Plans Health Net 11 January 11, 2006 Twig Data - Variable Air Volume Single Duct Terminal Units (Qty: 3) Item Tag(s) Qty Description Model Number Al VAV -1 -8, VAV -2 -8 2 Variable Air Volume Single Duct Termina VCEF08 A2 _ VAV -14 1 Variable Air Volume Single Duct Termina VCEF14 Product Data - Variable Air Volume Single Duct Terminal Units RECEIVED All Units Single duct with electric heat Matte faced insulation - 1/2" 'jAN 17 2006 DDC, controls on /off electric heat control Standard actuator CITY OF TIGARD Left hand & /or same side connection BUILDING DNISION 480/24 volt transformer Disconnect switch Power Fuse 480 volt, 3 phase Magnetic contactors - 24 volt 1st year parts and labor limited warranty Item: Al Qty: 2 Tag(s): VAV -1 -8, VAV -2 -8 /77 G c0 � 8" inlet size, 720 cfm �.J Electric heater kW - 5.0 Stage -1 Item: A2 Qty: 1 Tag(s): VAV - 14 14" inlet size, 3000 cfm Electric heater kW - 7.5 Stages - 2 - equal Performance Data - Variable Air Volume Single Duct Terminal Units Tags VAV -1-8, 2-8 VAV -14 Design cooling airflow (cfm) 720 2400 Min cooling airflow (cfm) 380 640 Valve heating airflow (cfm) 380 640 • Cooling inlet diameter 8" 14" APD @ cooling airflow (in 0.07 0.01 H2O) Discharge valve - 125 Hz (dB) 63 70 Discharge valve - 250 Hz (dB) 57 66 Discharge valve - 500 Hz (dB) 54 65 Discharge valve - 1 kHz (dB) 50 58 Discharge valve - 2 kHz (dB) 47 58 Discharge valve - 4 kHz (dB) 51 59 Discharge valve - NC () 15 24 Radiated valve - 125 Hz (dB) 58 68 Radiated valve - 250 Hz (dB) 52 64 Radiated valve - 500 Hz (dB) 49 56 Radiated valve - 1 kHz (dB) 44 50 Radiated valve - 2 kHz (dB) 46 45 Radiated valve - 4 kHz (dB) 42 43 Radiated valve - NC () 23 35 Full load amps (A) 6.01 9.02 Min circuit ampacity (A) 7.52 11.28 Max fuse size (A) 15.00 15.00 Operating weight (lb) 38.0 60.0 " 6.- Primary EDB (F) 55.00 55.00 = Unit LAT (F) 96.41 91.88 Electric heat kW (kW) 5.00 7.50 FLD = Fumished by Trane / Installed by Others Trane Equipment Submittal Page 3 of 10 • HealthNet 11 January 11, 2006 •'` Mebhanical Specifications - Variable Air Volume Single Duct Terminal Units Item: Al, A2 City: 3 Tag(s): VAV -1-8, VAV -2-8, VAV -14 General Unit Information The unit casing is comprised of 22 gauge galvanized steel. Outlet connection is slip and drive. Agency Listing - The unit is UL and Canadian UL listed as a room air terminal unit. UL Control # 9N65. All Trane terminal units are ARI 880 - 98 certified. General Unit Clearance Allow adequate clearance to meet NEC on control box side of unit to meet NEC. A minimum of one and one half duct diameters of straight duct work, upstream of the air inlet connection, should be present for optimum airflow measurement performance. Upstream duct work should be the same diameter as the primary inlet connection. 1/2" Matte - Faced Insulation The interior surface of the unit casing, is acoustically and thermally lined with 1/2" 1.50 Ib.cu. ft. [24.00 kg. /cu. m.] composite density glass fiber with 4.0 Ib. cu.ft. [64 kg. /cu. m.] high density facing. The insulation is UL listed and meets NFPA -90A and UL 181 standards. The insulation R -value is 1.9. All cut edges of insulation are completely encapsulated in metal to prevent erosion. Air Valve Round The air inlet connection is an 18 gauge galvanized steel cylinder sized to fit standard round duct. A multiple point, averaging flow sensing ring is provided with balancing taps for measuring within +/- 5% of unit cataloged airflow. An airflow versus pressure differential calibration chart is provided. The damper blade is constructed of a closed cell foam seal mechanically locked between two 22 gauge galvanized steel disks. The damper blade assembly is connected to a cast zinc shaft supported