Loading...
Correspondence Carlson Testing, Man Office Salem Off b e u r 200s-a,e) 77 Bend Office Inc. A O 8430 SW Ifun.iker 4060 Hudson Sr, NF, 63025 OB Ri7 Rd #11 Tigard, OR 97113 Salem, OR 9730/ Beth/. OR 97701 Phone: (503) 684 -3460 Phone: (503) 589 -1151 Phone: (541) 330 -9155 Construction Materials Testing & Inspection F. 1503 /684 -0954 Fax (503)589 -1309 Fax (541)330-9163 Special Inspection FINAL SUMMARY LETTER October 14, 2008 T0807197 City of Tigard 13125 SW Hall Blvd Tigard, OR 97223 -8199 Attn: Building Department Re: Winco Foods Store #23 — Addition 7501 Dartmouth Road — Tigard, OR Permit No.: BUP2008 -00079 Dear Sir or Madam: This is to certify that in accordance with Section 1704.1.2 of the International Building Code, we have performed special inspection of the following item(s) per our inspection reports only: Reinforced Concrete Installation of Cast in Place Anchors and Adhesive Anchors Structural Masonry Structural Welding- Shop & Field All inspections and tests were performed and reported according to the requirements of Project Documents and, to the best of our knowledge, the work was in conformance with the approved plans and specifications, approved change orders and applicable workmanship provisions of the State Building Code and Standards, as well as the structural engineer's design changes, approvals and verbal instructions. Our reports pertain to the material tested /inspected only. Information contained herein is not to be reproduced, except in full, without prior authorization from this office. If there are any further questions regarding this matter, please do not hesitate to contact this office. Respectfully submitted, CARLSON TESTING, INC. teven W. L ach Project Manager SW L/rc cc: Zipper Zeman Associates Inc — Andrea F Kuehnel PE City of Tigard Building Division — Hap Watkins Stapley Engineering — Greg Leishman Bruce W Petersen Ncarb ESI Construction - Richard Brien 4 October 20, 2008 r erracon Consulting Engineers & Scientists 12400 SE Freeman Way, Suite 102 Portland, Oregon 97222 503 659.3281 WinCo Foods LLC Ph Fax 503.659.1287 650 North Armstrong Place www.terracon com Boise, Idaho 83704 Attn: Mr. David Van Etten, Vice President Re: WinCo Foods Store #23 — Building Addition 7501 Dartmouth Avenue Tigard, Oregon Terracon Project No. 82081002 Permit # BUP- 2008 -00079 Terracon Consultants, Inc. provided geotechnical observation during construction of the building addition for the WinCo Foods Store addition project in Tigard, Oregon. A representative of Terracon was on -site periodically to observe the construction. Our site observations have been documented in daily field reports, and a brief summary follows. The geotechnical report was prepared by Terracon Consultants, Inc. and dated May 11, 2005. The project plans prepared by Bruce W. Peterson NCARB Architect (Sheet S1 dated March 7, 2008) reference the geotechnical report recommended soil improvements below foundations. Foundation Bearing Soil Observation and Testing A Terracon representative was onsite to observe Geopier rammed aggregate piers constructed at the site under Permit # BUP- 2008 - 00169. As documented in our field observation reports and in our Summary Letter dated June 17, 2008, the geopiers appeared to be constructed in general accordance with the project plans and the recommendations in the geotechnical report. Foundation subgrades were observed and tested by a Terracon representative and consisted of a combination of native silty clay soils or sandy gravel with clay fill. In our opinion, the bearing soil we observed was prepared in general accordance with the project specifications and the recommendations in the geotechnical report. In addition to the foundation bearing subgrades, we observed and tested the grade beam and floor slab subgrade areas. Limited areas that were observed to be loose or disturbed were re- compacted by the contractor. Based on our observations, it is our opinion that the floor slab and grade beam subgrade areas were prepared in general accordance with the project