Loading...
Plans 6 l (°2' 7 1 a. a. Annei; ca Fat• i t t so i-aA ce. Form 5a Project Name: TIGARD TRIANGLE BUILDING 1 Page: 1 LIGHTING - GENERAL 1. Interior Exceptions (Section 1313.1) ❑ No Interior Lighting. The building plans and specifications do not call for new or altered interior lighting. Skip to item 5, Exterior building Lighting - General, below. Exceptions ❑ Exceptions. 1. The building or part of the building qualifies for an exception from code lighting Discussion of qualifying requirements. Applicable code exception is number: exceptions in instructions section. 2. Lighting equipment that qualifies for an exception - in addition to general lighting and is separately controlled. Applicable code exception is number: Areas of the building and equipment that qualify for any exceptions: Plans /Specs Show compliance by including a NONE drawing sheet, detail number, and /or specification section and subparagraph. 2. Local Shut -off controls (Section 1313.3.1.1) o Complies. At least one local shut -off lighting control for every 2,000 square feet of lighted floor area and for all spaces enclosed by walls or ceiling height partitions. This control(s) is detailed in the building plans on drawing number: DRAWINGS E2.1, E2.2 ❑ Exception. The building or part of the building qualifies for an exception. Applicable code exception is Section 1313.3.1.1, Exception: Portions of the building that qualify: 3. Automatic Shutoff Controls (Section 1313.3.1.2) ❑ Not Applicable. Office floor area is not over 2,000 square feet of contiguous office floor area or permitted space is not over 5,000 square feet. No offices less than 300 square feet, meeting or conference rooms, or school classrooms. • Complies. All interior lighting systems are equipped with a separate automatic control to shut off lighting during unoccupied periods. Offices less than 300 square feet, meeting and conference rooms, and school classrooms shall be equipped with occupancy sensors that comply with Section 1313.3.1.2.1. Compliance details in plans /specs: DRAWINGS E2.1, E2.2 ❑ Exception. The building or part of the building qualifies for an exception. The applicable code exception is Section 1313.3.1,2, Exception: Portions of the building that qualify: 4. Daylighting Controls (1313.3.1.3) ❑ No classrooms or atriums with skylights or window to wall ratio greater than 50 %. O Complies. All classrooms and atriums with window to wall ratio greater than 50% and /or skylights are equipped with automatic daylight sensing controls, as required by Section 1313.3.1.3.1 and Section 1313.3.1.3.2. The daylight sensors specified comply with Section 1313.3.1.3.3. Compliance details in plans /specs: Exterior Build- 5. Exterior Lighting (Section 1313.5) ing Lighting 0 Complies. The plans do not call for use of incandescent or mercury vapor lamps for use on building exterior. is lighting directed to illuminate ❑ Exception. The building plans indicate luminaires with incandescent or mercury vapor lamps, but are the exterior of the building and specified for use in or around swimming pools, water features, or other locations subject to requirements adjacent walkways and of Article 680 of the 2002 National Electrical Code. loading areas with or without canopies. Clock Switches 6. Exterior and Canopy Lighting Controls (Section 1313.3.2) shall be astronomic (seasonal 9 Complies. The building plans and specifications include photoelectric and /or clock switches on all exterior correcting) type with separate lighting systems which are designed and programmed to extinguish lights when daylight is present, as programs for each day of the required by Section 1313.3.2. week and shall store energy to maintain timekeeping during power outages. 