by self lubricating bearings. The shaft is cast with a damper position indicator. The valve assembly includes a mechanical stop to prevent over stroking. At 4.0" w.g. air valve leakage does not exceed 1% of cataloged airflow. Air Valve Size - 08 Air Valve is 900 cfm [425 Vs] 8" inlet. Air Valve Size -14 Air Valve is 3000 cfm [1416 Us] 14" inlet. Electric Heat Coll Factory provided and mounted, UL recognized, resistance open -type heater with airflow switch, a disc -type automatic pilot duty thermal primary cutoff, and manual reset load carrying thermal secondary device. Heater element material is nickel- chromium. The heater terminal box is provided with 7/8" knockouts for customer power supply. Terminal connections are plated steel with ceramic insulators. Heater control access is left hand. Right hand control access is optional. Magnetic Contactor An electric heater 24 volt contact for use with Direct Digital Control (D.D.C.) or Analog Electronic VAV Controls. Power Disconnect Switch (for VCEF) A factory provided interlocking door disconnect switch located on the electric heater control panel. Line Fuse A safety fuse located in the electric heater's line of power to prevent power surge damage to the electric heater for VCEF. For VCCF and VCWF, the fuse is installed on the primary voltage hot leg in a control box. Slip & Drive Connection A slip and drive connection has two straight flanges on the top and bottom, and two drive connections on the left and right sides. This is a standard option on all VAV single duct terminal units. Electric Heat Transformer A 40VA or 75VA transformer will be an integral component of the heater control panel dependent on unit load requirements to provide 24 VAC for controls. D.D.C. Actuator Trane 3 wire, 26 GA, 3.4 VA, 1.7 W, 24 VAC, 50/60 Hz floating point control actuator with linkage release button. Running torque is 35 in-lb (4 Nm) minimum and is non - spring return with a 90 second drive time. Travel is terminated by end stops at fully opened and closed positions. An integral magnetic clutch eliminates motor stall. When Trane FLD = Furnished by Trane / Installed by Others Trane Equipment Submittal Page 4 of 10 , HealthNfet TI January 11, 2006 controls are not provided an integral 3 screW terminal is provided for field wiring. Operating temperature is 32 to 125 degrees Fahrenheit (0 to 50 degrees Celsius). Direct Digital Controller The microprocessor based terminal unit controller provides accurate, pressure independent control through the use of a proportional integral control algorithm and direct digital control technology. The controller monitors zone temperature set points, zone temperature and its rate of change, and valve airflow using a differential pressure signal. Optionally, the controller can monitor either supply duct air temperature or CO2 concentration via appropriate sensors. The controller is provided in an enclosure with 7/8" knockouts for remote control wiring. A Trane zone sensor is required. System Communications The controller is designed to send and receive data from a Tracer Summit or other Trane Controllers, or a Varitrac Central Control Panel. Current unit status conditions and set points may be monitored and/or edited via this data communication feature. The network type is a twisted wire pair serial communication. Override Commands The following override commands may be received by the Unit Control Module (U.C.M.) from the Tracer System. Control Mode, Action, Offset & Commands * Control Mode - Occupied or Unoccupied * Control Action - Heating or Cooling * Control Offset - Enabling Control Offset will increase the cooling temperature setpoint and decrease the heating temperature setpoint