Loading...
Plans 5'herman Engineering, Inc. (503) 230 -8876 Ph 1410 NW Kearney #5 17. Portland, OR 97209 (503) 226 -4745 Pax MEMORANDUM OFFICE COP ECER /ED TO: Mr. David Bissett & Associates. Inc. JUN 0 7 2004 322 NW Davis Ave., Ste. 301 CITY OF TIGARD Portland, OR 97209 BUILDING DIVISION (503) 224 -231 fax DATE: .Tune 3, 2004 FROM: Don Sherman, PE Principal RE: Spectrum Office Bldg 5 w 6 Tigard, Oregon B up .z oD Lit ^ D O'B ? NOTE: �` / This memo is to inform you of my recommendation for the installation of the holdown anchors. It is my understanding the HD8A holdowns have not been installed in the proper locations. I have reviewed the design uplift and determined the locations that have been offset below the windows are too far from the shear panel locations to allow for solid blocking and through bolts. I recommend installing new anchor bolts with Simpson SET epoxy per our detail R4. If you have any questions please give me a call. CC: Andy, Beacon Homes (503) 570 -8869 fax File- BIS060304.doc .101 PROF 0 4.//&.t: N :,k 9pspOrt `�1.Y 14 AO: 1SHERMAN EN &INEERI ING. 1410 NH , 115r1, PORTLAND, OR + ,. , ... ( ) 22 -4146 FAX (50 29O -aS16 PHONE City of Tigard Approved Plans By ($13 Date 6 - 9 ' °`, HOLDOWN PER PLAN TO bX STUD W/ BOLTS PER MFGR NOTE; E = 4 GTSK AS REQ'D PROVIDE EDGE NAIL'G PER PLAN _ 4 STAGG ® 4X6 T.O. FOUND WALL 4 A301 THRD ROD IN II IMPS ON SET EPDXY 11 � 1 11 r I 4 J --- 1.1 —�— ' 4 II I I .S `II , c 11 i 4 n 11 a w A �, 11 p 11 F SHEAR V4ALL NOLDOI1N HLDHDBA -Exist SCALE: 1" = I -O" 6 -3 -04 5 PPC)Tre-u 44 e Sherman Engmeertnq, Inc. (503) 230 -8876 Ph 420 NW 11" Ave. #5 1 1 , Portland. OR 97209 (503) 274-26 I 2 Fax MEMORANDUM 4/I A - ) RECEIVED TO: Mr. David Bissett & Associates, Tt,c. MAY 1 8 �0D4 322 NW Davis Ave., Ste. 301 Portland, OR 97209 CITY OF TIGARD (503) 224 - 2311 fax BUILDING DIVISION DATE: May 16, 2004 FROM: Don Sherman, PE Principal RE: 67 Ave. Spectrum Bldg / o � 03 Beaverton, Oregon NOTE: This memo is to inform you of my recommendation for the support of the truss joist roof trusses. It is my understanding the trusses have been madc 5" too short due to the revised wall construction. I have spoken with Kathy Olson at Trus Joist and she informed me the required bearing is only 2 -1/4 ". I recommend adding a 3x10 ledger at the double top plate with (3) three ''Y:" lag bolts at 16" centers a minimum of 4" into the studs. The holes should be predrilled • to avoid splitting the studs. If you have any questions please give me a call. G‘11 Cov PtOate 0 PAW 5 r 8y 2 p 0 1rar �,e., ab�P 4.1p 3NEONA CC: Kathy Olson, Trus Joist (503) 526 -1937 fax 1�'P1RSS.d' rile- B1S051 OFFICE COPY °- �4�o RN Y, Asa,, P�zTi gtaoa L1V " IP 11`l E 1 `l l �I I �IJ. 1 VLi . (S05) 226 - 4145 FAX (509) 230-8016 PHONE 1 PROS \4 4,.EN a/a e ,. 111116 ; tr ZIOP ORBICIN dbitt SHE� : 6# ._1 ICJ 2X4 ST11D5 LAP TO ROOF TRurzcs W/ (2) I6D ROOF SHTG PER PLAN TOP a DOT 16-1, 9u10 LEDGER rvi (3) 1/2' DMA. , LAG BOLTS 0 16" O.G. I \ 00F TRUSSES PER PLAN WALL SI4TG PER PLA RO I PARAPET V1IALL /ROOF TRU55E5 RFT62 SGALE :I" _ l'-O" 5-16 -04-