Loading...
Correspondence (577) e • . ,,s DAVID BISSETT & ASSOCIATES ARCHITECTURE • PLANNING • INTERIORS MEMORANDUM o ��,a00 1 May 7, 2004 v To: Brian Blalock /City of Tigard From: David Bissett/DBA RE: SPECTRUM OFFICE BUILDING 12703 SW 67 AVENUE Brian: Attached is the substitute UL Design No. 305 for the 1 hour bearing wall detail for this project. Andy Cunningham at Beacon Home NW indicated this is acceptable to you. Please indicate city approval and mail me a copy. Th ��u! ALA / j r 4 /,, l D 4VA. Bi : "ett (AIA, .BARB r Cc: Andy Cunningham File ' .I1 1 , / AID ETT • es R . ON I r \ cad c c 4;OFO 322 NW 5th Avenue • Portland, Oregon 97209 • (503) 226 -6785 • Fax (503) 224 -2311 08/11/04 WED 09:33 FAX 503 684 0954 CARLSON TESTING i1002 Main Office Salem Office Bend Office P.O. Box 23814 4060 Hudson Ave_, NE P.O. Box 7918 Testing Tigard, Oregon 97281 Salem, OR 97301 Bend, OR 97708 Carlson Inc. Phone (503) 684-3460 Phone (503) 589 -1252 Phone (541) 330 -9155 FAX (503) 684 0954 FAX (503) 589.1309 FAX (541) 330 -9163 Special Inspection FINAL SUMMARY LETTER August 11, 2004 T0405670_CTI City of Tigard 13125 SW Hall Blvd., FILE C Tigard, OR 97223 -8199 Attn: Building Department Re: Spectrum Office — Tenant Improvement 12703 SW 67 Avenue, Tigard, OR Permit No.: BUP2004 -00089 Dear Sir or Madam: This is to certify that in accordance with Section 1701 of the Uniform Building Code, Title 24, we have performed special inspection of the following item(s) per our inspection reports only: Installation of Adhesive Anchors All inspections and tests were performed and reported according to the requirements of Project Documents and, to the best of our knowledge, the work was in conformance with the approved plans and specifications, approved change orders and applicable workmanship provisions of the State Building Code and Standards, as well as the structural engineer's design changes, approvals and verbal instructions. Our reports pertain to the material tested /inspected only. Information contained herein is not to be reproduced, except in full, without prior authorization from this office. if there are any further questions regarding this matter, please do not hesitate to contact this office. Respectfully submitted, CARLSON TESTING, INC. es) - /?7, '/?4 Andrew M. Ewing President mbw CC: Beacon Homes NW Inc — Andrew Gillingham Sherman Engineering Inc April 8, 2004 CITY OF TIGARD David A. Bissett OREGON DAVID BISSETT & ASSOCIATES 322 NW 5 Avenue, #301 Portland, OR 97209 RE: SPECTRUM OFFICE BUILDING /SITE PERMIT Site Permit: BUP2004 -00089 Construction Type: VN Tenant Name: Speculative Occupancy Type: B Address: 12703 SW 67 Avenue Occupant Load: 23 Area: 2,310 Sq Ft Stories: 1 The plan review was performed under the State of Oregon Structural Specialty Code (OSSC) 1998 edition; and the Tualatin Valley Fire & Rescue Ordinance 99 -01 (TVFR99 -01) 1999 edition. The submitted plans are approved subject to the following conditions. 1. NORTH, SOUTH & WEST walls shall be 1 hour rated due to location on property. 2. Openings are not permitted in the North & South walls. The structure will have openings framed in but will be in- filled until the property line has been adjusted to permit openings. 3. Parapet walls are required on the North & South sides of the structure. 4. The "Covered Entry" will require 2 layers of gypsum applied to the underside of the roof joist to comply with section 709.4.1 Exception 5.2 OSSC See attached item 21- 1.1, from Table 7 -C. No vents within 5 feet of property line. 5. The means of egress shall be provided with illumination of not less than 1 foot candle at the floor level anytime the building is occupied. The means of egress illumination shall be provided with a second source of power in case of primary power loss. 1003.2.9.2 OSSC 6. Provide one 2 -A rated fire extinguisher in the new area. The extinguisher shall be located so that no usable space has a distance greater than 75 feet to the extinguisher. Standard 10 -1, Chapter 3 TVFR99 -01. Deferred submittals such as Mechanical, Truss Joist Shop Drawings, etc, will be charged a } deferred submittal fee based on the valuation of the portion of the work being deferred. The minimum fee shall be $200.00. 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772 American with Disabilities Act (ADA): It shall be the responsibility of the Architect, Engineer, Designer, Contractor, Owner and Lessee to research the applicability of the ADA requirements for the structure. The City of Tigard reviews the plans and inspects the structure only for compliance with Chapter 11 of the OSSC which may not include all of the requirements of the ADA. Approved Plans: 1 set of approved plans, bearing the City of Tigard approval stamp, shall be maintained on the jobsite. The plans shall be available to the Building Division inspectors throughout all phases of construction. 106.4.2 OSSC Certificate of Occupancy: No building or structure shall be used or occupied until the Building Official has issued a certificate of occupancy 109.1 OSSC Premises Identification: Approved numbers or addresses shall be provided for all new buildings in such a position as to be plainly visible and legible from the street or road fronting the property. When submitting revised drawings or additional information, please attach a copy of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. Respectfully an Blame Senio ans Examiner