Loading...
Permit A, :CITY OF TIGARD ELECTRICAL PERMIT PERMIT #: ELC2004 -00721 AL./Mi ‘e DEVELOPMENT SERVICES DATE ISSUED: 11/10/2004 13125 SW Hall Blvd.. Tigard. OR 97223 (503) 639 -4171 PARCEL: 1 S136AA -01500 SITE ADDRESS: 10313 SW 69TH AVE SUBDIVISION: FUR VALLEY ZONING: R -4.5 BLOCK: LOT : 006 JURISDICTION: TIG Project Description: 1- 200amp serv. and 5 branch circuits. RESIDENTIAL UNIT TEMP SRVC /FEEDERS MISCELLANEOUS 1000 SF OR LESS: 0 - 200 amp: PUMP /IRRIGATION: EACH ADD'L 500SF: 201 - 400 amp: SIGN /OUT LINE LTG: LIMITED ENERGY: 401 - 600 amp: SIGNAL/PANEL: MANF HM/ SVC/ FDR: 601 +amps - 1000 volts: MINOR LABEL (10): SERVICE /FEEDER BRANCH CIRCUITS ADD'L INSPECTIONS 0 - 200 amp: 1 W /SERVICE OR FEEDER: 5 PER INSPECTION: 201 - 400 amp: 1st W/O SRVC OR FDR: PER HOUR: 401 - 600 amp: EA ADD'L BRNCH CIRC: IN PLANT: 601 - 1000 amp: PLAN REVIEW SECTION 1000+ amp /volt: > =4 RES UNITS: > 600 VOLT NOMINAL: Reconnect only: SVC /FDR >= 225 AMPS: CLASS AREA/SPEC OCC: Owner: Contractor: LUKE -DORF TICE ELECTRIC 10313 SW 69TH PO BOX 15009 TIGARD, OR 97223 2139 SE BELMONT ST PORTLAND, OR 97293 -5009 Phone: 503 - 624 -0866 Phone: 503 - 233 -8801 Reg #: LIC 166 SUP 2586S FEES ELE 26 -126C Description Date Amount Required Inspections [ELPRMT] ELC Permit 11/10/200' $113.55 [TAX] 8% State Surcharge 11/10/200' $9.08 Rough - Elect'I Service Total $122.63 Elect'I Final This Permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable laws. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more than 180 days. ATTENTION: Oregon law requires you to follow rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952 - 001 -0010 through OAR 952 - 001 -0100. You may obtain copies of these rules or direct questions to OUNC at (503) 246 -6699 or 1 -800- 332 -2344. Issued By: /` 7 Permit Signature: OWNER INSTALLATION ONLY The installation is being made on property I own which is not intended for sale, lease, or rent. OWNER'S SIGNATURE: DATE: CONTRACTOR INSTALLATION ONLY SIGNATURE OF SUPR. ELEC'N: DATE: LICENSE NO: &S Call 639 -4175 by 7:OOpm for an inspection the next business day 11/09/2004 09:24 503 - 872 -8290 TICE ELECT.SERV.DEPT PAGE 02 11.0. 2p :33 FAX 5035981960 1 �i003 -� �1 9 • d CITY O F TIGARD Elestr�ical per A cat o; n• • I'm( t_r1' LE • FJCF. . ONLY • . City Tigard. ,,_. .. h' 8 .. , a : it 10 0 156 nrp,it u' ,1 oOi-/ -00 9,1 • :3125 SW Nall Blvd., Tigard, On 97223 '" Plea Aeviy« Phone: 50!,639,4171 Fax 503.598.1960 '•ii,t DateiB: Other Permit: ,ntpeoeon Line: 503.63: � - Q1 ', . ,a ' _AL' Al' 1 Dose /11Y: &! See rase 2 to internal www.ci,tigard or.u5 ' ' ° ,•,, tJ o - - NontletYmelh -' / od: / Sup - Weenie' lnformatinn rftPB: Olr Wolue 1 .. New const:uctlon Dk !/a)uiationtteplaaemont Please check all mar cooly: 0 Demolition _ �f Other: . .. • OSC*vlce over 223 amps, eornm'1 [Jfiaz doue location • _ DServiee ovor 32a amps - rating 0Suileng over 10,000 Al. 1. G512'EGAAY ; (3F' CWii9r Rf�CrTpN of I - and 24a/oily dwellings a or Marc new residaat:al I f ❑ 1. and 2- family dwelling ZJ Commercial/industrial d Accessory building ❑ Sys aver 600 volts nominal units in one structure °Buiilding over Over statics ❑Iroodcrs, 400 amps or more ( [l :1I'_(tl- 113ily Q Master builder ❑ QOeenpant Maid d over 99 persons Manufeetured structures or } :101 $'1TE PtFORMATIO"1. ii.ND• LOCATION : QEgressilighting RV perk QMeoith•earc facility ElOther • Job no.: 99.9259 . Job silo address- 10313 Sw 69th Ave Submit 1. sets ofplens with any of the above. . City /Stare/ZIP: The above aro not applicable to temporary construction service. Tigax'd 97223 " FMS•• 'SCItRDUlt; • • Suite/bldg. /apt:. no.: Project name: • poo.rpll Q e. r.. veal ! •• • Cross ureet/.dirattiots to job site: New residential single- or multi fancily AWeUiog uau: Includes attached garage. • 1,000 sq. t< or ku 145.15 4 • Subdivision: . )' .ot n0 : f _� wt 500 s q. it or pardon in r 33.40 1 Cox map/parcel . ?0 - J tad anew, maiden:in/ 75.00 2 , • - • . • hutted camp, non - residential 75.00 ' 1 2 • .