7. Interior Connected Lighting Power (Section 1313.4) YES Complies. The interior lighting power does not exceed the interior power allowance established in either the Tenant Space Method (Form 5b) or the Space -by -Space Method (Form 5c). �'?� a Tenant Space Method (Form 5b) r, Space-by-Space Method (Form 5c) 5 -1 Compliance with OSSC, effective 01/01/05 • Form 5b Project Name: TIGARD TRIANGLE BUILDING 1 Page: 1 INTERIOR LIGHTING POWER - Tenant Space Method Lighting (a) (b) (c) (d) Budget Occupancy/ Tenant or Building Type Floor Area Max Power Lighting Power Use Types (Table -13G) (sq ft) Density (W /ft Budget (W) See instructions for desc- Office lotion of occupancy types 48,667 1.0 48,667 Lighting Power 1. Total Interior Lighting Power Budget (Watts) for Building. 48,667 Budget Track Lighting 2. Total length of track lighting (ft) - Power 3. Line 2 multiplied by 37.5 Watts /ft 4. Total amperage of circuit breaker(s) serving track lighting (amps) 5. Voltage of circuit breaker serving track lighting (volts) 6. Maximum wattage of track lighting (multiply line 4 by line 5) 7. Track Lighting Power (lesser value of line 3 or line 6) 8. Track Lighting Power (line 7) 9. Total Interior Lighting Power from Worksheet 5b -1 (Sum of Column (m)) + 47,431 Building's 10. Total Adjusted Lighting Power (line 8 + line 9) = 47,431 Lighting Power 11. Does design meet budget? Line 10 must be no greater than line 1. YES g. 5-2 Compliance with OSSC, effective 01/01/05 Work: Project Name: TIGARD TRIANGLE BUILDING 1 Page: 3 LIGHTING SCHEDULE (a) (b) (c) (d) (e) (f) Lum Luminaire Is Luminaire ID Luminaire Lamp . Ballasts Power From Type Description ��� No. Description No. Description (watts) Table 5c A Fluorescent T8 - 4 foot ; 3 -F32T8 -ELECT NO 93W A 3 F32T8 1 Electronic Normal Output. RS 93 YES Fluorescent Rapid Start T8 2 foot 1 ,- 3 F 17T8 ELECT NO -53W B P 3 F17T8 1 Electronic Normal Output. RS 53 YES P le Compact Fluorescent Triple i' 1-CFM 18W /GX24q 2- ELECT -21 W C � P 1 CFM 18W /GX24q -2 1 Electronic 21 YES —6-TI Com o Fluorescent Triple , 2- CFTR26W /GX24q -3- ELECT -55W 2 CFTR26W /GX24q -3 1 Electronic 55 YES m a C2 ( 12 Volt Tungsten Halogen Lamps = 1 -50 watt lamp -MT -55W ,; 1 50 watt lamp 1 Magnetic Transformer 55 YES D Fluorescent T8 4 foot 2-F32T8-ELECT NO-62W 2 F32T8 1 Electronic Normal Output. RS 62 YES F 1 Compact Fluorescent Triple ,, _ 1- CFTR26W /GX24q -3 -ELECT 28W i 1 CFTR6W /GX24q -3 1 Electronic 28 YES G I Long Compact Fluorescent Twin - T5 (40W) 1- FT4OW /2G11 -ELECT NO-41W v 1' FT4OW /2G11 1 Electronic 41 YES Fluorescent T8 - 4 foot 2- F32T8 -ELECT NO-62W IE 7 ' 2 F32T8 I 1 Electronic Normal Output.. RS 62 YES X ! User Defined LED EXIT SIGN y 1 NA 1.7 NO I User Defined = CFU4 /27 = 4 27W • 1 Elect. Program Start , 160 . NO Compact