Specifications E314 Pa007 - 000 SIEMENS Fire Safety HFPO -11 Intelligent Smoke Detector Intelligent Smoke Detector for FS -250 Control Panels ENGINEER AND ARCHITECT SPECIFICATIONS Model HFP(,- . . • Polarity Insensitive with SureWireTM Technology • Pre -Alarm reporting based on fire profile selected _ - - • Remote sensitivity measurement capability • Detectors are self- testing, completing diagnostics _ _ every 4 seconds • • Field cleanable chamber with replaceable chamber parts available • Multi -color detector status LED 1 �` • Low Profile Design • Two -wire operation HFPO - 11 • Compatible Model DPU field device (Shown with DB - 11 Base) programmer /tester unit • Supports software based automatic environmental compensation • Optional fully programmable relay base, audible base, and duct housing • CI Listed Introduction Description The Siemens BuildingTechnologies, Fire Safety Division The HFPO -11 is a plug -in, two -wire, photoelectric smoke HFP -11 Intelligent Fire Detector provides the life safety detector and is compatible with the FS -250 control panel. industry with the most reliable detection system available Each detector consists of a dust resistant, field - cleanable today. The HFPO -11 uses state -of- the-art microprocessor photoelectric chamber and microprocessor based elec- circuitry with error check, detector self - diagnostics and tronics with a low- profile plastic housing.The HFPO -11 supervision programs. utilizes state -of - the -art ASIC circuitry and surface mount technology for maximum reliability. Every HFPO -11 The HFPO -11 intelligent fire detector is compatible with detector is shipped with a protective dust cover.The the Fire Safety Model DPU field device programmer/ HFPO -11 detector utilizes an infrared light emitting diode tester unit, which is a compact, portable, menu - driven (IRLED), and light sensing photodiode. Under normal accessory for electronically programming and testing conditions, light transmitted by the LED is directed away detectors, easily and reliably.The DPU eliminates the from the photodiode and scattered through the smoke need for cumbersome, unreliable mechanical program- chamber in a controlled pattern.The smoke chamber is ming methods, such as dials or switches and reduces designed to manage light dissipation and extraneous installation and service costs by electronically program- reflections from dust particles or other non -smoke ming and testing the detector prior to installation. The airborne contaminants in such a way as to maintain HFPO -11 fire detector is compatible with the FS -250 stable, consistent detector operation. When smoke control panel. enters the detector chamber, light emitted from the IRLED is scattered by the smoke particles and is • received by the photodiode. CATALOG NUMBER 4309 A Communications within the detector itself and between manual stations, HTRI series interfaces, HCP output the HFPO -11 and the control panel, or with the DPU field control devices, or HZM series of addressable, conven- device programmer/tester unit, are supervised and safe- tional zone modules. All HFPO -11 detectors can be guarded against disruption by reliable, microprocessor cleaned in the field, when required, by simply removing based error checking routines. Additionally, the micro- the detector cover and unsnapping the photo chamber. processor supervises all EEPROM memory locations and There is also the option of cleaning the interior of the provides a high degree of EEPROM failure fault tolerance. detector with a clean, soft cloth or brush, or replacing The HFPO -11 determines its operating status to be the labyrinth and bug screen included in the detector normal, in alarm, or in trouble depending on the difference maintenance kit, model DMK -11. between the alarm threshold values stored in the The HFPO -11 uses the low- profile surface mounting base, detector's memory and the detector's latest analog model DB- 11.This base mounts on a 4 -inch octagon, measurement.The detector then communicates changes square, or a single gang electrical box.The base utilizes in its status to the control panel. In addition, the FS -250 screw clamp contacts for electrical connections and self - control panel will sample the value of the HFPO -11's wiping contacts for increased reliability.The base can be analog signal over a period of time in order to determine used with the optional LK -11 detector locking kit which if those values indicate excessive buildup in the photo contains 50 detector locks and an installation tool, to chamber; if so, the FS -250 control panel will indicate that prevent unauthorized removal of the detector head.The the particular detector requires maintenance. DB -11 base has integral decorative plugs to cover the The HFPO -11 is listed as a self- testing device.The outer mounting screw holes. All HFPO -11 detectors are HFPO -11's visible light emitting diode (LED) flashes approved for operation within the UL specified tempera - green every 4 seconds to indicate it is communicating ture range of 32 to 100 degrees F (0 to 38 degrees C). with the control panel and that it has passed its internal self -test. Should the detector sense a fault or.failure Application Data within its systems, the LED will flash amber and the Installation of the HFPO -11 series of detectors requires a detector.will.transmit that information to the control panel. two -wire circuit. In many retrofit cases, existing wiring A quick visual inspection is sufficient to indicate the may be used. "T- tapping" is permitted only for Style 4 condition of the detector at any time. If more detailed (Class B) wiring. The HFPO -11 is polarity insensitive. This information is required, a printed report can be provided feature can greatly reduce installation an debugging time. from.the FS 250 panel indicating the status and settings HFPO -11 detectors can be applied within the maximum assigned to each individual detector. When the HFPO -11 30 foot center spacing (900 sq. ft. areas) as referenced in moves to the alarm mode, it will flash red and to con- NFPA 72.This applications guideline is based on ideal tinue flashing until the system is reset at the control conditions, specifically, smooth ceiling surfaces, minimal panel. At that same time, any user defined system alarm air movement, and no physical obstructions between functions programmed into the system are activated. potential fire sources and the detector. Do not mount Detector sensitivity, calibration, and identification detectors in close proximity to ventilation or heating and are dynamically supervised by the control panel. air conditioning outlets. Exposed joints or beamed The DPU Device Program/Test Unit accessory is used to ceilings may also affect safe spacing limitations for program and verify the detector's address.The technician detectors. Should questions arise regarding detector selects the accessory's program mode to enter the placement, observe NFPA 72 guidelines. Good fire desired address.The DPU automatically sets and verifies protection system engineering and common sense the address and tests the detector.The DPU operates on dictate how and when fire detectors are installed and AC power or rechargeable batteries, providing flexibility used. Contact your local Siemens Fire Safety distributor and convenience in programming and testing equipment or sales office whenever you need assistance applying almost anywhere. FirePrint in unusual applications. Be sure to follow NFPA guidelines and UL approved installation • When in the test mode, the DPU will perform a series of instructions, which are included with every Siemens diagnostic tests without altering the address or other Fire Safety detector, and local codes as for all fire stored data, allowing technicians to determine if the protection equipment. detector is operating properly.The HFPO -11 detector may be installed on the same initiating circuit with HMS series p Dimensions 6" Dia. / 3/� / IF ' 1 1 rz' Va nA ,\ _ 11 2/W I . I 2 3/4' Di J 4 1/8' Dia. NOTE: The new DB-11E base has a diameter dimension of 4 1/2 inches. • Ordering Information Part Model Description Number 3 HFP0-11 Addressable Detector 500-034800 DB -11 Detector Mounting Base for Series 11 500-094151 DB -11E Detector Base (small) 500-094151E AD-11P Air Duct Housing for Series 11 500-095658 AD-HR Air Duct Housing w /Relay for H-Series 500m3280 Intelfgent Detector DB -HR Relay Base for H -Series Intelligent Detectors 500-033220 ADBH -11 Audible base 500433210 RL-HC Remote (red) alarm indicator - 4' octagon box mount 500-033230 RL- -HW Remote (red) alarm indicator- single gang box mount 500-033310 LK -11 Base Locking Kit for Series 11 detectors 500695350 DMK -11 Series 11 Maint Kg (replacement labyrinth and bug 500. 695338 bug screen) • • • • NOTICE: The use of other than Fire Safety detectors and bases with Fire Safety equipment will be considered a misapplication of Fire Safety equipment and as such void all warranties either expressed or implied with regard to loss, damage, liabilities and/or service problems. Fire Safety Fire Safety 8 Fernwood Road 2 Kenview Boulevard Florham Park. NJ 07932 3/04 Brampton. Ontario Siemens Building Technologies Tel: (973) 593 -2600 5M Canada L6T 5E4 9 9 FAX: (973) 593-6670 SFS-IG Tel: (905) 799 -9937 March2004 Fire Safety Website: www.sbt.siemens.com /fis Printed in U.S.A. FAX: (905) 799 -9858 supersedes thee: awed 7/03 • SIEMENS Fire Safety DT -1358, DT -135F DT -2008, DT -200F • Thermal Fire Detectors ENGINEER AND ARCHITECT SPECIFICATIONS • ® Listed cr • • FM Approved Introduction Rate -of -Rise Principle of Operation: The Siemens BuildingTechnologies, Fire Safety Division The rate -of -rise element consists of an air chamber, a Thermal Fire Detectors are fixed temperature or combina- flexible metal diaphragm and