Plans • PIfO _i - 000(03 • City of Tigard, Oregon • 13125 SW Hall Blvd. • Tigard, OR 97223 February 5, 2008 1 RE: MECHANICAL Proiect Information T I GARD Building Permit: MEC2008 -00063 Construction Type: 5 -B Tenant Name: HP Northwest Occupancy Type: B Address: 12511 SW Pacific Hwy. Occupant Load: NA Area: NA Stories: NA The plan review was performed under the State of Oregon Mechanical Specialty Code (OMSC) 2007 edition; and the State of Oregon Fire Code (OFC) 2007 edition. The submitted plans are approved subject to the following. 1. Each appliance shall be provided with a shutoff valve separate from the appliance. The shutoff valve shall be located in the same room and within six feet of the appliance served. Access shall be provided to the shutoff valve. C409.5 OMSC 2. Equipment and appliances regulated by this code requiring electrical connections shall have a positive means of disconnect in accordance with the Electrical Code. 301.7 OMSC 3. Appliances shall be accessible for inspection, service, repair or replacement without removal of permanent construction. 306.1 OMSC 4. Manufacturer's installation instructions shall be available on the jobsite at the time of inspection. 304.1 OMSC 5. Condensate from cooling coils or evaporators shall be collected and discharged to an approved plumbing fixture or disposal area. 307.1 OMSC 6. Compressor shall be mechanically connected to the roof. Approved Plans: 1 set of approved plans, bearing the City of Tigard approval stamp, shall be maintained on the jobsite. The plans shall be available to the Building Division inspectors throughout all phases of construction. 106.4.2 OSSC Premises Identification: Approved numbers or addresses shall be provided for all new buildings in such a position as to be plainly visible and legible from the street or road fronting the property. When submitting revised drawings or additional information, please attach a copy of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. Respectfully, Dan Nelson, Senior Plans Examiner (503)718 -2436 dann c@tigard- or.com Phone: 503.639.4171 • Fax: 503.684.7297 • www.tigard- or.gov • TTY Relay: 503.684.2772 ,- -� • * ," Submittal Data System 24CL FUJITSU 0 ASU24CL & AOU24CL Job Name: Location: Purchaser: Engineer: - Submitted To: For: ❑ Reference ❑ Approval ❑ Construction Submitted By: . OUTLINE AND DIMENSIONS IINENI Capacities: _ I a Cooling 24200 BTU/h Min/Max Cooling 5,200- 26,000BTU/h Outdoor Design Temperature F° DB /WB 95/75 39.114• 9• SEER . _ 18.0 EER 10.5 h� 31 -1/8' 2 411 , 1 2 - Low Ambient Temp F. 14 IONS N111•11111111•1•1•111111■■•■1•1111■1 Mom Voltage/Frequency /Phase 208 - 230/60/1 - -7'.--- -_i I Indoor Unit: �` Noise Level db (A) - H /M/VQ 47/41/36/32 e = — ___ - - *roof I Weight 31 lbs. _ — Outdoor Unit: — _ —_____ Noise Level db (A) _ 52 = AIM Recommended Fuse Size _ 29A - Min. Ampacity 21A 8118 Running Current (Rated/Max) 10.1/12.0 Standard Features: Weight 97 lbs. Refrigerant Piping: • Six year compressor warranty • Sleep timer; 24 hour timer Max Ht. Difference 66 ft. • Two year parts warranty • Built in Low Ambient Max Total or Combined Length - 98 R. • Refrigerant R410A • Auto Restart/ Reset Discharge Vapor Line (O.D.) 1 /4.in. Suction (O.D.) 5/8 in. • Auto Louver: 4 Way • Dry Mode Note: Figures are based on 230 Volts • Auto Mode: Quiet Mode • Power Diffuser • Ion Deodorizing Filter • Apple Catechin Filter CITY OF TIGARD • Cold Prevention • Optional Wired Remote Appeved ••••••• Control Conditionally Approved • Digital Wireless Remote S00 latilar t FollOil 3 Control Atd N _ 7 t :N sr- .. , 2 OFFICE COPY