Loading...
Report (614) Main Office Salem Office Bend Office P.O. Box 23814 4060 Hudson Ave., NE P.O. Box 7918 Tigard, Oregon 97281 Salem, OR 97301 Bend, OR 97708 Carlson Testing Inc. Phone (503) 684 -3460 Phone (503) 589 -1252 Phone (541) 330 9155 FAX (503) 684 -0954 FAX (503) 589 1309 FAX (541) 330 -9163 OW F5f6,cIUz:3 2-- May 11, 2000 CE!VED T9902536.CTI MAY 1 5 2000 Permit No. BUP1999- 00232/00440 BY. . INSPECTION REPORT DATES COVERED: May 10, 2000 PROJECT: Tigard Corporate Center — Building A ADDRESS: 12123 SW 69th, Tigard, OR INSPECTOR: G. Seamster ICBO #5006921 -85 05- 10 -00: CTI representative was onsite and the following was noted. 1. Performed visual inspection of additional roof reinforcement under new mechanical unit between grid line A- B/3 -5. Welding appears to conform to engineer revised detail 05 -03 -00 (see CTI report dated 05 -04 -00 for details), plans, specifications and AWS D1.1. 2. Verified torque value after installation of (2) %" diameter x 6" long Ramset wedge anchors at 175 ft/Ibs per ICBO report #1372. Anchors were reinstalled at grid lines A/3-4 roof line into existing tilt up wall for joist ledger (reference CTI report dated 05- 04 -00). Wedge anchors achieved a 4" minimum embedment per details of engineer revised detail 5 (see file for detail). Our reports pertain to the materials inspected /tested only. Information contained herein is not to be reproduced, except in full, without prior authorization from this office. If there are any further questions regarding this matter, please do not hesitate to contact this office. Respectfully submitted, _, i) CARLSe TESTING, 0, . Douglas W. Leach Chief Executive Officer GS /Ijm cc: Specht Development, Inc. — Bob Burns City of Tigard Building Department Baugh Construction Co. LRS Architects VLMK Carlson Testing, Inc. Construction Inspection & Related Tests Geotechnical Consulting REPORT OF6X 1? CONCRETE TEST SPECIMENS P.O. Box 23814 Test Methods: ASTM C172/C1231/C39/C31/C1064/C143 Tigard, Oregon 97281 Phone (503) 684-3460 FAX # 684-0954 Date Molded: Job No. 05/17 ,20 00 T9902536 permallo: BUP1999-00232/004 40 Client: SPECHT DEVELOPMENT INC - BOB BURNS Project: 11GARD CORPORATE CENTER - BLDG A RECIFTVED MAY 3 0 2000 Address: 12123 SW 69TH *TIGARD OR BY: 1 BAUGH CONSTRUCTION CO Contractor: Sub Contractor: ROSS ISLAND SAND & GRAVEL 1184236 Concrete Supplier: R Truck No. 75 Ticket No. J. Cast By: BRYANT C u. Cu Yds. 8 OF Load No. SUNNY 58 Weather: Temp. High: Temp. Low: ELEVATOR SHAFT WALLS -. PARK I NG STRUCTURE . TEST AT 131111..01 NG A Location of Placement: ROOF DICK PAD/CURBS. 10:30 70 Test Time: Concrete Temp: 3500 28 4 1/2" I Strength Requirement: PSI @ days Slump Cement Type 3510A Mix NoJNo. Sacks Air Content Max. Aggregate Admix. Amount: Brand: Admix. Amount: Brand: Set Test@ Register Date Date Total Unit Report Tested No. Days Number Rec'd Test Load Area PSI No. By 1 7 .1855 05/18 05/24 88,490 28.26 3130 AF 28 1855 05/18 06/14 28 1855 05/18 06/14 HOLD 1855 05/18 Remarks: ./' cc: CITY OF TIGARD BUILDING DEPT - BAUGH CONSTRUCTION CO / / -- LRS ARCHITECTS VLMK ./ ._i%:?C;Fie-ORYMANAGER Reviewed by: au ithnri7ation from this office. Carlson Testi Construction Inspection & Related Tests ng , Inc. Geotechnical Consulting 7 T! ,9 . P"� 7 \/ D I�X 12 CONCRETE _:. REPORT OF TEST SPECIMENS J • 2 1 2000 P.O. Box 23814 ASTM C172/C1231/C39/C3)/C1064/C)43 ! Tigard, Oregon 97281 Test Methods: Phone (503) 684 -3460 s- FAX # 684 -0954 Date Molded: 05/17 9 .00232 /004 20 00 Job No. (9902538' Permit No: 40 Client: S('CC:11T DEVELOPMENT INC -• HOB BURNS Project: (I GARI) CORPORATE CENTER -- BLDG A 12123 SW 69T11 TIGARD OR Address: hHAUGH CONSTRUCTION CO Contractor: Sub Contractor: Concrete Supplier: ROSS ISLAND SAND & GRAVEL Truck No. 75 f 184236 Ticket No. Cast By: J.BRYANT Cu. Yds. 8 OF 20 Load No . 1 SUNNY 58 Weather: Temp. High: Temp. Low: _ ELEVATOR SHAFT WALLS - PARKING STRUCTURE. TEST AT BUILDING A Location of Placement: ROOF DECK PAD/CURBS. 10:30 70 Test Time: Concrete Temp: 3500 28 4 1/2" 1 Strength Requirement: PSI @ days Slump Cement Type 3510A Mix NoJNo. Sacks Air Content Max. Aggregate Admix. Amount: Brand: — _ Admix. Amount: Brand: Set Test@ Register Date Date Total Area Unit Report Tested No. Days Number Rec'd A Test Load PSI No. By I 7 ' 1855 05/18 05/24 88,490 28.26 3130 AF 28 1855 05/18 06/14 99,760 28.26 3530 AF 28 1855 05/18 06/14 99,200 28.26 3510 AF 28 1855 05/18 06/14 101,620 28.26 3600 AF Remarks: c: r_ /rC:I I Y OF I BUILDING DEPT /;" .' -'' BAUGH CONSTRUCTION CO ,-. . J LRS ARCHITLCTS �,., VLMK Reviewed by: - ' M `. '!AGE R • . . . .. • , ....__ .1.,..,,,J • '.. •,.1i ..,;,h..,,, "win, o..fhnri7'.itinn from this office.