Loading...
Plans MICHAEL K. BROWN RECEIVED Registered Professional Structural Engineer In Partners with S E P 0 2 2010 `-,trir, tr,rai LrrrrnEer-, CITY OF TIGARD - .t Fide t ' 'et- `�t it, v,r l C C R E BUILDING DIVISION ,et, ENGINEERING Pi' • , ,I f' , >r ,r1III rVru i '1 t LATERAL STRUCTURAL DESIGN CALCULATIONS FOR LOT 110, ARLINGTON HEIGHTS TIGARD, OR ENGR. JOB # DM10 -050 g oolizttp • Prepared for: Lr _ .7 StoneBridge Homes, NW, LLC Plan #: 199 OTE: 1481 Date: 9-01 -2010 The following calculations are for lateral wind and seismic engineering only. Gravity loading and the design of foundations are outside the scope of this design. The design is based on information provided by the client who is solely responsible for its accuracy. The engineering represents the finished product. Discrepancies from information provided by the client invalidate this design. Core Engineering shall have no liability (expressed, or implied), with resped to the means and methods of construction workmanship or materials. Core Engineering, PLLC. shall have no obligation of liability, whether arising in contract (including warranty), Tort (including active, passive, or imputed negligence) or otherwise, for loss or use, revenue or profit, or for any other incidental or consequential damage r INSTALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER. CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS, CSA 2.33, ANSI Z21.88 FOR VENTED GAS FIREPLACE HEATERS \ f 1/ RECEIVED .. ‘,, SEP O 2 2010 ;i lit CITY OF TIGARD i BUILDING DIVISION f Ilk CONTI :;2 '- • FIREPLACES • DIRECT VENT MILLIVOLT SYSTEM INSTALLATION AND OPERATION INSTRUCTIONS FOR f NATURAL GAS MODEL CDV36NTR & BCDV36NTR PROPANE GAS MODEL CDV36PTR & BCDV36PTR CERTIFIED FOR CANADA AND UNITED STATES USING ANSI / CSA METHODS WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. FOR YOUR SAFETY Do not store or use gasoline or other flammable vapours and liquids in the vicinity of this or any other appliance. WHAT TO DO IF YOU SMELL GAS: • Do not try to light any appliance. • Immediately call your gas supplier from • Do not touch any electrical switch. a neighbour's phone. Follow the gas • Do not use any phone in your build supplier's instructions. ing. • If you cannot reach your gas supplier, call the fire department. Installation and service must be performed by a qualified installer, service agency or the gas supplier. O 9 °O1 ep Warnock Hersey luso Az. R -2000 ' , 11'rioIn us J v �+ s L 9 J 1WIOI�f�lb \BfOK1• r D�l'a \,t`Z Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4YB Canada : (705)721 -1212 • tax(705)722-6031 www.continentalfireplaces.com • ask @continentaltire.com W415-0211/ G/07.04.03 5 CDV36;. SPECIFICATIONS- BCDV36 - SPECIFICATIONS - l A MIME A Wild 35 I 35 h' 1 24 Vi ' 24 'le 33' S 'h' GAS 32 Ali 5'h' INLET I INLET 3' Ili 3' T lllli T ELECTRICAL INLET 1_27• J ELECTRICAL INLET 1 .----27' LEFT SIDE I LEFT SIDE 4' 0 I I 1 ; :_ ' —f 14' 7 D m 1 I 1 j • 1I 'h . m 12 � 12'li J Lim.," I 18 Ns" — 18•-1 -I I FIGURE la 3r I FIGURE lb 37 'le VENTING MODELS CDV36 AND BCDV36 MAY BE VENTED EITHER AS A TOP VENT OR A REAR VENT. REFER TO THE SECTION APPLICABLE TO YOUR INSTALLATION. VENTING . LENGTHS For optimum performance it is recommended that all horizontal runs have a 1 inch rise per foot when using Use only Wolf Steel or Simpson Dura -Vent Model DV -GS Wolf Steel flexible vent components. venting components. Minimum and maximum vent lengths, A terminal shall not terminate directly above a sidewalk for both horizontal and vertical installations, and air termi- or paved driveway which Is located between two sin - nal locations for either system are set out in this manual g/e family dwellings and serves both dwellings. Local and must be adhered to. For Simpson Dura -Vent, follow codes or regulations may require different clearances. F : the installation procedure provided with the venting com- D not a / /ow the inside liner to bunch up on horizontal or E ponents. vertical runs and elbows. Keep It pulled tight. A 1' -"air When using Wolf Steel venting components, use only ap- gap all around between the inner liner and outer liner is proved Wolf Steel rigid / flexible components with the fol- required for safe operation. Use a firestop when pen - lowing termination kits: WALL TERMINAL KIT GD222, or etrating interior walls, floor orcei/ing. 1/12 TO 7/12 PITCH ROOF TERMINAL KIT GD110, 8/12 TO Minimum clearance to combustible con - 12/12 ROOF TERMINAL KIT GD111, FLAT ROOF TERMI struction from fireplace and vent surfaces: NAL KIT GD112 or PERISCOPE KIT GD201 (for wall pen- etration below grade). With flexible venting, in conjunction sides, back, bottom and top of the unit 0 inch with the various terminations, use either the 5 foot vent kit recessed depth 14 inches GD220 or the 10 foot vent kit GD330. top, sides and bottom of the vent pipe* 1 inch Wolf Steel rigid and flexible venting systems must not top of the vent pipe - rear vent only* 2 inches be combined. '` REAR VENT - A clearance to combustibles of 1" at the Wolf Steel and Simpson Dura -Vent venting systems bottom of the vent and 2" at the top must be maintained must not be combined. during the first 12" of venting when penetrating combusti- These vent kits allow for either horizontal or vertical venting ble walls. The firestop spacer (W615 -044) supplied with of the fireplace. FIGURES 3 & 5. The maximum allowable the unit should be used to maintain this clearance. There - horizontal run is 20 feet. The maximum allowable vertical after a 1" clearance to combustibles may be maintained vent length is 40 feet. The maximum number of 4" vent using firestop spacer (W500- 0096). connections is two horizontally or three vertically (exclud- TOP VENT - Only a clearance to combustibles of 1" all ing the fireplace and the air terminal connections) when around the vent pipe is required. using aluminum flexible venting. ' REQUIRED RISE ON HORIZONTAL VENTING BCDV36 CDV36 For optimum flame appearance and fireplace perform- ance, keep the vent length and number of elbows to a I RIGID VENTING 0 "/FT 1 "/FT* REAR VENT minimum. FLEXIBLEVENTING 0 "/FT 1 "/FT* The air terminal must remain unobstructed at all times. Examine the air terminal at /east once a year to verify RIGID VENTING 1 0 "/FT I 0 "/FT that it is unobstructed and undamaged. TOP VENT FLEXIBLE VENTING 0 "/FT 0"/FT Purge all gas lines with the glass door of the fireplace CORNER open. Assure thata continuous gas flow is at the burner RIGID VENTING 0" 6" r before closing the door. FLEXIBLE VENTING 6" 6" Underextreme vent configurations, al /ow several minutes (5- 15) for the flame to stabilize after ignition. • When a vertical rise is used as part of the venting con - Six (6') inches is the minimum bend radius a //owed for figuration, a 0" rise per foot is acceptable. the 7 "diameter flexible liner. W415-0211 /G/07.04.03