Correspondence (471) &f May 11, 2005 • CITY OF.TIGARD .P 41+ OREGON Triplett Wellman, Inc. CO Nick Wellman Ay 1717 Mount Jefferson Ave Woodburn, OR 97071 RE: PRELIMINARY PLAN REVIEW Project Information Site Permit: BUP2005-00148 Construction Type: V - B Tenant Name: Cascade Veterinary Occupancy Type: B Address: 11140 SW 68 Parkway Occupant Load: 50 + Area: l 7,960 sf, 2 1,650 sf Stories: 2 The plan review was performed under the State of Oregon Structural Specialty Code (OSSC) 2004 edition; and the Tualatin Valley Fire & Rescue Fire & Life Safety Requirements for Fire Department Access and Water Supplies (Based on the 2003 International Fire Code as amended by TVF &R). The submitted plans are approved subject to the following. GENERAL 1. Erosion control measures shall be in place prior to excavation or grading. 2. The Retaining Wall is to be installed per engineer design. 3. Special Inspection: Special inspection is required for structural masonry. The special inspection agency shall furnish inspection reports to the Engineer of Record Chris C Van Vleet, the General Contractor, Triplett Wellman, Inc. and the City of Tigard, Building Division, attention Hap Watkins. All discrepancies shall be brought to the immediate attention of the general contractor for correction. The special inspector shall submit a final signed report stating whether the work requiring special inspection was, to the best of the inspector's knowledge, in conformance with the approved plans and specifications and the applicable workmanship provisions of the code. 1704 OSSC 4. The backfill shall be placed in lifts and compacted, in a manner that does not damage the foundation. 1803.2 OSSC The excavation outside the foundation shall be backfilled with soil that is free of organic material, construction debris, cobbles and boulders or a controlled low- strength material (CLSM). 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772 FIRE DEPARTMENT ACCESS 5. The driveway is considered a fire department access roadway. The driveway shall be capable of supporting a 12,500 pound wheel point load and a gross vehicle weight of 50,000 pounds. ACCESSIBILITY 6. Accessible walkways and routes shall not exceed a running slope of 1 unit vertical in 20 units horizontal (5% slope). Cross slopes shall not exceed 1 unit vertical in 50 units horizontal (2% slope). 7. Accessible parking spaces and access aisles shall be located on a surface with a slope not to exceed 1 unit vertical in 50 units horizontal in all directions. 1104.4.3 OSSC Approved Plans: 1 set of approved plans, bearing the City of Tigard approval stamp, shall be maintained on the jobsite. The plans shall be available to the Building Division inspectors throughout all phases of construction. 106.4.2 OSSC American with Disabilities Act (ADA): It shall be the responsibility of the Architect, Engineer, Designer, Contractor, Owner and Lessee to research the applicability of the ADA requirements for the structure. The City of Tigard reviews the plans and inspects the structure only for compliance with Chapter 11 of the OSSC which may not include all of the requirements of the ADA Premises Identification: Approved numbers or addresses shall be provided for all new buildings in such a position as to be plainly visible and legible from the street or road fronting the property. When submitting revised drawings or additional information, please attach a copy of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. Resp a Z17 Senior Plans Examiner ?