a moisture-proof, trouble - tion fixed temperature rate-of -rise type.The combination free vent which is carefully calibrated. detectors consist of two independently operated thermal elements.The rate-of -rise element is self- restoring. It is well known that air expands as it is heated, and con - However, the fixed temperature is of the non - restoring tracts as it is cooled. For normal, day -to-day fluctuations type of temperature, the expansion and contraction of the air within the chamber is automatically compensated by the Underwriter's Laboratories, Inc., recommends the "breathing" action of the vent. combination type thermal detector be used to protect a maximum of 2,500 square feet, and the fixed temperature However, when a fire occurs, air temperatures rise very type be used to protect a maximum of 625 square feet. rapidly and the air in the chamber expands faster than it Job conditions and engineering judgment, however, often can be vented.This creates a pressure which distends dictate closer spacing to provide faster detection. the diaphragm and closes electrical contacts. Mounting Data 9 /,8" tie" 1 49/,s " ---1 J 4 JUNCTION BOX MOUNTING SURFACE MOUNTING CATALOG NUMBER 6130 The rate -of -rise action is not related to any fixed tempera- Installation ture level, but responds with the utmost promptness • Each detector includes a thermoplastic reversible mount- when the rate of temperature rise exceeds 15° per ing plate. In one position it easily attaches to a 4" octagon minute. If the heat is removed, the air within the chamber junction box, 3 " octagon box or plaster ring. contracts and the switch moves to a normally open circuit position. In reverse, the plate can be used for open wiring without a junction box. A'1 space between detector and • mounting surface allows for wire connections. All mount - Fixed Temperature ing screws are concealed. Principle of Operation The detector simply attaches to the mounting plate with a In a slow developing fire, the temperature may not push and twist motion. No tools required. increase rapidly enough to operate a rate-of -rise element. In cases such as described a fixed temperature principle Engineer and Architect Specifications of operation is desired. The thermal fire detector shall be a Fire Safety The detector utilizes a fixed temperature element made Model (insert number). It shall operate at a of fusible alloy and is of the non-restorable type. temperature of degrees F (insert temperature).The detectors shall be listed by Underwriters' Laboratories, The fusible alloy will melt and activate the detector when Inc., and Factory Mutual for use with Siemens Building the surrounding air rises above the preset level of 135 °F Technologies, Fire Safety Division systems. or 200°F. The external heat collector drops away when the detector is activated therefore giving a quick visual confirmation that the detector has alarmed. Ordering Information Model Number DT-135R DT-200R DT-135F 4 DT-200F Description Rate -of -rise and fixed Rate -of -rise and fixed Fixed temperature Fixed temperature temperature 135°F temperature 200°F only, 135 F only, 200°F Normal temperature Normal temperature Unusually violent Unusually violent fluctuations and ceiling fluctuations and ceiling temperature fluctue- temperature fluctua- Applications temperatures not temperatures exceed- tions and ceiling tions and ceiling exceeding 100 °F ing 100 °F but not 150 °F temperatures not temperatures exceed - exceeding 100 °F ing 100 °F but not 150 °F Identification on O O Heat Collector , 0 0 NONE GRAY RING GRAY SPOT GRAY SPOT AND RING Fire Safety Fire Safety 8 Fenwwod Road 2 Kenview Boulevard Florham Park, NJ 07932 11/02 Brampton, Ontario Siemens Building Technologies Tel: torn Canada L6T 5E4 g F AX (973) (973) 5 -2600 670 SFSIG Tel: (905) 799-9937 November 2002 Fire Safety Website: www.sbt.siemens.comffis Printed in U.S.A FAX (905) 799-9858 supersedes meek dated aoo SIEMENS Fire Safety Adapter Stand Alone Selectable Strobe ENGINEER AND ARCHITECT SPECIFICATIONS • The Adapter feature offers four field selectable �! candela strobe values - 15/75, 30/75, 75 or 110 AGENT RELEASE for ceiling and wall mount _- - -, • Operates in either sync or non -sync mode 5 j • Low current draw • Integral universal mounting - single gang, AGENT RELEASE r double gang or 4" square box • Colors- red or off -white Agent Release Strobe • ADA/NFPA/ANSI compliant FIRE • 0 UL 1971 listed for both wall and ceiling mount -CSFM, FM and ULC Listed s • Made in U.S.A., ISO 9001 certified z i F • A Dual Sync Control Module or PAD -3 is only -- 1 R required to activate the Instant Sync feature, F 1 R E ' °' '" . E nothing to set or change at the strobe unit Adapter Strobe Adapter Strobe Bell Plate Description The U -MCS series and U- MCS-6090V, U- MCS- 6090V -W The U -MCS Series uses a terminal block for easy installa- strobes combine state of the art