Correspondence (143) 10/30/02 WED 14:55 FAX 5036243681 CITY OF TIGARD BLDG DEPT Z001 * ** TX REPORT * ** ********** *** * * * **** TRANSMISSION OK TX /RX NO 0039 CONNECTION TEL 5032457710 CONNECTION ID ST. TIME 10/30 14:53 USAGE T 01'29 PGS. SENT 5 RESULT OK FAX TRANSM!TTAL 4 1i1l 1111 Date October 30, 2002 Number of pages including cover sheet 5 To: Roder From: Gary Lampella Co: Ankrom Moisan Co: City of Tigard Fax #: (503) 245 -7710 Fax #: (503) 684 -7297 Ph #: (503) 639 -4171, Ext. 2448 Ro• er I received a letter from Ba and Mentrum on 10/22/01 and called him that da • Sent a letter to Joe Green on 10/23/01 and received res•onse on 12/11/02 ident" in. Gary Darling as the engineer of record. Received another letter on 10/4/02 saving DL Design, Inc. is the engineering firm of record. As ou can see from m letter I was • rett clear on what the res • onsibilities of the architect or engineer of record are. We still need to iron out the issue of Mentrum Architecture's stamped drawings and whom is realy responsible. SUBJECT: FAX TRANSMITTAL * #/ � i �"NI� �1 � ' . 11141%0411 ' aimum . 1 1 Date October 30, 2002 Number of pages including cover sheet 5 To: Roger From: Gary Lamella Co: Ankrom Moisan Co: City of Tigard Fax #: (503) 245 -7710 Fax #: (503) 684 -7297 Ph #: (503) 639 -4171, Ext. 2448 Roger, I received a letter from Bayard Mentrum on 10/22/01 and called him that day. Sent a letter to Joe Green on 10/23/01 and received response on 12/11/02 identifying Gary Darling as the engineer of record. Received another letter on 10/4/02 saying DL Design, Inc. is the engineering firm of record. As you can see from my letter, I was pretty clear on what the responsibilities of the architect or engineer of record are. We still need to iron out the issue of Mentrum Architecture's stamped drawings and whom is realy responsible. SUBJECT: MESSAGE: I:\ENG\FAX.DOT • ( t • ( 4I November 23, 2002 CITY' OF TIGARD OREGON Roger Superneau Ankrom Moisan Associated Architects 6720 SW Macadam, Suite 100 Portland, OR 97129 Re: Revised Exiting and Alternate Methods of Construction Green Office Building, 11560 SW 67 BU P2001 -00061 Dear Mr. Superneau, We have reviewed the revised exiting plans for the above referenced project as well as the request for alternate methods of construction. Based on the structural conditions of moving the stairways and the stage of construction this project is in, we are approving the alternates subject to the following conditions. This review was performed under, the provisions of the State of Oregon Structural Specialty Code (OSSC), 1998 edition and the International Building Code (IBC), 2000 edition. • The current configuration of the exit enclosures does not meet the provisions of OSSC Section 1004.2.4. The overall diagonal of the building is 114 feet requiring the exits to be separated a distance of 57 feet. They are currently 32.5 feet apart. The revised plans show one -hour rated exit passageways on all three floors at the north end of the building. This puts the required exits approximately 38 feet apart. You have requested Exception 2 of IBC Section 1004.2.2.1 be utilized as an alternate which allows the exit separation to be reduced to one -third the overall diagonal when the building is equipped throughout with an automatic sprinkler system. One -third of 114 feet is 38 feet. We understand that an automatic sprinkler system will be installed. The IBC is a nationally recognized document containing similar provisions as the OSSC. In accordance with OSSC Section 104.2.8, for alternates, we believe this provides an equal degree of safety and this request is hereby approved. • OSSC Section 1005.3.4.4 states that openings into exit passageways shall be limited to those necessary for egress from normally occupied areas. The revised plans show the main floor restrooms opening into the main floor exit passageway. Due to the hardship of reconfiguring the under -slab plumbing and to minimize the possibility of compromising the structural footings, you have requested that we approve an alternate for the existing configuration. Your proposal is to construct the walls separating the restroom and exit passageway with 2 -hour fire - resistive construction with 90- minute doors. These two restrooms contain only 1 water closet and 1 lavatory each and will only be used by a single occupant at any given time. In accordance with OSSC Section 104.2.8 for alternates methods of construction, we believe this provides an equal degree of safety and this request is hereby approved. 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503).684 -2772 The submitted revised drawings by Ankrom Moisan Associated Architects are approved subject to the following conditions. 1. All doors opening into the exit passageways and exit enclosures shall be provided with doors with a maximum transmitted temperature end point not exceeding 450 F above ambient at the end of 30 minutes of the fire exposure specified in UBC Standard 7 -2. OSSC 1005.3.3.5, 1005.3.4.4. 2. Penetrations into or through exit passageways are prohibited except for those serving the exit passageway such as sprinkler piping, standpipes, and electrical conduit terminating is a listed box not exceeding 16 square inches. OSSC 1005.3.4.4. 3. Penetrations into or through exit enclosures are prohibited except for those serving the exit enclosure such as ductwork and equipment necessary for independent stairway pressurization, sprinkler piping, standpipes, and electrical conduit terminating is a listed box not exceeding 16 square inches. OSSC 1005.3.4.4. 4. Automatic - closing fire assemblies shall have one heat - actuating device installed on each side of the wall.at the top of the opening and one on each side of the wall at the ceiling height where the ceiling is more than 3 feet above the top of the opening. OSSC Section 713.2, 713.6.1 5. There shall not be enclosed usable space under stairways or ramps in an exit enclosure. The open space under such stairways shall not be used for any purpose. OSSC Section 1005.3.3.6. 6. Exit signs shall be provided and illuminated in accordance with OSSC Sections 1003.2.8 and 1003.2.9. • 7. A copy of the approved plans shall be kept on site at all times and made available for inspection purposes. OSSC 106.4.2. If you have any questions or concerns, please contact me at (503) 718 -2448. Sincerely, Gary Lampella Building Official c. Joe Green Mark Hoyt Hap Watkins, Supervising Inspector Jim Hendryx, Director of Community Development File