_, r 60p :96z4 RECEIVED MAY 0 9 200 CITY OF TIGARD BUILDING DIVISION 'VAR Fire Marshal's Division Offices Tualatin Valley North - 14480 SW Jenkins Rd., Beaverton, OR 97005, (503) 356 -4700 Fire & Rescue South - 7401 SW Wash Ct., Tualatin, OR 97062, (503) 612 -7010 Fire Flow and Hydrant Worksheet This worksheet is required to be submitted to and approved by the Authority Having Jurisdiction (AHJ) before any permits for new building construction, building expansion or fire hydrants will be issued by any building department within the TVF &R District. See the instructions for assistance completing this form or call one of the above numbers. Preparer Information Preparer Name: (Chris C. VanVleet P.E. - Lewis & VanVleet inc. Phone: [503.885.8605 I Fax:1503.885.1206 I 0 1 Architect / Engineer of Record: (Studio 3 Architecture .08) Phone:1503.390.6500 1 Fax: (503.390.6501 1 General Building Information Project Name: !Cascade Veterinary Referral Center Project Address: 111140 S.W. 68th Parkway 1 City:1Tigard 1 County:1Washington 1 Zip:197223 1 Construction Type(s): Type V -B Total Bldg Area: ( 9,6121sgft Total Fire Area: 1 9,6121sgft Bldg Fire Flow: 1 26471Gallons Per Minute Describe Fire Area: (If more than one fire area, include an 81/2 x 11 or 11 x 17 drawing Indicating the various fire areas) Ground Floor Area = 7962 square feet Second Floor Area = 1650 square feet Type of Occupancy or Use of Building: 1B • • IA. Single Occupancy Hazard (If using Item A, DO NOT use Item B) I Al Building Fire Flow I 2647jGPM A2 Occupancy Factor I 11 A3 Required Fire Flow 1 2647IGPM (Use Either Item A Above or Item B Below, But Not Both I B. Multiple Occupancy Hazard (If using Item B, DO NOT use Item A) I B1 Determine percent of each occupancy hazard in the fire area. Occupancy Hazard Class Fire.Area 1 Total. Fire Area 'Percent of Fire Area . Light Hazard 0 SF 1 1 SF x.100 0 % Ordinary Hazard Grp 1 0 SF 1 1 SF x 100 0% Ordinary Hazard Grp 2 0 SF .i 1 SF x 100 0 % Extra Hazard Grp 1 0 SF 1 1 SF x 1110 . 0 Extra Hazard Grp 2 0 SF 1 1 SF x 100 0% Total Must equal 100% ( 0 % I B2 Calculate Fire Flow Occupancy Hazard Class Factor Fire Area Fire Flow Bldg Fire Flow Light Hazard 1.0 x 0 % x 2647 GPM = 0 GPM Ordinary Hazard Grp 1 1.2 x 0 % x 2647 GPM = 0 GPM Ordinary Hazard Grp 2 1.3 .x 0 % x ' 2647 GPM 0 GPM Extra Hazard Grp 1 1.4 x 0 % x 2647 GPM = 0 GPM ,Extra Hazard Grp 2 1.5 x _ 0 % x - 2647 GPM 0 GPM B3 Required Fire Flow 1 0 GPM I C. Minimum Number of Fire Hydrants Required I Required Fire Flow 2647 = ( 3 INo. of Hydrants Required ID. Reduction of Fire Flow - Reductions are based on the following: I D1 - Reduced by 25% for a NFPA 72 Fire Alarm System (multiply by .75) D2 - Reduced by 75% for NFPA 13 Automatic Sprinklers (multiply by .25) IE. Required Fire Flow I El. Fire Flow 2647 GPM X 1 1 1 = 1 2647 GPM (Max. 3000 - Min. 1500 gpm) 1 IF. Available Fire Flow to the Building I Test Results: I 3,690 GPM Manually enter available fire flow here. Please attach documentation of the flow test that was made. It shall include date, time, location of static/residual and flow hydrants, and the tester's name, phone number and address. - 05/04/05 WED 14:21 FAX 503 591 0986 TVWD ENGINEERING ft001 ' I / 16) TUALATIN VALLEY WATER DISTRICT /� FIRE HYDRANT FLOW TEST REPORT Location: A 7 i4 s �LJ 65 -7-4- ‘ A Date: _s i ' S7S 9 Test Made By: (Company & Individual) UU 3 Witness: ,/7/ j Z T Time: 5' Yr Purpose of Test: 0 �'9 -cc , / y #1 #2 #3 #4 Total Flow Hydrant Ports GPM C = Hydrant Coefficient D = Inside Dia. Of Outlet, in. P = Pitot Reading 1 7_5 — .7.- ? i Q =GPM r : ,.r , Flow equation: Q = 29.83 C D (P) ; Use C = 0.9 for hydrant pitot flow gauge See Hydrant Monster data for flow equation. Flow tubes Used? Yes No Hose Monster Used? Yes No }X No. of ports flowed at a time: Static Pressure Y5 psi Residual Pressure "?U psi i Flow at 20 psi Residual Pressure (Calculated) 34`7c 1‘f/ ' " 117 ">' • pm 4 0 x/1/99 Remarks ∎ Location Map: Show on map which hydrants were flowed and which were used to monitor residual pressure. Label ports #1, #2, etc. l /e w ' .ty I /Pit s ,.4../4...1. Notes: i . ; 4' /96 Esc - s 6 few 51.4./ '��..,.L The mapping, flow, or pressure information contained herein reflects conditions on the date and time of the test. Tualatin Valley Water District makes no representations as to the system's ability to meet specific fire flow requirements. Future system capability may differ from the flows reported herein because of subsequent modifications to the District's system andlor because flow and pressure may vary by time of day and season. 4FHtestform.doC