Correspondence City of Tigard, Oregon 0 13125 SW Ha11 Blvd. • Tigard, OR 97223 • March 7, 2007 � i ; y Fjfi eR A �., t 0% fi t n 4 .a` 1 �+ t Cascade Fire Protection es 24023 NE Shea Ln. #110 L -TIAG �� ,R ® l�` Woodvillage, Or. 97060 ^ fV�. RE: STANDPIPES Permit Number BUP 2006 -00569 Construction Type: 2B Tenant Name: Tigard Triangle Occupancy Type: S2 Address: 11850 SW 67th Occupant Load: N/A Area: 49,414 Stories: 2 Sprinklers: NO Hazard: N/A The plan review was performed under the State of Oregon Structural Specialty Code (OSSC), 2004 edition; the Oregon Fire Code (OFC), 2004 edition and NFPA 72 Alarm Code. The submitted plans are approved subject to the following. General requirements Inspector shall verify that installation is complete and system is in compliance with NFPA 14 and contractor shall provide a record of completion at time of inspection. This system is a Non - required, non - complying, partial installation at this time. Manual Standpipe Systems. Where a manual standpipe system is provided, each hose connection shall be provided with a conspicuous sign that reads "MANUAL STANDPIPE FOR FIRE DEPARTMENT USE ONLY." NFPA 14 5.4.2 1) Standpipe system piping shall be protected from mechanical damage. NFPA 14 6.1.2.1* 2) To minimize or prevent pipe breakage where subject to earthquakes, standpipe systems shall be protected in accordance with NFPA 13, Standard for the Installation of Sprinkler Systems. NFPA 14 6.1.2.5 3) All valves shall be plainly marked to indicate the service that they control. NFPA 14 6.3.6.1.2.1 4) Where the standpipes are supplied from a yard main or header in another building, the connection shall be provided with a listed indicating -type valve located outside at a safe distance from the building or at the header. NFPA 14 6.3.6.2* 5) A listed check valve shall be installed in each fire department connection and located as near as practicable to the point where it joins the system.. NFPA 14 6.4.2 Phone: 503.639.4171 • Fax: 503.684.7297 • www.tigard - or.gov • TTY Relay: 503.684.2772 • 6) Fire department connections shall be located and arranged so that hose lines can be • attached to the inlets without interference from nearby objects, including buildings, fences, posts, landscaping, vehicles, or other fire department connections.. NFPA 14 6.4.5.1.1 7) Fire department connections shall be located not more than 100 ft (30.5 m) from the nearest fire hydrant connected to an approved water supply. NFPA 14 6.4.5.4* 8) Fire department connections shall be located not less than 18 in. (457 mm) nor more than 48 in. (1219 mm) above the level of the adjoining ground, sidewalk, or grade surface. NFPA 14 6.4.6 Approved Plans: 1 set of approved plans, bearing the City of Tigard approval stamp, shall be maintained on the jobsite. The plans shall be available to the Building Division inspectors throughout all phases of construction. 106.4.2 OSSC Premises Identification: Approved numbers or addresses shall be provided for all new buildings in such a position as to be plainly visible and legible from the street or road fronting the property. When submitting revised drawings or additional information, please attach a copy of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. Respectfully, Dan Nelson, Senior Plans Examiner