Report !��,r 73- � 43( Construction Inspection & Related Tests C ar son Testing, Inc. Geotechnical Consulting P.O. Box 23814 Tigard, Oregon 97281 Special Inspection Phone (503) 684 -3460 FAX (503) 684 -0954 FINAL SUMMARY REPORT February 13, 1997 #96 -4814 PERMIT No.: BUP95 -0434 City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Re: Mercer Office Building X11565 SW 67th �, Tigard, Oregon Gentlemen: This is to certify that the items listed below are in accordance with Section 1701.3 of the Uniform Building Code. We have performed random /periodic special inspection at the contractor's request of the following items per our inspection reports only: Structural Masonry All inspections and tests were performed and reported according to the requirements of UBC Section 1701.3 and, to the best of our knowledge, the work was in conformance with the approved plans and specifications, approved change orders and applicable workmanship provisions of the Uniform Building Code and Standards, as well as the structural engineer's design changes and approvals. Our reports pertain to the material tested /inspected only. Information contained herein is not to be reproduced, except in full, without prior authorization from this office. If there are any further questions regarding this matter, please do not hesitate to contact this office. Respectfully sub itted, CARLSON TEST G INC. ( -__J Dougl W. Leach President mbh cc: Architects LA LBH Construction Construction In & Related Tests Carlson Testing, Inc. Geotechnical Consulting P.O. Box 23814 Tigard, Oregon 97281 Phone (503) 6843460 FAX (503) 684 -0954 March 13, 1996 095- 4814.CTI Permit No. BUP95 -0434 FIELD INSPECTION REPORT DATES COVERED: March 12, 1996 PROJECT: )`Mercer Office Building ADDRESS: /1S(,a11 .535 SW 67th Avenue -- Tigard, OR INSPECTOR: D. Whitehead 003- 12 -96: CTI representative was on site at 10:30 AM for rebar inspection and full time masonry grout placement at final lift topping, except at entrance. Entrance will continue up. All rebar was correct in placement as per plans supplied by Contractor. Masonry contractor agitated each cell with a rod to consolidate the grout. This method proved to be satisfactory. ♦ 423,1.400 Our reports pertain to the material tested /inspected only. Information contained herein is not to be reproduced, except in full, without prior authorization from this office. If there are any further questions regarding this matter, please do not hesitate to contact this office. Respectfully submitted, CARLSON TESTING, NC. Douglas W. Leach President DW:ecp cc: Architects LA City of Tigard LBH Construction Construction Inspectron & Related Tests Carlson Testing; Inc. Geotechnical Consulting iEPORT OF j ' . 1. t::?I'1Ci` 1 .. T I_ TEST SPECIMENS . P.O. Box 23814 Tigard, Oregon 97281 - est Methods: AS C1.72/C1231/C39/C31/C1064/C143 Phone (503) 684 - 3460 FAX # 684 -0954 )ate Molded: , 19 Job No. Permit No: AR C H I .'_ EC f aient: 7 L_ i` , 'roject: MERCER O i= F I C E BUILDING ddress: fi sW 67TH AVENUE TIGARD OR 1 / / c. 5 : ontractor. LBH CONS 1 R U C T I O iV Suh Contractor: • ;oncrete Supplier: BEST MIX CONCRETE Truck No. 97 Ticket No. ;ast By: D . V 1 C K Cu. Yds. 5 1/2 Load No. SUNNY - OVERCAST 45 39 Veather: Temp. High: Temp. Low: FooTING CONT:[Nuous ocation of Placement: Test 5v Concrete Temp: 60 Strength Requirement: 3000 PSI @ 28 days Slump j _ 1/2 Cement Type 1 30BA4P18 3/4" Aix No /No. Sacks Air Content Max. Aggregate admix. Amount: Brand: Admix. Amount: Brand: Set Test@ Register Date Date Total Area Unit Report Tested rea No. Days Number Rec'd Test Load PSI Na By 7 9169 01/18 01/24 67,730 28.23 2400 ` ra 28 9119 