yards concrete, Ross Island mix 3510B at parking structure roof deck pad and curbs and Building A elevator shaft walls. Monitored the pouring of 80 cubic yards concrete, Ross Island mix 3010B at continuous footings listed above. One set of test cylinders was molded for each mix poured. Our reports pertain to the materials inspected /tested only. Information contained herein is not to be reproduced, except in full, without prior authorization from this office. If there are any further questions regarding this matter, please do not hesitate to contact this office. Respectfully submitted, I) CARLSON TESTING, Li P . - f 1. _,.,..,; 4 , CHIEF EXEC1!T!VE OFFICER Douglas W. Leach Chief Executive Officer JB:tkf cc: Specht Development, Inc. — Bob Burns LRS Architects City of Tigard VLMK