Permit CITY OF TIGARD PLUMBING PERMIT • . ; r 4 DEVELOPMENT SERVICES PERMIT #: PLM1999 -00258 ,1,1� „� 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 DATE ISSUED: 8/12/99 SITE ADDRESS: 12123 SW 69TH AVE PARCEL: 2S101AA -TTOOA SUBDIVISION: TIGARD TRIANGLE OFFICE COMPLEX ZONING: MUE BLOCK: LOT: OOA JURISDICTION: TIG CLASS OF WORK: NEW GARBAGE DISPOSALS: MOBILE HOME SPACES: TYPE OF USE: COM WASHING MACH: BACKFLOW PREVNTRS: 1 OCCUPANCY GRP: B FLOOR DRAINS; 4 TRAPS: 1 . STORIES: WATER HEATERS: 1 CATCH BASINS: FIXTURES LAUNDRY TRAYS: SF RAIN DRAINS: SINKS: 2 URINALS: 2 GREASE TRAPS: LAVATORIES: 8 OTHER FIXTURES: 13 TUB /SHOWERS: 2 SEWER LINE: 100 ft WATER CLOSETS: 10 WATER LINE: 100 ft DISHWASHERS: RAIN DRAIN: 100 ft Remarks: Plumbing - shell. Other fixtures: 3 hose bibs, 8 roof drains, 2 drinking fountains. Trap is really a sump pump. FEES Owner: Type By Date Amount Receipt TIGARD CORPORATE CENTER LP PRMT BON 8/12/99 $686.00 99- 317595 15400 SW MILLIKAN PLCK BON 8/12/99 $171.50 99- 317595 BEAVERTON, OR 97006 5PCT BON 8/12/99 $34.30 99- 317595 Phone 1: Total $891.80 Contractor: • MACDONALD- MILLER COMPANY 7717 DETROIT AVE SW SEATTLE, WA 98106 REQUIRED INSPECTIONS Water Service Insp Phone 1: Reg # : LIC 00063593 Top-out asp g Storm Drain Insp PLM 37 -64PB Rain Drain Insp RP /Backflow Preventer Final Inspection ° RIG/A/A This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable laws. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more than 180 days. ATTENTION: Oregon law requires you to follow rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952 - 0001 -0010 through OAR 952 - 0001 -0080. You may obtain copies of these rules or direct questions to OUNC by calling (503 24•- 987. /� / Issued By:' • ( �A (w'` Permittee Signatu : „AI ...-iiw Call (503) 639 -4175 by 7:00 P.M. for an inspection neede. j1 ext business day CITY OF TIGARD I . P lumbing Permit Application Plan Check ft [''�t. 13125 SW HALL BLVD. Commercial and Residential Reed By TIGARD, OR 97223 Date Recd - 4- (503) 639 -4171 - - Date to P.E. - P - 9 - Print or Type Date to DST 1el 0 ` 9 Permit ft: 1.-(14 - CISIZSi Incomplete or illegible applications will not be accepted Related SWR ® `,w4i Caned Name of Development/Project ; FIXTURES ;(individual) QTY PRICE AMT Job Tl f � ai,l�d !orporak rr (01- Sink ,�Gnitor 5 kg 11.50 r o o f) Address Stan A "--°° �j Sure Lavatory ,,,> 11.50 00 _:' t Z:3 l9 _ I _ Tub or Tub/Shower Comb. 11.50 • 8 State �P Shower Only - 1,„-2„ 11.50 1 3,1 ,ci I ( Water Cioset Name �Q 11.50 J15 W 1 , Dishwasher 11.50 Owner . Mailing Ad r e � C Suite Garbage Disposal 11.50 54 d � (I i Washing Machine 11.50 /State Zip Phone p of , i, z 1.,1 'f l� 11 _ --1i0 1 Floor Drain/Floor Sink 2' 11.0 'Lilo a me •YUn V o l lY 4' 11.50 . Occupant Mailing Address Suite Water Heater 0 conversion 0 like kind 11.50 Gas piping requires a separate mechanical permit. ( A15 City /State Zip Phone Laundry Room Tray 11.50 Urinal V 11.50 25 ,.r. Name \ Other Fixtures (Specify) ' f� 1�Q caul( Ca a' 4I I I,e r f 6Se, d, �S �� ^ - Is.te Contractor Mailing 5E- l Z Suite ktmj tr un-S 1 toy' Prior to permit , ity /State Zhone Sewer - 1st 10' / 38.00 , pi issuance, a Copy C Q ulla, 02 Zip 721 1 250- -Iper' q Sewer - each additional 