Correspondence (509) August 17, 2006 -�= CITY OF TIGMD OREGON Mildren Design Group, PC Dan Vasquez 1650 SW 105 Ave, Suite 175 Tigard, OR 97223. t ' RE: OPEN PARKING GARAGE — NEW BUILDING REVIEW F , Project Information ` ' 4 Building Permit BUP2006 -00207 Construction Type II! B Tenant Name: Pacific Northwest Property Occupancy' , ,s ` S -2 Address: 11850 SW 67 Ave. Oc tipant Load 248 +/- Area 49,419 sq ft Stories 2 The plan review was performed under the State of Oregon Structural Specialty Code (OSSC) 2004 edition and 2004 Oregon Fire Code as amended by TVF&R.,.The submitted plans are approved subject to the following conditions. 1. The structural review was reviewed and approved by Miller Consulting Engineers, August 16, 2006. (review doc. attached). 2. Special inspection is required for comah ete,, we n' forcing stee4 bolting, welded studs, embed plater bolts in concrete, masonry, soils, structural steel fabrication and erection, adhesive and expansion anchor installation, (as items listed on sheet A0.1 and Miller Consulting Engineers approved review letter)1be special inspection agency of record shall furnish inspection reports to the Engineer of,Record,- Afghan Associates, the General Contractor, and the City of Tigard, Building Division, attention Hap Watkins. All discrepancies shall be brought to the immediate attention of the general contractor for correction. The special inspector shall submit a final signed report stating whetlierthe work requiring special inspection was, to the best of the inspector's knowledge; in conformance with the approved plans and specifications and the applicable workmanship provisions of the code. 1701, 1704, 1705, 1707, 1708 OSSC 3. Structural Observations is required per section 1709 Oregon Structural Specialty Code (OSSC). The ownershall employ a registered design professional to perform structural observations as defined in Section 1702, OSSC. Structural observations is required for concrete foundation, retaining walls, reinforcing steel in shear walls and P/T slab, before concrete placement at second floor, placement of floor joist and before stressing P/T slab (as items listed on Miller Consulting Engineers approved review letter). Deficiencies shall be reported in writing to the owner and to the City of Tigard, Building Division, attention Hap Watkins. FYI The structural observations do not waive the framing inspection required by code. OSSC 1709 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772 4. Live Loads Posted: The live loads for which each floor has been designed to exceed 50 psf shall be conspicuously posted by the owner in that part of each story in which they apply, using durable metal signs, and it shall be unlawful to remove or deface such notices. The occupant of the building shall be responsible for keeping the actual load below the allowable limits. 1603.3 OSSC FIRE LIFE AND SAFETY / GENERAL ti 5. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Sec. 1011.1 OSSC Exit signs and the means of egress shall be illuminated at all times the building isloecupied,and s hall be provided with a second source of power that will provide 1 1/2 hours of illumination in of primary power loss. Sec 1006.2 & 3 OSSC FYI Additional exit signs may be requiredsby xhe city field inspector to clearly indicate the path of egress. "4/ -- , 7. The following uses and alterations are not permitted: 406.3.13 _OSSC 1. Vehicle repair work. , t 2. Parking of buses, trucks and similar vehicles. , 3. Partial or complete closing of required opening in exterio walls by tarpaulins or any other means. ; 4. Dispensing of fuel. 8. Fire extinguishers shall be selected, installed,and maintained in accordance with OFC 906 and NFPA 10. Extinguishers shall be located in conspicuous loons where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed i dicates the need for placement away from normal paths of travel. Sec. 906 OFC 9. Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of . extinguishers. "-` '\�� 10. Deferred submittals minimum fee shall be $200.00. This fee is in addition to the project plan review fee based on the total;project value. (OAR 918 -050 -0150) Documents for deferred submittal items shall be subinitted to the registered design professional in responsible charge who shall review them and fowaid them�to the building official with a notation indicating that the deferred submittal documents have been reviewed and been found to be in general conformance to the design of the building: The deferred submittal items shall not be installed until the design and submittal documents have been approved by the building official. Oregon Structural Specialty Code Section 106.3.4.2" Deferred Items: As noted on sheet A0.1 *Steel stairs Approved Plans: 1 set of approved plans, bearing the City of Tigard approval stamp, shall be maintained on the jobsite. The plans shall be available to the Building Division inspectors throughout all phases of construction. 106.3.1 OSSC Certificate of Occupancy: No building or structure shall be used or occupied until the Building Official has issued a certificate of occupancy 109.1 OSSC Premises Identification: Approved numbers or addresses shall be provided for all new buildings in such a position as to be plainly visible and legible from the street or road fronting the property. • When submitting revised drawings or additional information, please attach a copy of the endosed. of Tigard, Letter of Transmittal The letter of transmittal assists the City of Tigard in tracking ar d processing the documents. xk{ • -- - '2Z 11 .F � 1 Val Hemel, C 6 Senior Plans Examiner „et X`' r n c•� j _,ryw