by a control offset value. * Drive damper fully open. * Drive damper fully closed. * Drive damper to maximum airflow setpoint. * Drive damper to minimum airflow setpoint. * Disable unit heat. * Reset - Enabling the reset function forces the controller and the flow sensor to recalibrate. Editable Set points and Functions Occupied and unoccupied cooling temperature set point (30 °- 100°F) [ -1.1 °- 37.8°C] Occupied and unoccupied heating temperature set point (30 °- 100°F) [-1.1°- 37.8°C] Maximum flow set point (10- 100% of unit equivalent cataloged airflow) Minimum heating and cooling flow set point (0, 10- 100% of unit equivalent cataloged airflow) Cooling set point low and high limit Low (30 °- 100°F) [ -1.1 °- 37.8°C] High (30 °- 102°F) [ -1.1 °- 37.8°C] Heating set point high and low limit (30 °- 100°F) [-1.1°- 37.8°C] Hot water valve drive time Air valve drive time Fan Control Offset - determines at what point a parallel fan is energized. This can be a function of temperature (degrees above heating set point) or primary airflow Series Fan Configuration - allows series fan powered to shut off fan and close air valve when unit is unoccupied. Fan will operate in unoccupied mode if reheat is active. Local heating flow set point enable /disable and set point Analog input mode - auxiliary temperature sensor or CO2 detector Binary input mode - generic or occupancy detector Zone temperature, auxiliary temperature, and zone set point calibration corrections (± 10 ° F) [± -12°C] Flow measurement calibration correction (60- 150 %) Additional Status Information Available Active cooling set point Active heating set point Current unit primary airflow Current zone temperature Reheat status (on /off) Fan status (on /off) Calibration status (calibrating/not calibrating) FLD = Furnished by Trane / Installed by Others Trane Equipment Submittal Page 5 of 10 • Healthitlet 11 January 11, 2006 Auxiliary air temperature (if unit has auxiliary temperature sensor) Not available if CO2 sensor used. CO2 concentration (if unit has CO2 sensor) Not available if auxiliary temperature sensor used. Ventilation ratio BIP state Failure indicators • Temperature sensor failures • Flow Sensor failure Local zone sensor set point failure 1 DDC Sequence of Operation The unit controller continuously monitors the zone temperature against its set point and varies the primary airflow as required to meet zone set points. Airflow is limited by minimum and maximum airflow set points. DDC Controls Option DD04 Basic Operation: On /Off Staged Electric Heat (Normally Open Outputs) (DDC /UCM) A voltage signal from the zone sensor indicates the zone temperature is used by the unit controller to determine an error from the set point. This error, as well as primary flow differential pressure, is used to determine damper position within minimum and maximum cooling airflow set points. As the zone temperature drops to the heating set point, primary airflow is controlled to minimum heating flow set point. Staged electric heat is energized. FLD = Furnished by Trane / Installed by Others Trane Equipment Submittal Page 6 of 10 Healthhiet 11 January 11, 2006 Unit Dimensions - Variable Air Volume Single Diict Terminal Units Item: Al Qty: 2 Tag(s): VAV -1 -8, VAV -2-8 2 1/4" r -4 5 1/2" ► CONTROL BOX 6 1 1111 1 CONTROLS AREA V ACTUATOR II AIR FLOW \ I • I 43 1/2 1 Customer Notes 1. Air Inlet is centered in unit front panel. 2. Slip 8 Drive discharge outlet on heater standard. 