100' 32.0 of all licenses are Oregon Const. Cont. Board Licit Exp. Dat req if (c35 CI 0 1111400 Water Service - 1st 100' i 38.00 , expired database se 2 Plumbing U x 14 PiS _ r Exn I � ell Storm Rain Drain - l st 1 O ' 38 00 7 j ,° D e - each additional 200' Name "• l l0l ) Storm & Rain Drain - each additional 100' 32.00 , Architect 1475 it - 1(4; k(,1s Mobile Home Space 32.00 or Mailing Address • Suite Commercial Back Flow Prevention Device or Anti- - i 32.00 H.ZI S(Jl)�)u.t know 100 Pollution Device *z,(13 Engineer Clty/State ' Z Phone Residential Backflow Prevention Device* 19.00 ) ! et,�d, OE Ze5 2.21 -1121 (Irrigation timing devices require a separate Describe work to be done: restricted energy permit) New • Repair 0 Replace with like kind: Yes 0 No 0 Any Trap or Waste Not Connected to a Fixture 1 11.50 i i ,go Residential 0 Commerdal • CatelrBasi Sn P 114 M p/ 11.50 ?f, , ' Additional description of work Insp. of Existing Plumbing 50.00 per/hr • Are you capping, moving or replacing any fixtures? Specially Requested Inspections 50.0 per/hr Yes 0 No O 5.00 - Rain Drain, singlefamily dwelling 45.00 If yes, see back of form to indicate work performed by Grease Traps 11.50 fixture. FAILURE TO ACCURATELY REPORT FIXTURE WORK COULD RESULT IN INCREASED SEWER FEES. QUANTITY TOTAL 2-' . I hereby acknowledge that I have read this application, that the Information Isometric a riser diagram is required if Quantity Taal Is > 0 given is correct, that I am the owner or authorized agent of the owner, and *SUBTOTAL � that plans submitted are in compliance with Oregon State Laws. t� W Signature of • e (. gent Vt iv..N Dane � 5% SURCHARGE • � ,1 3 b � 7i L Contact Person • ame Phone "PLAN REVIEW 25% OF SUBTOTAL //.50 t @S V0.y_€ V-- Z . b41q I Required only it fixture qty. total is > 9 I G1 . ,;I \Tti PUSE,$1ZR.00 TOTAL ( t 11 v '8 52 .oD � , • * _, Th E O Q� = ': , Sri r t'::::-' Minimum permit fee is $50 + 5% surcharge, except Residential Backflow r c fe.iriatNdes eUi tumbing,fbt#'uses InIhe Irng'and tho Mitt f °, Prevention Device, which Is $25 + 5% surcharge 1 #21*aflifirlYaktftt at ntt er att~ct iLr jk _.' "Ali New Commercial Buildings require plans with isometric or riser diagram and plan review tVli ormslpkanapp.doc 6/1/99 J • PLEASE COMPLETE: • • ..... ..... .......................:::..:...........:.:....:................................................ ..................::.:... ...... New.:.::::::..::..:.........:..::..:...::::...........................................:.::............ ............................... Sink . 2 Lavatory Tub or Tub /Shower Combination Shower Only Water Closet /0 Dishwasher • Garbage Disposal Washing Machine Floor Drain /Floor Sink 2" 3 „ 4" • Water Heater. • f Laundry Room Tray • Urinal 0.3 Other Fixtures (Specify) Dd- / iCt� F , ra c'1 S • • COMMENTS REGARDING ABOVE: P ./iii MV 1 LAdsbsVomilkkanaPP.doc • • CITY OF TIGARD BUILDING INSPECTION DIVISION . MST 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 BUP Date Requested ) y /ZR AM PM BLD Location 1 21 2 (91 Ave, �a' Suite MEC ) / Q L7 ([ Contact Person f, Ph 5 PLM Contractor Ph SWR BUILDING Tenant/Owner ELC Retaining Wall ELR Footing Acces - FPS Foundation Ftg Drain % SGN Crawl Drain Inspectio otes: Slab SIT Post & Beam Ext Sheath /Shear Int Sheath /Shear Framing Insulation Drywall Nailing Firewall Fire Sprinkler Fire Alarm Susp'd Ceiling Roof /7 Misc: ' f Final \ PASS PART FAIL MBIf IG � Post & Beam Under Slab Top Out Water Service _ Sanita Sewer in Drains - 11 S PART FAIL �l ( _ NI Post & Beam • • In a Lip • Smoke Dampers Fi P - PART FAIL ECTRICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA Approach /Sidewalk Date , Inspector Ext Other Final PASS PART FAIL DO NOT RE OVE this inspection record from the job site. CITY OF TIGARD BUILDING INSPECTION DIVISION MST 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 / (�I BUP Date Requested �G2 / l t7 / % AM PM BLD Location / Z / 2.3 S w 9 ride Suite MEC Contact Person Ph pL /99' 9 -00 Z5'S Contractor Ph SWR BUILDING Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: Slab SIT Post & Beam Ext Sheath /Shear Int Sheath /Shear Framing Insulation I )� Drywall Nailing /� �� o &!(-1 16. Firewall Fire Sprinkler Fire Alarm Susp'd Ceiling Roof Misc: Final P RT FAIL MBI Beam Under Slab Top Out Water Service Sanitary Sewer Rain Drains Fi AS PART FAIL MECHANICAL Post & Beam Rough In Gas Line Smoke Dampers Final PASS PART FAIL ELECTRICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA //6/ �\ ��1� Approach /Sidewalk Date / z 9 7 Inspector v , " / Ext Other / Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site. • CITY OF TIGARD BUILDING INSPECTION DIVISION MST 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 / BUP Date Requested /1 ?-mil Q9 AM PM BLD Location 0-1 .-3 5w u=1* Suite MEC Contact Person d- Ph 5 '? PLM r! q q'C Contractor Ph 2 'j/ 6 SWR BUILDING Tenant/Owner i I ` �� n ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: L L 4 Slab SIT Post & Beam < j_ , � U rK. l C � a Ext Sheath /Shear rX- I Int Sheath /Shear Framing Insulation Drywall Nailing 1 ' i ry / /p , /g 6 a24 gy /4 T t �JG1 ,—ax_ ,—ax_ c/ Fire wall ( b ,zi- 6& 0/Le c /e 7 (J r � Fire S rinkler Fire Alarm Susp'd Ceiling Roof Misc: Final PA ART FAIL UMBING eam nder Slab Top ut er Service Sanitary Sewer Rain Drains Final PART FAIL ANICAL Post & Beam Rough In Gas Line Smoke Dampers Final PASS PART FAIL ELECTRICAL Service Rough In UG /Slab , Low Voltage Fire Alarm Final PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ - required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin �s Fire Supply Line [ ] Please call for reinsp ction RE: [ ] Unable to inspect - no access ADA Approach /Sidewalk Date � i Inspector �^ Ext Other f Final PASS PART FAIL D NOT RE OVE this inspectio‘n record rom the job site. CITY OF TIGARD BUILDING INSPECTION DIVISION MST 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 �/ • BUP Date Requested .�j� 10 AM C1 PM BLD Location I 2-1 23 � l p� t' ` . 