Correspondence (475) P, 601 6x -(9o3 ic. ._ i�,,,,, Diu �, CITY OF TIGARD March 3, 2003 OREGO Ronald James Ped, Architect I A 4742 Liberty Rd. S #194 r I ( Salem, OR 97302 Re: Bank of Tigard Proiect Information Address: 10998 SW 68 Parkway Type of Construction: VN Permit #: BUP2002 -00396 Sprinklered: No Occupancy: B Fire Walls: North & east Walls Occupant Load: 28 Floor Area: 3,713 Sq. Ft. Stories: 2 The City of Tigard Building Division has reviewed the submitted building plans for the above referenced address in accordance with the Oregon Structural Specialty Code (OSSC), 1998 edition and Uniform Fire Code (UFC) as amended by Tualatin Valley Fire & Rescue,. The plans are approved subject to the following conditions. 1. The site preparation and footings shall be in accordance with the Geotechnical Investigation prepared by Redmond & Associates. Any required engineered fill shall have special inspection in accordance with OSSC Chapter 17. Reports shall be sent to Hap Watkins, Inspection Supervisor at 13125 SW Hall Blvd., Tigard, OR 97223. Any discrepancies shall be brought to the immediate attention of the architecture or engineer of record. 2. Due to the location of the building in relation to property lines, the north wall and a portion of the east wall are required to be of not less than one -hour fire - restive construction. Openings such as doors or windows within 10 feet of the property line are required to be protected by fire assemblies having a fire - protection rating of not less the 45- minutes. Openings within 5 feet of the property line are prohibited. OSSC Table 5 -A 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772 1 i 3. In lieu of the parapets at the above rated walls, Exception 5 of OSSC Section 709.4.1 is being utilized. As well as the required one -hour construction, a Class B roof is required and there shall be no openings within 10feet of the exterior one -hour walls,. OSSC Table 5 -A and 709.4.1. 4. Fire - resistive assemblies shall be maintained and all penetrations through such assemblies shall be protected with penetration firestops in accordance with OSSC 709.6 through 709.7 and 714. 5. Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. OSSC 1003.3.1.8. 6. Stairways and handrails shall comply with the provisions of OSSC 1003.3.3.1 through 1003.3.3.7. 7. At least one accessible service counter shall be provided that is at least 36 inches long and not more than 36 inches above the finished floor. OSSC 1108.4.7.2 and 1109.23.2. 8. Accessible parking shall be installed and signed in accordance with OSSC 1104.1 and ORS 447.233. 9. Handles, pulls, latches, locks and other operating devices on doors, cabinets, plumbing fixtures and storage facilities shall have level or other shape permitting operation by wrist or arm pressure and not require tight grasping, pinching or twisting to operate. OSSC 1109.3.1. 10. Mounting heights for environmental and other controls, dispensers, electrical and communication equipment system receptacles on walls and other operable equipment shall be within at least one of the reach ranges specified in Section 1109.2, and not less than 36 inches above the floor. OSSC 1109.3.2. 11. Floor coverings and surfaces shall comply with OSSC 1109.6 for accessibility. 12. Stairways shall comply with OSSC 1109.8 for accessibility. 13. Doors shall comply with the requirements of 1109.9 for width, maneuvering clearances, thresholds, closers, hardware and opening force. The opening force for exterior doors shall not exceed 8 '/z pounds and interior door 5 pounds. • 14. Minimum 2A,10BC fire extinguishers shall be provided throughout the building so the travel distance between extinguishers does not exceed 75 feet. UFC Standard 10 -1. 15.A copy of the approved plans shall be on the job site at all times and available to the City of Tigard inspectors for inspection purposes. OSSC Section 106.4.2. 16.A final inspection and Certificate of Occupancy is required prior to occupying for the intended use of this building or parts thereof. OSSC Section 109.1. If you have questions regarding this review, please contact me at (503) 718 - 2448. Sincerely, 61 ` A le Gary Lampella Building Official c. Hap Watkins, Supervising Inspector File