Correspondence Si / aO &, ,(4) January 22, 2003 CITY OF T1GAR® Alexander Hurley OREGO AKS Engineering & Forestry 13910 Galbreath Drive, Suite 100 Sherwood, OR 97140 Re: J.T. Roth Office Building — Site Review /aS/r 4-2585 -SW 68 SIT2002 -00036 Dear Mr. Hurley, The City of Tigard Building Division has performed a plan review for the site at the above referenced project. This review was performed under the provisions of the State of Oregon Structural Specialty Code (OSSC), 1998 edition and the Uniform Fire Code as amended by Tualatin Valley Fire & Rescue (UFC). The following information is required prior to approval and issuance of the site permit. 1. The engineer seal is over stamped with "Preliminary, Not for Construction." Please submit revised plans without this statement. 2. Note 5 under "Site Specific" indicates the site will be engineered grading in accordance with OSSC Appendix 33. Please identify whom will be responsible for special inspection and testing of the engineered fill. 3. Provide structural calculations and construction drawings for the proposed retaining wall along the south and west property lines. These walls appear to be supporting a surcharge of the parking lot. If you have any questions or concerns, please contact me at (503) 718 -2448. Sincerely, G ampella - Building Official c. J.T. Roth Construction Hap Watkins, Supervising Inspector File 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772 CITY OF TIGARD OREGON February 25, 2003 Alexander Hurley AKS Engineering & Forestry • 13910 Galbreath Drive, Suite 100 Sherwood, OR 97140 Re: J.T. Roth Office Building — Site Review "59€�W 68 �aS 8 SIT2002 -00036 Dear Mr. Hurley, The City of Tigard Building Division has performed a plan review for the site at the above referenced project. This review was performed under the provisions of the State of Oregon Structural Specialty Code (OSSC), 1998 edition and the Uniform Fire Code as amended by Tualatin Valley Fire & Rescue (UFC). The plans are approved subject to the following conditions. 1. The foundation system is proposed using standard footings and foundation walls with post & beam construction. Geo- Pacific will be performing the grading, fill and compaction for the parking lot as specified on the plans. They shall visually inspect the excavation for the foundation system to ensure the soil bearing capacity is adequate for the footing design. Any discrepancies or special conditions shall be brought to the immediate attention of the contractor for correction. If corrective measures or fill is to be placed at the building pad, all inspection records shall be forwarded to the attention of Hap Watkins, Supervising Inspector at 13125 SW Hall Blvd., Tigard, OR 97223. 2. A copy of the approved plans shall be on the job site at all times and available to the City of Tigard inspectors for inspection purposes. OSSC Section 106.4.2. 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772 3. The accessible parking space shall be a minimum of 9 feet wide with an access aisle on the passenger side not Tess than 8 feet in width. If the accessible parking sign is pole mounted, it shall be a minimum of 7 feet above grade. Wall mounted signs shall be reasonably mounted so they are visible to occupants in vehicles. An additional sign shall be mounted below the regular sign indicating this is a "Van Accessible" space. OSSC Section 1104.1 and ORS 447.233. 4. A final inspection and final approval shall be obtained for all work under this permit prior to final approval and occupancy of the proposed office building on this site. If you have any questions or concerns, please contact me at (503) 718 -2448. Sincerely, Gary Lampella Building Official c. J.T. Roth Construction Hap Watkins, Supervising Inspector File