electronics to provide tion and the U- MCS- 6090V, U- MCS -6090V W uses a reliability and low current draw to meet visual life safety pigtail (4 wire) connection. applications.The Adapter feature offers four field select- able candela settings - 15/75, 30/75, 75 or 110. Strobe Synchronization requires the Dual Sync Module or PAD -3. ® � Detail — Adapter Engineering Specifications sc selector switch The visual notification appliances shall be Adapter U -MCS Series or U- MCS-6090V, U- MCS-6090V - -W field selectable The integral universal mounting plate of the U -MCS candela strobe appliance, or approved equal.They shall be provides for easy installation with single gang, double listed to UL1971 (Standard for Safety Signaling Devices for gang or4" square box mounting.The lens construction the Hearing Impaired) for indoor applications, and shall be provides high candela output with low current consump- ADAMFPA/ANSI compliant. tion while meeting UL and ADA standards. The strobe shall produce a flash rate of one (1) flash per The U- MCS- 6090V, U- MCS -6090V W provides the same second over the Operating Voltage Range limits of 16 to strobe choices and is constructed of metal for mounting 32Vdc.The strobe light shall consist of a Xenon flash tube bell or chime devices to the plate. enclosed in a rugged, clear polycarbonate lens. Inputs The U-MCS Series & U- MCS- 6090V, U-MCS-6090V -W shall be compatible with standard reverse polarity circuit supervision by an FACP.The Strobe shall be of low use a Xenon flashtube with solid state circuitry for current design, and shall provide a minimum of four (4 ) maximum reliability and efficiency. Strobes have a • rounded dome shape made of clear polycarbonate. CATALOG NUMBER 2550 field selectable strobe intensity settings, 15/75, 30/75, 75 NOTE: These notification appliances are UL listed and rated and 110 candela. All settings shall be UL 1971 listed for as "special application", which represents appliances which both wall and ceiling mount applications.The selector have been investigated to operate as described in the . switch shall be tamper - resistant. product's installation instructions. It shall not be necessary to remove the strobe from the mounting surface to select the strobe intensity. When Ordering Information • synchronization is required, the strobe shall be compat- ible with the Dual Sync Module, or other source of Stand -Alone Strobes -Wall Mount and Ceiling Mount Siemens BuildingTechnologies, Fire Safety Division Sync Model Part Protocol, and shall not drift out of synchronization. Number Description Number U -MCS Multicandela Selectable Strobe- Red 500 - 699701 The U-MCS Series Stand Alone Strobe shall have an U -MCS -W Multicandela Selectable Strobe - White 500 - 699702 integral universal mounting plate that shall allow mount- ing to single- gang, two -gang, and 4" square backboxes, Retro -Plate Wall Mount as well as FBX -S and FBX -F Surface Boxes. A cover trim Model Part plate shall be included to enhance appearance.There shall Number Description Number • be no mounting holes or screw heads visible. U- MCS -6090V Retro Plate 500 - 699703 Multicandela Selectable Strobe- Red The Series U- MCS-6090V, U- MCS -6090V W Strobe Plate U- MCS- 6090VW Retro Plate 500 - 699704 shall facilitate the addition of a strobe to a bell installation. _ Multicandela Selectable Strobe- Red The Strobe Plate shall mount to a 4° square backbox for flush mounting. - Stand -Alone Strobes -Wall Mount and Ceiling Mount - for Agent Release U -MCS Specifications Model - - Part Number Description Number Environmental U- MCS -AR Multicandela Selectable Strobe - Red 500 - 699746 32 °F to 120 °F (0 °C to 49 °C) at 85% RH For Agent Release Input Voltage - - 16 -32Vdc regulated or FWR Mounting Canadian Ordering Information Integral universal mounting plate mounts to single gang, double gang or 4" square box. Stand -Alone Strobes -Wall Mount and Ceiling Mount Shipping Weight Model Part 9 oz. approx. Number Description Number CU -MCS Multicandela Selectable Strobe- Red 500.699701C U -MCS Dimensions CU -MCS -W Multicandela Selectable Strobe -White _ 500- 699702C 4-5/8* -I 3-1/2' 3 ---I Retro -Plate Wall Mount Model Part FIRE Number Description Number CU- MCS -6090V Retro Plate 500-699703C .......... till Multicandela Selectable Strobe- Red `� 1 1 CU- MCS- 6090VW Retro Plate 500- 699704C 4 5 /W itO = } 1 Multicandela Selectable Strobe- Red tom` 1 i / Strobe intensity Setting Strobe Current Draw FIR E �` Selector 15/75 cd 63 mA . , Switch 30/75 cd 84 mA 75 cd 143 mA 110 cd 178 mA Typical Wiring Do not Loop, 'T' Tap or ♦ 4 branch connect wires. connectsignal T. dreult f From Control Panel Cut wire run to provide POLARITY MARKING or Previous Device or i: To Next Device IS FOR SYSTEM IN For Synchronization from 1::...] s STROBE Ei i or Electrical Su ALARM. Siemens Sync Protocol Source Device Lid TT E .O.L Resistor Use care when