Fluorescent Quad ;= 2- CFQ26W /G24d - - ELEC T 277V -54W 2 CFQ26W /G24d -3 2 277 V Electronic 54 YES K Fluorescent T8 - 4 foot V, 2- F32T8 -ELECT NO-62W J 2 F32T8 1 Electronic Normal Output. RS 62 YES • i 1 r ... _ LightingCompliance Form_rev3_7_07V3.3.xls (a) (b) (c) (d) (e) - (f) Lum Luminaire Is Luminaire ID. Luminaire Lamp Ballasts Power From, Type Description No. Description No. Description (watts) Table 5c _ q I - J I I I J 1 - 1 _ J - 1 J b, — 1 --1 J J — — _ I LightingCompliance Form_rev3_7_07V3.3.xls (a) (b) (c) (d) (e) (f) .. Lum Luminaire Is Luminaire ID Luminaire Lamp Ballasts Power From Type Description No. Description No. Description (watts) Table 5c I r� I ,N °` j Y, • • t. 1 J J il — I E J s ,,. ii i F I ii J — - - — 5-4 LightingCompliance Form_rev3_7_07V3.3.xls • J w Worksheet 5b -1 Project Name: TIGARD TRIANGLE BUILDING 1 Page: 4 INTERIOR LIGHTING POWER Space -by -Space Method Only , Skip to column (f) if using the Tenant Space Method • • (a) (b) (c) (d) (e) Lu ID (9) (h) f) (1) (k) from Quantity of . Room ID (do Space Type Space Lighting Power Worksheet Luminaires (or •Luminaire Lighting Room not leave any Area (Table 13 -H) Type Budget 5a Column lineal ft. for track Power Exempt Power Total Ltg. blanks) (fP) (enter space type only o nce per r oom) LPD, (b) x (d) (a) • lighting) (Watts) Fixtures (g) x (h) Power Each room 1ST FLOOR 25000 — . — A _zA 206 93 ❑ 19.158 23,102 must be 1ST FLOOR -- — B :J 23 '53 ❑ 1,219 — identified. 1ST FLOOR — - C 71 39 •21 ❑ 819 — Describe luminaires for each 1ST FLOOR — — • C2 J 2 55 ❑ 110 — individual room in 1ST FLOOR — F :'1 14 28 ❑ . 392 • — plans. 1ST FLOOR — — - D 6 62 ❑ 372 — 1ST FLOOR — — G =I 4 41 ❑ 164 — 1ST FLOOR . . — — E 4 62. ❑ 248 — Far track lighting 1ST FLOOR — — K '; 10 62 ❑ 620 , — enter lineal feet In 1ST FLOOR — — 62 ❑ - — column column (g) . • 2ND FLOOR 23667 — • A 1 207 .. - 93 ❑ 19,251 24,329 Column (k), enter 2ND FLOOR — — B =�I 21 - 53 ❑ 1,113 — sum of column q) 2ND FLOOR — — C 47 21 ❑ 987 — for each room only 2ND FLOOR — - — C1 4 10 55 ❑ 550 once at first entry ;=-I for the room . See 2ND FLOOR — , — • C2 .1 2 55 ❑ 110 — example in 2ND FLOOR _- - — D J 2 • 62 ❑ 124 - instructions. 2ND FLOOR , — — G =,1 4 . 41 ❑ • 164 — 2ND FLOOR — E 4 62 ❑ . 248 • — 2ND FLOOR — — H 0 - 160 ❑ . - - 2ND FLOOR __ — J =t 2 '54 ❑ 108 — 2ND FLOOR • - — K 27 62 ❑ 1,674 — _. — t1 ❑ - - J - ❑ — _ — -J - ❑ _. - n'l - ❑ - -- - . • _ ' J ❑ - - ❑ - - . - - - ❑ - _ - ❑ - _. J - ❑ - - - J ❑ - �«�� I - ❑ - _ .. - - I . , ❑ - - - =J - ❑ - - -- =1 ❑ - I ❑ - _ ❑ -. 1 ;=I - ❑ - - J - ❑ • - J - ❑ - - - - J - ❑ - • - . ' - 48,667 • Worksheet 5b-1 Total Budge t - Wksht 5b-1 Total Lighting Power (excluding exempt/track fixtures) 47,431 Other Pages Total Number of Additional Worksheet 5b �] List the additional worksheets nece- ssary to catalog all - - - ( - (m) (n) luminaires in - - building Lighting Power Budget: Space Proposed Buiding Lighting by -Space only (Total of Power (Total of column (k), Area Sgfl. (not required • Worksheet Number column (e)) excluding exempt/track) for Tenant Method) • 5b -1 - 47.431 • 48,667 5b2 . . 5b -3 • Sum of additional 5b worksheets 4 `,. 47,431 48,667 __..,�Y Total Budget (of all worksheets; • • 5-5 Compliance with OSSC, effective 01101(05