Correspondence (508) 60poci&-(;02-c July 26, 2006 ® 4, Val Henzel, Senior Plans Examiner 6 1-* City of Tigard v�- .. � o�. ■ c L 13125 SW Hall Blvd. G��� Cl' \v\S Tigard, OR 97223 S OP Re: Checklist Response Letter Triangle Commons - New Building (Building Two) Permit #: BUP2006 -00207 Dear Ms. Henzel, This letter is in response to your Permit Review Comments Letter (dated June 8, 2006) for the above - referenced project. The following items have been addressed in the revised drawing submittals (dated July 21, 2006) and have been itemized in this letter below - responses are in italics. STRUCTURAL 1. The structural review was completed by Miller Consulting. The plan review #1 dated June 1, 2006, was E- Mailed to Mildren Design Group for response (review doc. attached). A complete set of structural drawings has been included in this submittal in response to the review comments (see attached response letter from AAI Engineering). FIRE LIFE - SAFETY / GENERAL Cho (c ' ' "9 a Provide information on location of stand pipe. 70 S , S ' � � u SS j I See sheets PA2.1.1 and 2.1.2 for location of stand pipes. 3. Provide clarification on fire resistive rated structural member locations and assembly. O See sheet PA0.1- wall adjacent to property line is 8 -inch cast-in-place concrete which meets requirements of Table 601. . Provide clarification on exit stairway being 44" minimum. Stairways are 44 inches minimum - see details 5 and 6 on sheet PA4.1. 5. Provide clarification on height of building. S 00 S Provided - see "top o wall" spot elevations L4 ' h i '` S p f p on sheet PA2.2 . Q(� 6. Provide clarification on location of vehicle barriers. Vehicle barriers in accordance with OSSC406.2.4 have been provided - see details 3 /PA4.1, 6 /PA5.1, 9/S5.1 and 14/S5.2. Triangle Commons - New Building (Building Two) Review Comments Letter Response P:\ 101100. 02\ wp \LTR_COTchecksheetresponse.wpd Page 2 7. Deferred submittals such as Truss Joist Shop Drawings, TJI floor joists, Acoustical ceiling suspension system, Fire stopping, Intercom system, Specialty retaining walls, etc, will be charged a deferred submittal fee based on the valuation of the portion of the work being deferred. The minimum fee shall be $200.00. This fee is in addition to the project plan review fee based on the total project value. OAR 918- 050 -0150 "Documents for deferred submittal items shall be submitted to the registered design professional in responsible charge who shall review them and forward them to the building official with a notation indicating that the deferred submittal documents have been reviewed and been found to be in general conformance to the design of the building. The deferred submittal items shall not ve installed until the design and submittal documents have been approved by the building official. Oregon Structural Specialty Code Section 106.3.4.2" Deferred Items: As noted on sheet A0.1 *Steel stairs NOT PART OF THIS REVIEW: *Mechanical (HVAC) *Plumbing *Fire sprinkler *Electrical *Fire alarm *Low voltage End of Review Comments Please do not hesitate to contact me with any comments or questions. Cordially, Dan Vasquez Project Manager DAV /dav Attachments: • Revised set of drawings (full set). • Structural response letter with revised structural calculations (multiple pages). May 16, 2006 Miller Consulting Engineers 9570 Barbur Boulevard Portland, OR 97219 RE: PERSONAL SERVICES CONTRACT Project Information Tenant Name: Tigard Triangle - Parking Occupancy Type: S -2 Building Permit: BUP2006 -00207 Construction Type: IIB Address: 11850 SW 67 Occupant Load: NA To whom it may concern, Please review the accompanying structural plans for compliance with the Oregon Structural Specialty Code, 2004 edition. Enclosed are full size plan sheets, structural calculations and a copy of the permit application. Assess your review fee based on 33% of the total project plan review fee per the Personal Service Contract. Structural Review fee $3664.24 Fire & Life Safety fee $2254.92 Please contact the applicant for review questions and copy the City of Tigard with any correspondence. If you need additional information please call me at 503 - 718 -2759. Respectfully, Brian Blalock, Plans Examination Supervisor