poskloning field wires so that minimum itai stress Is on the appflance. Fire Safety Fire Safety 8 Fernwood Road 2 Kenview Boulevard Florham Park. NJ 07932 3/05 Brampton. Ontario Siemens Building Technologies Tel: 593 2600 51N Canada L6T 5E4 9 9 F AX : (973) (973) 5 93 66 SFSIG Tel: (905) 799 -9937 March 2005 Fire Safety Website: www.sbt.siemens.com/fis Printed in U.S.A. FAX: (905) 799-9858 Supersedes 10108, dared 6/04 • SIEMENS Fire Safety U -MHU Series Models U -MHU Electronic Sync /Non -Sync Horn ENGINEER AND ARCHITECT SPECIFICATIONS • The Adapter /U -MCS feature offers four field selectable candela values — 15/75, 30/75, 75 or 110 for wall & ceiling mount 1 ` • Sync strobes and sync temporal horns, with horn 11111 :: 1 silence on 2 wire • Distinctive temporal horn a" t • Internally adjustable volume control 1 • • Low current draw • Single gang and universal mount configurations •r' lIL • UL 1971 & UL 464 listed - CSFM, ULC, FM &NYMEA . at • UL 1971 listed for both wall and ceiling mount • ADA/NFPA/ANSI compliant i a e) `' 3 • Screw terminals accept 12 awg wire • Synchronization requires Dual Sync Control Module or PAD -3 • • Made in U.S.A., ISO 9001 quality crafted Description 15 Detail - Adapter The U- MHU -1 G, U- MHU -1G -W and U -MHU, U -MHU -W ®� selector switch Sync Electronic Homs and U-MHU -MCS, U- MHU -MCS -W Horn Strobes provide synchronous strobes with synchro- An internal volume control provides adjustment of dBA nous temporal tone signals on one pair of wires or output levels. temporal or steady tone in a non -sync mode. The U -MHU -1 G, U -MHU -1 G -W mounts to a single 3 gang box, the U -MHU, U-MHU-W and U-MHU -MCS, U -MHU -MCS -W have a universal mounting plate for °. Volume 1 gang, 2 gang or 4" square box mounting. Detail - Volume adjust Siemens Fire Safety notification appliances are (factory set at max. volume) designed with the installer in mind.They are constructed The U- MHU -MCS, U- MHU -MCS -W strobe construction with the electronics in the housing and not in the box. consists of a Xenon flashtube with solid state circuitry for This design eliminates possible ground faults from maximum reliability and efficiency.The strobe has a crowded electrical boxes.The Adapter /U -MCS feature rounded dome shape made of clear polycarbonate. offers four field selectable candela settings - 15/75, 30/75, 75 or 110. CATALOG NUMBER 2560 Replaces Catalog Sheet Number 2555 The U -MHU -1 G, U- MHU -1 G W, U -MHU, U -MHU -W and Listed operating range is 16 to 32VDC/FWRTemporal U- MHU -MCS, U- MHU -MCS -W are used on circuits with maximum UL measurements are 83.6 db at 24VDC/FWR. steady power or a Dual Sync Control Module or PAD -3. Steady tone maximum UL measurements are 878 db at 24 . Not for use on coded circuits. VDC/FWR taken in free air at 360° around the device and averaged. Typical readings are frontal sound readings taken Environmental with a dB meter with signal mounted on wall. Rated for 32 °F to 120 °F (0 °C to 49°C) with 85% humidity indoor use 32 °F to 120 °F, (0 °C to 49 °C), at RH 85 %. ( -W: White) OperatingVoltage Range Limits NOTE: These notification appliances are UL listed and rated Horn: 16 orVFWR as "special application", which represents appliances which Strobe: 16 - 32Vdc orVFWR have been investigated to operate as described in the product's installation instructions over the voltage range of Typical Hom Ratings at 10 Feet* 16-32VDC or VFWR. Temporal Horn — Maximum: 95 db @ 54 mA Strobe Intensity Setting Strobe Current Draw Minimum: 90 db @ 30 mA 15/75 cd 63 mA 30/75 cd 84 mA * Typical dBA ratings are frontal sound readings 75 cd 143 mA taken with a dB meter with signal mounted on wall. 110 cd 178 mA Dimensions Control Module Specifications: r I 1 J -13r4' r---- 444 - --1 x _ 1 4 , Maximum Current Output: 3 Amps Max. not IT �� to exceed NAC rating m i r DSC Module Operating Voltage: 16 to 32 Vdc orVFW ,- a,rr 44 f4• o Hi DSC Module Operating Current: Non - Silenceable Viii I Circuit side a a 55mA, Silenceable Circuit side .005 Amps. Maximum Current Output: 3 Amps max. not to r_44,4.______.,. i - 2i/2 exceed Circuit rating ' 1, 2 or 4 Square Mounting 1 III9 , � t., - • asr4• FIRE' J. Oi l \ !1, Q i � �, - 0 selector 0 so, . or or 0 414 I For wiring diagram for U -MHU Series Horn/Strobes refer to Installation Instruction Sheet Ordering Information U -MHU Series Hom Wall Mount Low Volume High Volume High Volume Model Number Description Part Number Horn Current Horn Carreat dB Rating 4P10' U- MHU -1G ELC Sync /Non -Sync Horn 24 -VDC 500-699591 30ma 54ina 95 db U- MHU -1G -W EEC Sync /Non -Sync Horn Z4VDC 500- 699592 30ma 54ma 95 db U -MHU ELC Sync/Non Horn 24VDC 500. 