Correspondence „s oo 69
DEACON
DEVELOPMENT GROUP
RECEIVED
July 25, 2009 JUL. 2 7 7009
Dan Nelson CITY OFTIGARD
City of Tigard BUILDING DIVISION
Community Development
Building Permitting
13125 SW Hall Blvd.
Tigard OR 97223
Deacon
Development Group RE: 13333 SW 68 Parkway
Removal of ADA ramp at east courtyard
Portland Dan,
Seattle
Sacramento There is an ADA ramp shown at the east courtyard entrance on C2.2. Although
Irvine shown on the plans, we do not intend to build this ramp, but will grade and make
allowances for it in the future.
This is a secondary entrance to the ground floor. The main entrance is through the
main lobby and down the provided elevator and stairs. The egress of the building
does not require this exit. It is intended to be a secondary entrance and amenity to
any tenant who is located at the entry doors.
During our plan review on Tuesday 7/21/09, you agreed that his is not a required
accessible exit. We will not be building it in phase 1, and will only do so if the
occupying tenant wishes to have a ramp.
Attached is a revised accessibility worksheet. We are doing significant
improvements to the parking, site entry and bathrooms which currently do not meet
accessibility requirements. The deletion of this ramp still maintains a threshold of
over 25% of work to be done to remove barriers.
Please consider that the ramp is deleted from the plans or is a "future phase” during
your review.
Thank you,
ij � //
Kendra Howell
Development Manager
901 NE Glisan Street,
Suite 100
Portland, OR 97232
T: 503.297.8791
F: 503.297.8997
www.deacondevelopment.com
Barrier Removal Plan and estimate
5.20.09 TRIANGLE POINTE
Parking
Provide new raised crosswalk from front of building parking field
to building entry Note 3, C2.1 $ 11,200
Provide detectible warning, new sidewalks and accessible
parking at new entry Note 6, A2.1 $ 6,500
Provide detectible warning and accessible parking at garden
level entry Note 6, A2.1 $ 540
Restripe Parking for ADA compatibility $ 3,500
$ 21,740
A ccessible Entrance
Provide accessible stairs to main entry Note 8, C2.1 $ 15,000
Provide accessible ramp to main entry including handrails Note 17, C2.1 $ 12,500
New metal pipe handrail at existing stair Note 20, C2.1 $ 1,000
Remove exist. Vestibue (did not meet min depth $ 18,000
New Door 101 A w/ new hardware /threshhold 2/A8.2 $ 3,500
$ 50,000
A ccessible Route to Altered Area
New doors and hardware in altered area, 103A, 105A, 109A,
110A, 111A Sched A9.1 $ 5,000
Compliant elevator call buttons $ 1,200
$ 6,200
Accessible Restrooms
Current restroom are not ADA compliant in heights, clearances,
etc. Restrooms will be redesigned and expanded for
compliance. A5.7 $ 60,000
$ 60,000
Accessible Telephones
n /a, not provided
Accessible Drinking Fountains
I n /a not provided
Accessible elements such as storage and alarms
n/a not provided
'TOTAL: $ 137,940
estimated improvements, not including OH /fee $ 500,000
28%
Dan Nelson
From: Scott Moore
[SMoore @grpmack.co
m]
Sent: Tuesday, July 21,
2009 5:11 PM
To: Dan Nelson
Cc: Kendra Howell
Subject: Triangle Pointe Lobby
fire rating
Attachments: printersupport@grpm
ack.com_20090721_
153107. pdf
Dan,
I did some more looking into the fire rating
requirement within the main lobby space and I
believe that the code may allow for provisions that
do not require we rate the construction of the walls
internal to the lobby enclosure (ie toilet rooms,
janitors room, electrical room, etc). I have
attached a copy of the 2006 IBC Commentary,
apparently our office does not have a copy of the
2007 OSSC Commentary, but in looking at
previous versions it appears the same response
was given to this sections, so my assumption is
that it has not changed. This section states that
"The lobby, all other areas on the same level that
are not separated from the lobby by fire barriers
consistent with the rating of the stair enclosure,
must be sprinklered in accordance with NFPA 13.
If the entire level is sprinklered, no separation is
required ". There is a requirement that the
lobby floor and supporting construction must be
rated the same as the stairway enclosure to
prevent a fire from mitigating up to the lobby from
the floor below.
believe that this clause allows us to construct all
the new walls and doors for the toilet rooms and
other incidental spaces within the lobby as non-
rated construction as long as we provide sprinklers
throughout these spaces, which is what I believe
we are doing anyway. Beyond the lobby area in
question we would provide a 2hr separation
between the office space and the lobby. At that
point, only the stairway enclosure walls and door,
elevator and mechanical shaft walls, and the wall,
door and relight separating the lobby from the rest
of the office space would need to conform to 2 hr
construction. Doors within these walls would
1
be 90 minute doors. This appears to match what
we proposed on our initial plan that was submitted.
I think then we'd just need to confirm the rated
assembly of the existing 2hr walls,confirm that the
concrete floor thickness achieves the 2hr rating
and make sure that all penentrations in the floor
are properly equipped with fire and smoke
dampers as needed.
I'm working on the wall assembly portion of this,
and will try and get something to you by tomorrow
morning.
Let me know what you think.
Thanks,
Scott
GROUP
MACKENZIE
RiverEast Center 1 1515 SE Water Avenue, Suite
100 1 Portland, OR 97214
P.O. Box 14310 1 Portland, OR 97293
T: 503.224.9560 1 F: 503.228.1285
www.groupmackenzie.com 1 vCard
PORTLAND, OREGON !SEATTLE,
WASHINGTON 1 VANCOUVER, WASHINGTON
Please consider the environment before
printing this email. Thank you.