Correspondence (141) 42 7/18(00 LAT— A
6of 2w / -v '(
s. SHEATHING SCHEDULE: GREEN OFFICE BUILDING
Roof Sheathing: 1/2" plywood (32/16) or APA rated sheathing
(Particle board, oriented strand board,
flake board, or waferboard, etc)
With 10d COM nails at 6" o/c all panel edges
And 10d COM nails at 12" o/c field.
(Edges may be unblocked for shear) (240/180)
Floor Sheathing: 3/4" plywood (48/24) or APA rated sheathing
With 10d com nails at 6" o/c all panel edges
And 10d com nails at 10" o/c field.
(Edges must be blocked for shear) (285/215)
Exterior Walls: 5/8" GYPSUM SHEATHING (Type "X ")
(Typical) With No.11 gage , 1 -7/8" long, 7/16" head,
diamond point, galvanized nails at 7" o/c 1/18/00
at all studs and plates. 6�i Sr o v� 7
Interior Walls: 1/2" plywood (24/0) or APA rated sheathing
(Third Floor) With 8d com nails at 3" o/c all panel edges
And 8d com nails at 12" o/c field.
All edges must•be blocked. (490)
Interior Walls: 1/2" plywood (24/0) or APA rated sheathing
(Second Floor) With 10d com nails at 2" o/c all panel edges
And 10d com nails at 12" o/c field.
All edges must be blocked. (770)
Interior Walls: 1/2" plywood (24/0) BOTH SIDES OF WALL
(First Floor) With 8d com nails at 3" o/c all panel edges
And 8d com nails at 12" o/c field.
All edges must be blocked. (980)
Note: Provide 4x6 intermediate studs at all vertical panel edges at First and Second
Floor walls.
Anchor Bolts: P.T. 2x6 (min) sill plates with 5/8" dia -
--- :r
(Exterior) X 10" Anchor Bolts at 48" o /c. _� � 4'
'_• �' 9381PE 1 " . `._
Anchor Bolts: P.T. 2x6 (min)•sill plates with 3/4" dia
(Interior) X 14 t, 16" Anchor Bolts at 16 o /c.
OREGON
;� ✓G.. 22 , �1
1 •
EYP DATE 12131/6E_