699594 30ma 54ma 95 db U -MHU -W ELC Sync/Nan -Sync Hom 24 VDC 500.699593 30ma 54ma 95 db Low Volume High Volume: High Volume Model Number Description Part Number Horn Current Horn Current dB Rating 010' 4J- MHU -MCS 'EEC Sync/Non -Sync Hom w /Strobo:(Red) 500- 599587 30ma 54ma 95 db U- MHU -MCS -W _ EEC Sync/ Non- Sync 500- 699588 30ma 54ma 95 db *Ali current measurements made at 24VDC Canadian Ordering Information CU-MHU Series Hom Wall Mount Low Volume High Volume High Volume Model Number Description Pert Number Hors Current Horn Current dB Rating M10' • CU- MHU -1G EEC Sync/Non-Sync Horn 24 VDC 500.699591C 17ma 25ma 95 db CU- MHU -1G-W ELC Sync/Non -Sync Horn 24VDC 500- 699592C 17ma 25ma 95 db CU -MHU ELC Sync /Non -Sync Horn 24VDC 500-699594C 17ma 25ma 95 db CU -MHU -W ELC Sync/Non -Sync Horn 24 VDC 500- 699593C 17ma 25ma 95 db Low Volume High Volume High Volume Model Number Description Pant Number Horn Current Horn Current dB Rating H10' CU- MHU -MCS ELC Sync/Non- Sync.Horn w /Strobe (Red) 500.699587C 17ma 25ma 95 db CU- MHU -MCS -W ELC Sync /Non•Sync Horn w /Strobe.(White) 5004699588C 17ma 25ma 95 db Wiring Diagrams Typical Wiring for U- MHU -1G and U-MHU for Synchronized Operation with DSC Dual Sync Control Module (Sync and Silenceable Operation) Polarity Shown In Alarm Condition ( Audible Control From control panel silenoeable Notification Appliance Cuci4t (N.A.C.) 0 0 < Audible Power I!!i ; I I' I `, From control panel steady (notrpulsing) non-sffenoeatie Notification Appliance Circuit (NAC.)l mi 1! I IA . . 21. 1 N 1 DSC 1 > — i Individual wires (especially heavy `i 0 ; gauge wire) should be beret at 90' *v 1:0.1 , - ( before attaching to screw. Wiring DC a rtva 1.0. l — .,, _ t should then carefully be pushed o -} '- ?< back into back box to minimize o 0 : � is -. A. * • A. i sasabn _ — yam, 0 stress on the terminal block. nat wee in smreronuedOperatior Supervised and --,0 -° m# powered by NonSilenoeabte •._ • N.A.C. from Fire . To Next Device Alarm Control Unit - — - or E.O.I. Fig. 4 Typical Wiring for U- MHU -1G and U-MHU for Non - Synchronized Operation Polarity Shown InAlarm Condition I From control panel. steady sueneeao(e Gaon Appals* Circuit (N.A.C.) ((( 1 c I Individual wires (especially heavy O ; -- gauge wire) should be beat at Jranper Selection — — j before attaching to screw. Wiring f should then u be pushed OR = Steady On = Steady Horn al Horn t t I back Into back bOxto rllinirrdoe -�- � – p;:� strew on the terminal block Jumper seteaion r" ' Is only Jar use in ' Non- synducnized operation r a —,1- 4 . a To Ned Device — - or E.O.I. Fig. 8 Wiring Diagrams Typical tiring for U- MHU -MCS for Synchronized Operation with DSC Dual Sync Control Module Audible Signal and Strobe on Same Circuit (Audible Signal and Strobe Synchronized), Audible Signal Silenceable Polarity Shawn In Alarm Condtion Note: When staid* and strobe units are powered from the same source. add the currents for both devices. . Audible Control leave Jumpers in Plate From c o n t r o l panel skencaabie Notification Appflanoe C i r c u i t (NA.C.) ' (Strobe sr* Audibro S pred are to Audibto and Strobe Power Overate Same Circuit) /• 0 0 t'� Frtxrtcontrol pan elsteady(nor►pulShp) ricre cadotApplWpaCinx&(N.AL.) ` I;(.1 DSC I ," 1 j 1 ,ttaor IA il I oconvFU� 1,01 • I I, • Individual wires (espoela)y mini — heavy gauge wire) should be 0 0 0 . c.» 1N 0 Li ;_ bent at 90° before coaching • to screw. Wiring should then iF -1.. Y:d carefully be pushed back Into � 'f �l ( '•._• j w. . i1_ r'=' Ne" • I __ back box to minimize stress Supervised Supesed and �{ _ / _ 'l u. _ an the terminal block powered by i ( ! ��ii�. NAC. from Fire w _ �j ��'I il AC. from Fire Alarm Control Unit • To Next Device Jumper - or E.O.L. net used m Synchronized Operation Fig. 6 Typical Wiring for U- MHU -MCS for Non - Synchronized Operation Audible Signal and Strobe on Same Circuit Polarity Shown In Alarm Condition Note: When audible and strobe units are powered from the same source. add the currents for both devices. Leave Jumpers in Plate From control panel, (Strobe are Aurabte Signal are to steady 89enceabie Noti(it: h ApPUance Circuit (NAC.) Operate on • Same Came) a 1t _ NOTE: SQWeraeeobeMar be Comema r IH f f tos tnd ddual wires (especial M+FW:npxotfcatimfocaeroeCia IA. i• r y O..Wec. to - � o o i he heavy gau� should be Jumper Settrt .�. � � 'at-It. N. ! { bald at before attaching On Temporal Nowt ;., ...;,.,!.....,k;.!