01/1 02/14 28 9169 01/18 02/14 remarks CC : CI TY OF TIGARD - LBH CONS T; UCI:[ON nformation contained herein is not to be reproduced; except in full without pnor authonzation from,this office „ 3 ;:. ' . Construction In & Related Tests C arlson Testing, Inc. Geotechnical Consulting P.O. Box 23814 Tigard, Oregon 97281 Phone (503) 684-3460 FAX (503) 684 -0954 January 19, 1996 ♦96- 4814.CTI Permit No. BUP95 -0434 FIELD INSPECTION REPORT DATES COVERED: January 17, 1996 PROJECT: Mercer Office Building 05-6'S ADDRESS: SW 67th Avenue - Tigard, OR INSPECTOR: D. Vick +01- 17 -96: CTI representative noted a 3000 psi concrete was placed in continuous footings. One set of (3) cylinders were made. Slump was 3 1/2 ", temperature was 60 °. 0 409,1,100 Our reports pertain to the material tested /inspected only. Information contained herein is not to be reproduced, except in full, without prior authorization from this office. If there are any further questions regarding this matter, please do not hesitate to contact this office. Respectfully submitted, CARLSON TESTING, INC D._ sl Douglas W. Leach President DV:eah cc: Architects LA City of Tigard LBH Construction Construction Inspection & Related Tests Carlson Testing, Inc. Geotecnnical consulting P.O. Box 23814 Tigard, Oregon 97281 Phone (503) 684-3460 March 7, 1996 FAX (503) 684 -0954 +95 4814.CTI Permit No. BUP95 - 0434 FIELD INSPECTION REPORT DATES COVERED: March 4, 1996 PROJECT: Mercer Office B uilding ' 1ST ADDRESS: SW 67th Avenue -- Tigard, OR INSPECTOR: D. Vick +03 CTI representative arrived at jobsite at 12:40 and was informed that the City Inspector had already inspected reinforcing in 8" CMU walls and had been approved. CTI representative observed the grout pour of the perimeter wall up to 6 1/2'. One set of (3) grouted prisms were made. A 6 sack kurtz mix was placed. Mix #883, approximately 8 1/2 yards. • 409,1,400 Our reports pertain to the material tested /inspected only. Information contained herein is not to be reproduced, except in full, without prior authorization from this office. If there are any further questions regarding this matter, please do not hesitate to contact this office. Respectfully submit ed, C' - L / /.N T STIN % C. J 'o •las . Leach Pr- . sident 'V:ecp cc: Architects LA City of Tigard LBH Construction Construction Inspection Related Tests Carts ®n Testing, Inc. & Geotechnical Consulting REPORT OF 6X12 CONCRETE TEST SPECIMENS P.O. Box 23814 ASTM C172/C1231/C39/C31/C1064/C143 Tigard, Oregon 97281 Test Methods: Phone (503) 684 -3460 FAX # 684 -0954 01/17 96 96 -4814 8UP95 -0434 Date Molded: , 19 Job No. Permit No: Client: ARCHITECTS LA Project: MERCER OFFICE BUILDING X1535 SW 67TH AVENUE TIGARD OR / / 37a Address: LBH CONSTRUCTION Contractor: Sub Contractor: BEST MIX CONCRETE 97 Concrete Supplier: Truck No. Ticket No. Cast By: D . V [ C k Cu. Yds. h 1/2 Load No: SUNNY OVERCAST 45 39 Weather: Temp. High: Temp. Low: FOOTING CONTINUOUS Location of Placement: 2:50 60 Test Time: Concrete Temp: 3000 28 3 1/2" I Strength Requirement: PSI @ days Slump Cement Type 30BA4P18 3/4" Mix NoJNo. Sacks Air Content Max. Aggregate Admix. Amount: Brand: .Jldmix. Amount: Brand: Set Test@ Register Date Date Total Area Unit Report Tested No. Days Number Rec'd Test Load PSI No. By 7 9169 01/18 01/24 67,730 28.23 2.400 AS 28 9169 01/18 02/14 107,970 28.26 3820 AS 28 9169 01/18 02/14 108,360 28.26 3830 AS , Remarks: - cc: CITY OF TIGARD LBH CONSTRUCTION LABORATORY MANAGER Reviewed By Our reports pertain to the material tested /inspected only. Information contained herein is not to be reproduced, except in full, without prior authorization from this office.