specifications and the geotechnical report. Delivering Success for Clients and Employees Since 1965 More Than 95 Offices Nationwide WinCo Foods Store #23 1T!rr7COn Tigard, Oregon Project No. 82081002 /Permit #BUP- 2008 -00079 October 20, 2008 Structural Fill Observation and Testing A Terracon representative was periodically on -site for observation and testing of backfill of foundations, grade beams, foundation walls, and utility trenches. Structural fill materials placed for floor slab base course materials were also observed and tested. Backfill materials within the building pad generally consisted of the excavated silt or silty gravel fill. Fill was compacted with one of the following: a smooth -drum vibratory roller; vibratory plate compactor; or a backhoe- mounted compactor in limited access areas. The base course materials consisted of imported crushed rock fill that was compacted using the similar methods as for backfill materials. Based on our testing and observations, it is our opinion that the structural fill observed was placed and compacted in general accordance with project specifications. We trust this letter meets your current needs. Please do not hesitate to contact us should you have any questions. �� co pR pFec,s Sincerely, � 5 �N('IIV� iO�` TERRACON CONSULT -04, IN9.. . -7 0 - p r . LOREGON ��p°�� / ' 14 Andrea F. Kuehnel, P.E. Q ` DER A A �. Kris opher T. Hauck, P.E. Senior Engineer F. F. 10 Office Manager Distribution: Addressee P.ii=WAi (WE: b WinCo Foods --Jack Clo T Fd (1) Stapley Engineers - Greg Leishman, PE Bruce W. Peterson, NCARB - Lee Lizama, AIA City of Tigard - Building Permits - Walter Bennett IV (1) ESI Construction - Richard Brien (1) ESI Construction - Mike Tsu (e -mail only) 2 OCT -14 -2008 TUE 04:45 PM CARLSON TESTING INC. FAX NO. 5036840954 P. 02/02 Mtn dI3nS /06A g 10 SI. lie 63 OyRArvFJd1! PAanc Send Carlson Testing, Inc. ,6 >v<� F " � ,� ° „m ; 136 Construction Materials Testing & rns action v , Special Inspection FINAL SUMMARY LETTER October 14, 2008 T0807197 City of Tigard 13125 SW Hall Blvd Tigard, OR 97223 -8199 Attn: Building Department Re: Winco Foods Store #23 — Addition 7501 Dartmouth Road — Tigard, OR Permit No.: BUP2008 -00079 Dear Sir or Madam: This is to certify that in accordance with Section 1704.1.2 of the International Building Code, we have performed special inspection of the following item(s) per our inspection reports only: Reinforced Concrete Installation of Cast in Place Anchors and Adhesive Anchors Structural Masonry Structural Welding- Shop & Field All inspections and tests were performed and reported according to the requirements of Protect Documents and, to the best of our knowledge, the work was in conformance with the approved plans and specifications, approved change orders and applicable workmanship provisions of the State Building Code and Standards, as well as the structural engineer's design changes, approvals and verbal instructions. Our reports pertain to the material tested /inspected only. Information contained herein is not to be reproduced, except in full, without prior authorization from this office. If there are any further questions regarding this matter, please do not hesitate to contact this office. Respectfully submitted, CARLSON TESTING, INC. teven W. ach Project Manager SWL/rc cc: Zipper Zeman Associates Inc — Andrea F Kuehnel PE City of Tigard Building Division — Hap Watkins Stapley Engineering — Greg Leishman Bruce W Petersen Ncarb ESI Construction — Richard Brien OCT -14 -2008 TUE 04:45 PM CARLSON TESTING INC. . FAX NO. 5036840954 P. 01/02 • CARLSON TESTING, INC. Phone: 503 - 684-3460 /Fax 503 -684 -0954 PO Box 23814 Tigard, OR 97223 FAX TRANSMITTAL To: City of Tigard Attn: Building Department Fax: 503 - 624-3681 From: Carlson Testing, Inc. — Rachel Cuteri Date: October 14, 2008 Re: FINAL SUMMARY LETTER Total Pages: 2 This is the Final Summary Letter for: Project: Win= Foods Store #23 - Addition Permit # BUP2008 -00079 Please call if you have any questions. 503-684-3460. Thank You, Rachel Cuteri Office Assistant