Loading...
Correspondence • 21SO Wit TTf FAILS De Wf51 Ukk. OREGON 41468 sus 6.1194% FAX 50165591/8 July 14, 199R Mr. FA Edinger Environomics c/o Farmers Insurance 13333 S. W. 68i Parkway V114110 Tigard, OR 97223 —MI — RE: Roof Sampling and Analysis for Fire Ratings SSO(IAT. ULM= insurance, 13333 S. w. 6r Pgd_way, Tigard. S?B 111t04P0U1O Ucar Mr. Edinger: INDEPENDENT On 't'hursda Jul 9m, we physically sampled the existing roof on Farmers F O R ROOF Y. Y P Y Y r FOR ROOFING Insurance to determine the composition of the total assembly for the purpose of AND RELATED establishing/verifying the tire rating of the assembly. TRADES Our examination revealed that the roof and insulation assembly was installed ovcr a steel fluted deck. The roofing consists of 2'/2' Polite, 3i4" Fiberglass ANALYSIS insulation. 3 - ply of huilt •up roofing and gravel. The rating classification of the • Farmers Insurance building is a class A fire rating. TEsTINC i f you have any questions or if we can he of ftuthcr assistance, please don't hesitate to call. CORRECTIVE ACTION Sincerely, LUNG TERM ROOF MANAr,EMIMT C1/1 414 ANNING Ron Peterson SPECIFICATIONS ANO Field Service Representative URAWiNGS • ON•SITt rROJLCr MANAGtMENT • LITIGATION IaANAIai NMMuNe1 114Canloien MIN (ruaane Z9 "d 98S£9SI We' LI:oI 86- vt -lflf _.. . , . . F RIjD , $HI3ARIR ._ 60,0,s-_„ 2_9 c(, C'S ONS, INC. CONTRACTOR Established 1916 July 21, 1998 City of Tigard Building Department 13125 SW Hall Blvd Tigard, OR 97223 Attn: Jim Funk Re: Farmers Insurance Building Y33 33 zW 6 5rt P4,.kunLy Tigard, OR 97223 Dear Mr. Funk: We are submitting an application for a building permit to re -spray a portion of the roof beams and metal deck with W.R. Grace Co. Retro Guard direct to steel fireproofing. Fireproofing to be replaced where the original has been abated by AC & S Company, on the 4 floor plus on the metal deck which was not previously fireproofed, in the same area. The area involved is described on the floor plan as Cafeteria 406, Dishwash 407, Storage 415, Serving 416, Office 417, Work Room 418, Typewriter 419, Passage 425, Storage 414, and Lobby 411. Portions of these areas have been protected originally with metal lath and plaster and were \ not disturbed and will not be sprayed. v We have based the thicknesses of the fireproofing on Building Type II, one hour, not sprinkled, requires one -hour d metal k The roof >" � � covering per your was tested direction. by This Schaber and Associates and protection the on test results roof beams show an the insulation dec. type to be a mineral fiber board of 2 -1/2" Perlite and binders with 3/4" fiberglass and 3 ply built up roofing \ and gravel. This meets the criteria for UL Design P 740. Therefore, we have figured the following thicknesses. Roof Deck 1-1/4" Roof Beams 12 B16.5 = W 12 x 16 = 11/16" 12WF27 =W 12x26 =5/8" 12WF36 =W 12x35= 9/16" 16 B26 = W 16 x 26 = 5/8" 16WF40 =W 16x40 =9/16" 16 WF58 = W 16 x 57 = 7/16" Tapered girders have a W/D ratio of .513, which requires a thickness of 11/16 ". FIN #93- 0591480 CCB #357 7000 S.W. Varns St., Tigard, Oregon 97223 Telephone: (503) 639 -2499 Fax: (503) 684 -4069 PR re-i SHEARER ('S oNs , INC. CONTRACTOR Established 1916 Page 2 City of Tigard Building Department Farmers Insurance Bldg. The enclosed plan has been marked with these thicknesses written next to the beams. Also, copies of pages 1, 2, 3, and 4 of the required thickness guide for UL Test #P740 for W.R. Grace Company's material thickness handbook, dated 1997 are enclosed. The total value of this permit is $40,414.00. Testing of the fireproofing will be by an independent laboratory and not part of our contract or this permit. Your assistance in the issuance of this permit is appreciated. .'n•-rely, F'. D SHEA R SONS C. Ji an Horn SAM FIN #93- 0591480 CCB #357 7000 S.W. Varns St., Tigard, Oregon 97223 Telephone: (503) 639 -2499 Fax: (503) 684 -4069