Plans (63) JOB NAME: Tigard Triangle Building #3 /Site Work CITY OF TIGARD
JOB ADDRESS: 11850 SW 67th, Tigard, OR BUILDING DEPARTMENT
DATE: August 8, 2006 13125 HALL BOULEVARD
MCE Project No.: 060891 TIGARD, OR 97223
SHEET 1 OF 1 Tigard Building Permit SIT2006 -00006
STRUCTURAL PLAN REVIEW #1
Plans Dated 5/10/06; Calculations Dated 6/26/06
Corr. Item Page No. Comments . Code Section
Made No.
1 Sheet S7.1 Masonry Submit calculations and.details with masonry 106.1.1
Calculations Pgs. 2, 14, etc. stress per element. Clarify conflict on
masonry stresses.
2 Sheet S9.1 Submit when or how often for type of work 1074
Special Inspection Program listed as periodic.
3 Sheet S7.3 calculations Submit soils report for values used for 106.1.1
seismic loading.
4 Calculations sheet 5 Submit calculations with safety factor on all 1806
walls.
5 Special Inspection Special inspection is required for concrete, 1704
reinforcing steel, embed plates, bolts and
masonry.
6 Structural Observation Structural observation is required for all 1709
concrete or masonry retaining and screen
walls.
7 General (shop drawing) Submit one set of reinforcing steel shop
drawings, which have been reviewed and
initialed by the Project Engineer, to be filed
with the -city of Tigard before placement.
8 General Approved resolution of the above items shall
be incorporated into submittal plans before a
permit will be issued. Submit four (4) sets of
revised plans to the city of Tigard.
� c
V �v JL �C
Ae4A 4 ,V ) \
AI