—. I q to strew. Wifbtg should then on * steady Nom ; I� : i - 1 - ; c efully be pushed back Into �a'sr. ,' — _y_. is ! � a'sr .r eu i • back box to minimize stress Jumper se(ue i n (_= _ lei ��'r f 11 - on the temrbral block is only for - ! far use ! . Non - synchronized . _ operation —• To Next Device or E.O.L Fig. 7 Fire Safety Fire Safety 8 Femwood Road 2 Kenview Boulevard Florham Park, NJ 07932 3/05 Brampton, Ontario Siemens Buildin 'Technologies Tel: (973) 593 -2600 %I Canada L6T5E4 9 9 FAX: (973) 593-6670 SFS"IG Tel: (905) 799 -9937 March 2005 Fire Safety Website: www.sbt.siemens.com/fis Printed in U.S.A. FAX: (905) 799 -9858 supersedes & set detect ero4 " SIEMENS Fire Safety HTRI Series FireFinder XLS and FS -250 Intelligent Initiating Devices Interface Modules ENGINEER AND ARCHITECT SPECIFICATIONS Intelligent Interface Modules for FireFinder XLS and FS -250 Series Fire Alarm Control Panels HTRI -S, HTRI -D, HTRI -R • Interfaces and Supervises Normally Open or Normally Closed Contacts • Integral SPDT Relay (up to 4 amps) on HTRI -R Model • Dual Input on HTRI -D Model using a single address r '+ • Polarity Insensitive with SureWiren" Technology sF - • Multi -color L.E.D. indicates status (green, amber, red) • Easy front access to programming port and a "., wiring terminals • • Mounts 4 inch square 2 1 4 deep box, or double gang box „; b • Dynamic Supervision ESp - • Comes with 5x5 inch faceplate • Two wire operation!- • DPU Device Program/Test Unit programs and Verifies } y , Device's Address and Tests Devices functionality • Electronic Address Programming is Easy and Dependable /-_• • ULC Listed ti y ® CFSM, FM, NYMEAApproved Introduction The HTRI Series Intelligent interface modules are de- monitor and report the status of the contact, while the signed to provide the means of interfacing direct shorting HTRI -R incorporates an addressable Form C relay. The devices to the FireFinder XLS and FS -250 Fire Alarm HTRI -R relay and contact device input are controlled at the Control Panel loop circuit. same address. For the control panel system, the relay The HTRI Series Intelligent interface modules provide the and input contact can be controlled as a separate function. The relay is typically used where control or shunting of market's most advanced method of address programming external equipment is required. and supervision, combined with sophisticated control panel communication. Each HTRI Series interface module The HTRI -D is a dual input module and is designed to incorporates a microcomputer chip. The HTRI Series supervise and monitor two sets of dry contacts. The microcomputer chip technology and its sophisticated Dual Input Module only requires one address but re- bi- directional communication capabilities with the control sponds independently to each input. The HTRI -D is ideal panel, achieve the state of an "Intelligence Device” for monitoring a water flow switch and its respective valve tamper switch. Description The HTRI has a multi -color Light Emitting Diode that The HTRI Series intelligent interface modules are flashes green when operating normally, amber if unit available in three models. The HTRI -S and HTRI -R are is in trouble condition, and red to indicate a change of designed to monitor a normally open or closed dry state. The HTRI -D flashes twice, once for each ad- contact. The interface module reports the contact's dress, the HTRI -R red L.E.D. indicates a change of status to the control panel. The HTRI -S model can only state in the relay. CATALOG NUMBER 6304 The device's microcomputer chip has the capacity of Mounting Data storing, in memory, identification information as well as Addressable Interface Model HTRI -S, HTRI -D, HTRI -R important operating status information. mounts directly into a 4 inch square 2'4 deep box or Siemens BuildingTechnologies, Inc., Fire Safety Division a double gang box (user supplied). A 5 inch square innovative technology allows all HTRI Series intelligent off -white faceplate is included with each HTRI. interface modules to be programmed by using the DPU Device Programming/Test Unit. The DPU is a compact, MOUNTING SLOTS portable, menu driven accessory that makes program- FOR 4 INCH ming and testing an interface device faster, easier and swIrCHBOx more dependable than previous methods. The DPU eliminates the need for mechanical addressing mecha- o • 0 nisms, such as program jumpers, DIP switches or rotary dials, because the DPU electronically sets the HTRI ill HTRI S/ - / - interface's address into the interface's microcomputer tell I MODULE chip nonvolatile memory. Vibration, corrosion and other ® r ; O . conditions that deteriorate mechanical addressing mecha- ' nisms are no longer a cause for concern. 11-•1 H MOUNTING OLEES S FFO HOLES FO The HTRI Series is fitted with screw terminals for ► SWITCHPLATE connection to an addressable circuit. The HTRI Series is fully compatible on the same 0 FireFinder XLS and FS-250 circuits with all intelligent H Series detectors, HMS Series addressable manual stations or any other addressable intelligent modules, MOUNTING SLOTS such as the HZM or HCP. FOR DOUBLEGANG All HTRI Series intelligent interface modules are SWITCHBOX UL listed. Figure A Environmental operating conditions for all HTRI Series Mounting the HTRI S/ - modules are 32 °F ( °C) to 120 °F (49 °C) with a relative humidity of not greater than 93% non -condensating. Ordering Information Electrical Ratings Shipping Wt. Current Draw (Active or Standby): 1 mA Model Description Lb. Kg. Part Number HTRI - Relay Ratings HTRI -S Single Input 7 oz 2 500. 