4'Lj < � Suite MEC Contact Person G'//( Ph S'22-- PLM S Contractor Ph SWR riff BUILDING Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS n Cr g SGN Crawl l Drain Inspection Notes: Slab SIT Post & Beam Ext Sheath /Shear Int Sheath /Shear Framing Insulation Drywall Nailing Firewall Fire Sprinkler La Fire Alarm g (T� a y --eaC / Susp'd Ceiling Roof / / / U 5 TAI$ 7 F Final PASS PART FAIL BIN � Post & Beam Under Slab Top Out Water Service Rain rains Fin - PART FAIL ANICAL • Post & Beam Rough In Gas Line Smoke Dampers Final PASS PART FAIL ELECTRICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL SITE Backfill/Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin [ ] Please call for reinspection RE: [ ] Unable to inspect - no access Fire Supply Line ADA ( D1 Q Approach /Sidewalk Date /0 (7 I _ / / Ins Other �� Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site. CITY OF TIGARD BUILDING INSPECTION DIVISION MST 24 -Hour Inspection Line: 639 -4175 Business Line: 639-4171 / /'? BUP to Date Requested C/ AM PM BLD Location /d-10 10 Suite MEC Contact Person 6(10." b Cj O . Ph f 9 3 " 9 PL q c l - Contractor Ph SWR . BUILDING Tenant/Owner ELC Retaining Wall ELR Footing Access Foundation jAtarLy) '--- e fi rPe - � t� FPS Ftg Drain Q / �j /� SGN Crawl Drain I e Slab l /d ►� -�lL / Tw SIT Post & Beam Ext Sheath /Shear Int Sheath /Shear Framing Insulation Drywall Nailing Firewall Err Fire Sprinkler _ _ Fire Alarm / J/ Susp'd Ceiling • 1 — ! Roof Misc: Final PASS PART FAIL MBI Post & Beam Under Slab Top Out Water Service Sanitary Sewer A 4 : 1 ! PART FAIL MECHANICAL Post & Beam Rough In Gas Line Smoke Dampers Final PASS PART FAIL ELECTRICAL Service Rough In UG /Slab Low Voltage �u Fire Alarm Final PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA Approach /Sidewalk D /6 (1 q' Inspector 12n - Other Ext Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site. 1� CITY OF TIGARD BUILDING INSPECTION DIVISION MST 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 BUP Date Requested 1 f �. OD AM PM BLD Location 1 2- 1 (a'? Suite MEC Contact Person Ph S' PLM /4 ' / cZScf Contractor Ph SWR BUILDING Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: Slab SIT Post & Beam Ext Sheath /Shear Int Sheath /Shear Framing Insulation Drywall Nailing i _ , Firewall �,�/ � j Fire Sprinkler / 1' !� � r ��` • Fire Alarm Susp'd Ceiling Roof Misc: F J inal PASS PART FAIL eMIEHER Post & Beam Under Slab Top Out � Sanitary Sewer /l Rain Drains • PART FAIL HANICAL Post & Beam Rough In Gas Line Smoke Dampers Final PASS PART FAIL ELECTRICAL Service Rough In UG /Slab Low Voltage / Fire Alarm Final PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA Approach /Sidewalk Date if I 2 1 U O Inspector 9T1 Ext Other Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site. CITY OF TIGARD BUILDING INSPECTION DIVISION 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 MST L' BUP Date Requested l AM PM BLD Location 91-4- /1 Suite MEC Contact Person . (3a4-- Ph c57.2 — 7/ PLM lc( q� czS ' Contractor Ph SWR BUILDING Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: /� Slab �C g i SIT Post & Beam Ext Sheath /Shear Int Sheath /Shear Framing Insulation Drywall Nailing Firewall Fire Sprinkler Fire Alarm Susp'd Ceiling Roof Misc: Final PASS PART FAIL PLUMBING Post & Beam Under Slab 6 ter Service '' Water Sanitary Sewer Rain Drains Final PART FAIL CHANICAL Post & Beam Rough In Gas Line Smoke Dampers Final PASS PART FAIL ELECTRICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL SITE Backfill/Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA �!� Approach /Sidewalk Date Inspector_ __ � ___ Ext Other Final PASS PART FAIL D N T REMOVE this inspection record from the job site.