- ' •.'DESCRIPi'ION OF WORK :' ' ' each macufiewtadormodular dwelling, tatvka and/Sr fcoder 90.90 I z . New service . - mile wiring flax . r�del • Services or feeda.a in.taUatior►, attar'tio� and/or relocation . . 200 amps or leas _ - 1 80.312 • • ` P1top 'rX OWNRR : ❑ ENAl!(T 201 amps to d00 mps a 1 a6.eJ 2 - . 401 ow t0 600 stops 160.60 1 z Name: Luidet3orf Inc, _ 601 amps to 1.000 mops 240.60 1 2 . Adereea: • 10313 SW 69th Ave • . OVA/ 1,000 raga or VOiu 454.65 . 1 2 ' Reconnoctonly 66.85 1 2 • • City/State/2V: • Tigard OR 97223 • Temporary services Of feeders lmtalladon.'lteration, and for relocation • PF.ana: ( 503) 246 - 5493 1. Fax: ( • _ 200 amps or lase 66.85 • 1 Owner humiliation: 'ibis installation i6 being made 9n'prOperty that 1 owrt which is not 1 201 amps re- 400 maps 100.30 2 mtend.d for sale, lease, rent, or exchange, according to ORS 417, 449, 670, and 701. _ W I amps to 60U amps 133.7 2 • Owner signature; ' ' Date' Brooch circuits - new. alteration, or eettasiui . per panel ❑ AP . RLICAN't 1.. • .. Q .CON[Twt'I' PYRSdN ' :, ...: A Ace 1br braacL circuits with rsr v i ee or fCC re"Cil • Business nnnte. Munch circuit 5 6 31 751 2 Cantat t' oarie: • g. Fee for branch circuits +Willow service or fee$er fee, ' 46.83 2 Address: - each batch circuit Each add'1 blonds 'circuit 1 6.65 -- 2 C :y /Start /ZIP; Miscellaneous Wavle* or reedir sot included) ... - I Phore (.. ) 1 Ft*: , ( Pump or imgatio i circle 1 53.40 ! 2 Sign or outline lighting , 53.40 2 J • E -mail: Signal cireuit(s) or limited. • • • • • : ::. CoNT.RActim .'.: •: ; energy paw a or I • " - extension, Describe: 1 Page 2 2 ' Bustncss name: Tice Electric Co. i .i3d: qs: -4. : • • • 1 1 • • E$ch additional Inspection user allowable In a oy of the abort /Z Por tland Olt' 97293 -5009 - investigation stigation (I per hour 623 City/State/Zip: IP: ••••• luvcatig.deet» 62 • ia • .50 ,,,.A. t 503 233 -8801 >tax; ( 503) 872-8290 lndustrialplantperhoar , 73.73 1 I�'6 r • .. S ." • e> X ECnt psw ,r MS* CCB Lk.: .: • Electrical Lio • 26 - 6C slam.. ti 2586$ Subtotal 113.55 � .5uprv Electrician Si gtlature, required: - . • • / Plan review (25% of permit (ee) • a • '. 1 • Sate surcharge (8%ofpctmitfoe) . 9 -Ulf Pynt ,utle. John a Malone • D ate; • TOTAL PERMIT PEE 122.63 1 Authorized signatwc; ' . op .. ..� ' /, , 1u►t permit applb Ward euplres If a permit is oni o ard wlthtn 1 VO nays atter It has bean ecceptod es comply • i Print same, John Maloney. Due 11/0q/n4 • Fly m.rsodaasay as byIfi -cew.y ewl4ing !Mussy a,.vicr Dora •• Number of inspeetlmu per penrdt showed. e.ikin -r.?"-vs. 1'an3 4'O-4bu'rrt01e7 /COSYW:S CITY OF TIGARD 24 -Hour BUILDING Inspection•tinev-(503) 639 -4175 INMION DIVISION Business Line: (503) 639 -4171 MST BUP Re gd co-L:5 5 Date Requested 9 AM PM BUP Location /6 3 3 Co 9 „ ,4 ±€ - Suite MEC Contact Person Ph ( )34 - 73.0 c PLM Contractor Ph ( ) SWR BUILDING Tenant/Owner ELC t Footing ELC Foundation Ftg Drain Access: ELR Crawl Drain Slab Inspection Notes: SIT Post & Beam Shear Anchors Ext Sheath/Shear Int Sheath/Shear / / Framing Drywall ,Ll f2saA . y/2.:1- Drywall Nailing Firewall Fire Sprinkler Fire Alarm Susp'd Ceiling Roof Other: Final - PASS PART FAIL PLUMBING 4( Post & Beam Under Slab Rough -In Water Service Sanitary Sewer Rain Drains Catch Basin / Manhole Storm Drain Shower Pan Other: Final PASS PART FAIL MECHANICAL Post & Beam Rough -In Gas Line Smoke Dampers Final PASS PART FAIL ELECTRICAL Service Rough -In UG/Slab Low Voltage f 11' L ►� Fire Alarm Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd. PART FAIL SITE LI Please call for reinspection RE: ❑ Unable to inspect — no access Fire Supply Line ADA Date i" I 1" V S Inspector \lo.'�.� I r� 6‘... i k1 N 6 Ext ■ Approach/Sidewalk Other: Final DO NOT REMOVE this inspection record f om the Job site. PASS PART FAIL