033370 Resistive: 4A, 125 VAC HTRI -R Single Input w /Relay 7 oz 2 500- 033300 4A, 30 VDC • -HTRI -D Dual Input 7 oz 2 500-033360 Inductive: 3.5A, 120 VAC (0.6P.F.) 3.0A, 30 VDC (0.6PE) 2.0A, 120 VAC (0.4PF.) 2.OA, 120 VAC (0.35PE) 2.0A, 30VDC (0.35P.F.) • NOTICE: The use of other than Fire Safety detectors and bases with Fire Safety equipment will be considered a misapplication of Fire Safety equipment and as such void all warranties either expressed or implied with regard to loss, damage, liabilities and/or service problems. Fire Safety Fire Safety 8 Femwood Road 2 Kenview Boulevard Florham Park NJ 07932 12/04 Brampton, Ontario Siemens Building Technologies Tel: (9 51N Canada L6T 5E4 g 9 F AX 3 66 SFSIG Tel: (905) 799 -9937 December 2004 - Fire Safety Website: www.sbt.siemens.com/fis Printed in U.S.A. FAX: (905) 799 -9858 su erseaes sneer dated 1403 .. SIEMENS Fire Safety HTRI-M Dev Interface Module For Use With the FireFinder -XLS Control Panel ENGINEER AND ARCHITECT SPECIFICATIONS Intelligent Interface Modules For FireFinder XLS Control Panels h ,. ,t • Interfaces and Supervises Normally Open (Fire Detection) k #'/ ir or Normally Closed Contacts (Security Detection) i,°;;` • Compact Size Allows Mounting in Single Gang Box Behind Equipment` • Polarity Insensitive with SureWireTMTechnology ;� • Operates with FireFinder XLS DLC Circuit b;' • InnovativeTechnology Supports Comprehensive r ., Er L: System and Interface Communication :rat 1 i atal • Dynamic Supervision M, =mama all • TwoWire Operation '' R ni isfi • DPU Device Progra Unit Electronically ,y, s EM ENS ' , Programs and Verifies Device's Address andTests ' s,.,~„ ponouv . y orT , Device's Functionality 41. • ULC Listed �� �� CSFM, FM and NYMEA Pending Introduction The HTRI -M Intelligent interface module is designed Siemens Building Technologies, Inc.,Fire Safety to provide the means of interfacing direct shorting Division innovative technology allows all HTRI -M devices to the FireFinder XLS system's DLC loop intelligent interface modules to be programmed by circuit. using the DPU Device Program/Test Unit. The DPU is a The HTRI -M Intelligent interface module provides the compact, portable, menu driven accessory that makes e a o ier and more and testing an e interface device faster, market's most advanced method of address program- od ming and supervision, combined with sophisticated easier and more dependable than previous methods. n The DPU eliminates the need for mechanical address- control panel communication. Each with sophisticated interf ing mechanisms, such as program jumpers, DIP module incorporates microcomputer chip technology switches or rotary dials, because it electronically sets and its sophisticated bi-directional communication the HTRI -M interface's address into the interface's • • capabilities with the control panel. microcomputer chip non - volatile memory. Vibration, corrosion and other conditions that deteriorate me- Description chanical addressing mechanisms are no longer a cause The HTRI -M is designed to monitor a normally open or for concern. This HTRI -M is connected to the program/ tester with the programming cable provided with the closed dry contact and reports the contact's status to the control panel. tester. This cable (P /N 110-694927) utilizes two (2) alligator clip connectors, to attach to the HTRI -M. The device's microcomputer chip has the capacity of storing, in memory, identification information as well The HTRI -M Series has five leads, one for grounding, as important operating status information. which are wired to the system with user supplied wire nuts. CATALOG NUMBER 6308 • The HTRI -M is fully compatible on the same XLS • circuit with all intelligent H Series detectors, HMS Series addressable manual stations or any other H Series addressable intelligent modules, such as the HZM or HCP. All HTRI -M intelligent interface modules have been UL and ULC submitted. Environmental operating conditions for all HTRI -M modules are 32 °F ( °C) to 120 °F (49 °C) with a relative humidity of not greater than 93% non - condensating. Ordering Information Model Shipping Weight Part Number Description o:. kg. Number HTRI -M Single Input 3.5 .1 500 - 034000 HTRI -MC ULC Model for Canada 3.5 .1 500- 034000C - Electrical Ratings Current Draw (Active or Standby):. 1.5mA . NOTICE: The use of other than Fire Safety detectors and bases with Fire Safety equipment will be considered a misapplication of Fire Safety equipment and as such void all warranties either expressed or implied with regard to loss, damage. liabilities and/or service problems. Fire Safety Fire Safety 8 Fernwood Road 2 Kenview Boulevard Florham Park, NJ 07932 1/03 Brampton, Ontario • Siemens Buildin Technologies Tel: (973) 593 -2600 5M Canada L6T 5E4 9 9 FAX: (973) 593-6670 SFS -IG Tel: (905) 799 -9937 January .2003 Fire Safety Website: www.sbt.siemens.corn/fis Printed in U.S.A. FAX: (905) 799 -9858 Supersedes sheetdate°1201