Plans MICHAEL K. BROWN RECEIVED
Registered Professional Structural Engineer
In Partners with S E P 0 2 2010
`-,trir, tr,rai LrrrrnEer-,
CITY OF TIGARD - .t Fide t ' 'et- `�t it, v,r l
C C R E BUILDING DIVISION ,et,
ENGINEERING Pi'
•
, ,I f' , >r ,r1III rVru i '1 t
LATERAL STRUCTURAL DESIGN
CALCULATIONS
FOR
LOT 110, ARLINGTON HEIGHTS
TIGARD, OR
ENGR. JOB # DM10 -050
g oolizttp
• Prepared for: Lr _ .7
StoneBridge Homes, NW, LLC
Plan #: 199
OTE: 1481
Date: 9-01 -2010
The following calculations are for lateral wind and seismic engineering only. Gravity loading and the design of foundations
are outside the scope of this design. The design is based on information provided by the client who is solely responsible
for its accuracy. The engineering represents the finished product. Discrepancies from information provided by the client
invalidate this design. Core Engineering shall have no liability (expressed, or implied), with resped to the means and
methods of construction workmanship or materials.
Core Engineering, PLLC. shall have no obligation of liability, whether arising in contract (including warranty), Tort
(including active, passive, or imputed negligence) or otherwise, for loss or use, revenue or profit, or for any other
incidental or consequential damage
r
INSTALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER.
CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS, CSA 2.33, ANSI Z21.88 FOR VENTED GAS FIREPLACE HEATERS
\ f 1/
RECEIVED
.. ‘,,
SEP O 2 2010 ;i lit
CITY OF TIGARD i
BUILDING DIVISION f
Ilk
CONTI :;2 '-
• FIREPLACES •
DIRECT VENT MILLIVOLT SYSTEM
INSTALLATION AND OPERATION INSTRUCTIONS FOR
f NATURAL GAS MODEL CDV36NTR & BCDV36NTR
PROPANE GAS MODEL CDV36PTR & BCDV36PTR
CERTIFIED FOR CANADA AND UNITED STATES USING ANSI / CSA METHODS
WARNING: If the information in these instructions is not followed exactly, a fire or
explosion may result causing property damage, personal injury or death.
FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapours and liquids in the vicinity of
this or any other appliance.
WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance. • Immediately call your gas supplier from
• Do not touch any electrical switch. a neighbour's phone. Follow the gas
• Do not use any phone in your build supplier's instructions.
ing. • If you cannot reach your gas supplier,
call the fire department.
Installation and service must be performed by a qualified installer, service agency
or the gas supplier.
O 9 °O1 ep Warnock Hersey luso
Az. R -2000 ' , 11'rioIn us
J
v �+
s
L
9
J 1WIOI�f�lb \BfOK1• r D�l'a \,t`Z
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4YB Canada : (705)721 -1212 • tax(705)722-6031
www.continentalfireplaces.com • ask @continentaltire.com
W415-0211/ G/07.04.03
5
CDV36;. SPECIFICATIONS- BCDV36 - SPECIFICATIONS -
l A MIME A Wild
35 I 35 h' 1
24 Vi ' 24 'le
33' S 'h' GAS 32 Ali 5'h' INLET
I INLET
3' Ili
3' T lllli T
ELECTRICAL INLET 1_27• J ELECTRICAL INLET
1 .----27' LEFT SIDE I LEFT SIDE
4' 0 I I
1 ; :_ ' —f 14'
7 D m 1 I 1 j • 1I 'h . m 12 � 12'li J
Lim.,"
I
18 Ns" — 18•-1 -I I FIGURE la 3r I FIGURE lb
37 'le
VENTING
MODELS CDV36 AND BCDV36 MAY BE VENTED EITHER AS A TOP VENT OR A REAR VENT.
REFER TO THE SECTION APPLICABLE TO YOUR INSTALLATION.
VENTING . LENGTHS For optimum performance it is recommended that all
horizontal runs have a 1 inch rise per foot when using
Use only Wolf Steel or Simpson Dura -Vent Model DV -GS Wolf Steel flexible vent components.
venting components. Minimum and maximum vent lengths, A terminal shall not terminate directly above a sidewalk
for both horizontal and vertical installations, and air termi- or paved driveway which Is located between two sin -
nal locations for either system are set out in this manual g/e family dwellings and serves both dwellings. Local
and must be adhered to. For Simpson Dura -Vent, follow codes or regulations may require different clearances.
F : the installation procedure provided with the venting com- D not a / /ow the inside liner to bunch up on horizontal or
E ponents. vertical runs and elbows. Keep It pulled tight. A 1' -"air
When using Wolf Steel venting components, use only ap- gap all around between the inner liner and outer liner is
proved Wolf Steel rigid / flexible components with the fol- required for safe operation. Use a firestop when pen -
lowing termination kits: WALL TERMINAL KIT GD222, or etrating interior walls, floor orcei/ing.
1/12 TO 7/12 PITCH ROOF TERMINAL KIT GD110, 8/12 TO Minimum clearance to combustible con -
12/12 ROOF TERMINAL KIT GD111, FLAT ROOF TERMI struction from fireplace and vent surfaces:
NAL KIT GD112 or PERISCOPE KIT GD201 (for wall pen-
etration below grade). With flexible venting, in conjunction sides, back, bottom and top of the unit 0 inch
with the various terminations, use either the 5 foot vent kit recessed depth 14 inches
GD220 or the 10 foot vent kit GD330. top, sides and bottom of the vent pipe* 1 inch
Wolf Steel rigid and flexible venting systems must not top of the vent pipe - rear vent only* 2 inches
be combined. '` REAR VENT - A clearance to combustibles of 1" at the
Wolf Steel and Simpson Dura -Vent venting systems bottom of the vent and 2" at the top must be maintained
must not be combined. during the first 12" of venting when penetrating combusti-
These vent kits allow for either horizontal or vertical venting ble walls. The firestop spacer (W615 -044) supplied with
of the fireplace. FIGURES 3 & 5. The maximum allowable the unit should be used to maintain this clearance. There -
horizontal run is 20 feet. The maximum allowable vertical after a 1" clearance to combustibles may be maintained
vent length is 40 feet. The maximum number of 4" vent using firestop spacer (W500- 0096).
connections is two horizontally or three vertically (exclud- TOP VENT - Only a clearance to combustibles of 1" all
ing the fireplace and the air terminal connections) when around the vent pipe is required.
using aluminum flexible venting. ' REQUIRED RISE ON HORIZONTAL VENTING BCDV36 CDV36
For optimum flame appearance and fireplace perform-
ance, keep the vent length and number of elbows to a I RIGID VENTING 0 "/FT 1 "/FT*
REAR VENT
minimum. FLEXIBLEVENTING 0 "/FT 1 "/FT*
The air terminal must remain unobstructed at all times.
Examine the air terminal at /east once a year to verify RIGID VENTING 1 0 "/FT I 0 "/FT
that it is unobstructed and undamaged. TOP VENT FLEXIBLE VENTING 0 "/FT 0"/FT
Purge all gas lines with the glass door of the fireplace
CORNER
open. Assure thata continuous gas flow is at the burner RIGID VENTING 0" 6"
r
before closing the door. FLEXIBLE VENTING 6" 6"
Underextreme vent configurations, al /ow several minutes
(5- 15) for the flame to stabilize after ignition. • When a vertical rise is used as part of the venting con -
Six (6') inches is the minimum bend radius a //owed for figuration, a 0" rise per foot is acceptable.
the 7 "diameter flexible liner.