3. Mow 48' of straight duct downstream 5 1/2' ► of unit before first nmoul 8 inside of the duct should be equal discharge size. (AxB) SLIP 8 DRIVE TOP VIEW 121/2. CONNECTION 4. For electric heater access, side hinged must haiimdistance per NEC or beat code. 5. Knockouts for power supply provided in top 8 bottom of terminal box. 6. Coils are provided without Internal Insulation. If the unit is to be installed in a location with high humidity, external insulation 11" around the heating coil should be Installed as required. . ,TT i 10' 1112' 8 1 4" Approximate Dry Weight 38.0 lb Weights reflected may vary BACK VIEW ±5.0 lb based upon options selected. FLD = Furnished by Trane / Installed by Others Trans Equipment Submittal Page 7 of 10 Healthftet Tl January 11, 2006 Unit Dimensions - Variable Air Volume Single Duct Terminal Units Item: A2 Qty: 1 Tag(s): VAV -14 3 1/4' 14' a 1/2"-0 ELECTRIC HEATER CONTROLS AREA CONTROL BOX\ 41111 6 1/2' ACTUATOR fill 0 431/Y • ♦� Customer Notes 1. Jr A Inlet is centered in unit front panel. 2. Slip & Drive discharge outlet on heater • 44 vrc standard. SLIP & DRIVE 3. Allow 48' of straight duct downstream CONNECTION of unit before first runout & Inside of the duct should be equal discharge size. (AxB) TOP VIEW 20 1/2" a. 4. For electric heater access, side = hinged door must have minimum distance per NEC or local code. 25' 5. Knockouts for power supply provided F7-- in top & bottom of terminal box. 19' 1 6. Coils are provided without intemal insulation. If the unit is to be installed in a location with high humidity, external insulation around the heating cog should be installed as A required. 81/4• 18' 191/2' b Approximate Dry Weight 60.0Ib _ _ Weights reflected may vary ±5.0 lb based upon options y selected. BACK VIEW FLD a Furnished by Trane / Installed by Others Trane Equipment Submittal Page 8 of 10 HealthNet 11 January 11, 2006 Field Wiring - Variable Air Volume Single Duct Terminal Units Item: Al, A2 City: 3 Tag(s): VAV -1-8, VAV -2 -8, VAV -14 HEATER STAGE 24VAC 60HZ CONTACTOR(S) NEC CLASS -2 S Q OPTIONAL CONTROL CIRCUIT • TRANSFORMER LOAD =12VA TB3-2 i` C5 (zt�o� I 1 1 (WITHOUT HEAT) 163.1 ' Te33 `/ '= ' I ��1 � \ 761-2 1 1 1 7825 1 1 1 1 I TB111 1 1 1 1 1 725 1 1 1 1 1 1 I g a g 666666 2 `.1. - 181 Tel TB3 a > o 5 e I° DIGITAL ZONE SENSOR OPTIONAL FIELD INSTALLED DIGITAL ZONE SENSOR 1 I TB24 T83-1 I T825 T83-2 I 1 1 1 7833 I 1 I r 11 J ee4b 6 1 4 5 4 3 2 1 r- o I --, ZONE SENSOR 'L_ Pi'a S� ..J A (O O ACT O O I' in i� REMOTE REMOTE ll....11 91L.. SIP GND 24V ADDRESS D.D.C. \U.C.M. OPTIONAL FIELD J3 SWITCH CONTROL BOARD INSTALLED ZONE SENSOR 2 888888 - _ 11 5 , (IB1 -I)24V 24V y - ) 'in i0 0 0 'O0 in in a CI ° w S ENSOR 24V _(?1356) GND /��j' 4 irTI Z ONE GND SET MCO2 GND OUT V _2 ,_J_, II II OPTIONAL FIELD INSTALLED / / / 1 1 1 1 CO2 SENSOR 1 1 I I TB35 - i r ,B}6 al al �I W I mo ) SHIELDED TWISTED PAIR COMMUNICATIONS WIRING OPTIONAL FIELD INSTALLED AUXTEMP SENSOR • . ; ' •11 - - - ITB1- 1124550 • I_ - (784.1)815 s � 1 I �-� 1 - 0.91.112A/AG 0.91.112A/AG � BN IRETURIq_ - 0131-2) ONO - - - - NOT CONNECTED OPTIONAL FIELD INSTALLED OCCUPANCY SENSOR WARNING HAZARDOUS VOLTAGE! DISCONNECT ALL ELECTRIC POWER INCLUDING REMOTE DISCONNECTS BEFORE SERVICING. FAILURE TO DISCONNECT POWER BEFORE SERVICING CAN CAUSE SEVERE PERSONAL INJURY OR DEATH. 8 CAUTION Customer Notes: USE COPPER CONDUCTORS ONLYI UNIT TERMINALS ARE NOT DESIGNED TO ACCEPT OTHER TYPES OF 1. Factory Installed. CONDUCTORS. - Installed by others. FAILURE TO DO 50 MAY CAUSE DAMAGE TO THE EQUIPMENT. • FLD = Fumished by Trane / Installed by Others Trane Equipment Submittal Page 9 of 10 , HealthNet 71 January 11, 2006 Fieitl Wiring - Variable Air Volume Single Duct Terminal Units Item: A 1, A2 Qty: 3 Tag(s): VAV -1 -8, VAV -2 -8, VAV -14 t 480 Volt, 3 Phase L3 L2 LI N 1 I I I I I I I I I I I I I I Heater Controls Wiring FLD = Furnished by Trane / Installed by Others Trane Equipment Submittal Page 10 of 10