Specifications /Gl - 0 CO 10 Engineering INlooli Inc PO Box 23784 Tigard, Oregon 97281 • Phone: (503) 620 -2086 • Fax: (503) 684 -3636 SEISMIC BRACING AND CONSTRUCTION REQUIREMENTS FOR THE SUSPENDED ACOUSTICAL TILE CEILING SYSTEM FOR: TVF &R COMMAND AND BUSINESS OPERATIONS CENTER 11945 SW 70TH AVE. TIGARD, OREGON 'RECEIVED FF . D PRO (& O PZc d - e s Xi7C City of Tigard s PIG 12 ZM FF � ° � Ap • oved Plans � 7 •8PE r CITY OFTIGARD N By �,r., • Date 11311a 1VISIO. BUILDING D ` �o• 41, k 70 iE - v/ 15 2CP x , \ , ` \ . T U 9 OFFICE COPY EXPIRES : 6/ 30/ • tr FPi>i -9 CLIENT : ANNING— JOHNSON COMPANY JOB NO.: 100505 PREPARED BY : SET CHECKED BY : . DATE : 6 -1 -10 PAGE OF 13 , ® Project: TVFtR COMMAND AND BUSINESS OPERATIONS CENTER Page: 2 Client: ANNING JOHNSON By: SET ENGINEERING, INC. Job No.: 100505 Date: 6-1 -10 DESCRIPTION / CONSTRUCTION REQUIREMENTS: CODE: 2006 IBC (2007 OSSC) TYPE OF GRID: ARMSTRONG 7501 MAIN RUNNERS W/ XL 7590 CROSS TEES HEAVY DUTY SYSTEM STRUCTURE ABOVE CEILING: 1.) CONCRETE OVER METAL DECK 2.) 20 GA METAL DECKING OVER OPEN -WEB STEEL JOISTS (SEE DETAILS "A1" AND "A2" FOR MORE INFO.) COMPRESSION STRUTS: 1 5/8 "- 20 GA STUD W/ 1 1/4" FLANGES UP TO 8' -0" TALL (SEE DETAILS "B1" AND "B2" FOR MORE INFO.) FASTENERS FOR SPLAY WIRES: 1.) HILT! 3/8" KWIK BOLT TZ W/ CEILING CLIP 2.) WIRES TIED TO STEEL JOISTS (SEE DETAILS "B1" AND "B2" FOR MORE INFO.) DIAGONAL WIRE SPLAYS: 12 GA STRUT AND SPLAY SPACING: 1ST FLOOR CEILINGS 12' -0" x 17-0" EACH WAY AND 6 -0" FROM WALLS OR SEPARATION JOINTS. 2ND & 3RD FLOOR CEILINGS 10' -0" x 12' -0" EACH WAY AND 5' -0" OR 6 -0" FROM WALLS OR SEPARATION JOINTS, RESPECTIVLEY. NOTES: 1.) ALL ELEMENTS OF THE SUSPENDED CEILING SYSTEM NOT SPECIFICALLY ADDRESSED WITHIN THESE CALCULATIONS ARE TO BE INSTALLED PER THE REQUIREMENTS OF THE NORTHWEST WALL & CEILING BUREAU TECHNICAL BULLETIN 401, FOUND AT: www.nwcb.org IN REFERENCE TO ASCE 7 -05 SECTION 13.5.6.2.2: 2.) UNLESS PERIMETER DETAILS PER THE ATTACHED DETAIL "C" ARE USED OR OTHER APPROVED METHOD AND /OR DEVICES ARE USED AT CEILING PERIMETER, THE WIDTH OF THE PERIMETER CLOSURE ANGLE SHALL NOT BE LESS THAN 2.0 INCHES. IN EACH ORTHOGONAL HORIZONTAL DIRECTION, ONE END OF THE CEILING GRID SHALL BE ATTACHED TO THE CLOSURE ANGLE. THE OTHER END IN EACH HORIZONTAL DIRECTION SHALL HAVE A 3/4 IN. CLEARANCE FROM THE WALL AND SHALL REST UPON AND BE FREE TO SLIDE ON A CLOSURE ANGLE. AT ATTACHED SIDES USE 1/8" 5052 ALUM. RIVETS FROM GRID TO ANGLE. CLOSURE ANGLE SHALL BE ATTACHED TO WALL STUDS AT 16" O.C. W/ #6 x 1 1/4" SCREWS. 3.) FOR CEILING AREAS EXCEEDING 2500 S.F., A SEISMIC SEPARATION JOINT OR A PARTITION WALL THAT EXTENDS THRU THE CEILING THAT BREAKS THE CEILING UP INTO 2500 S.F. AREAS SHALL BE PROVIDED. EACH CEILING AREA SHALL BE PROVIDED WITH CLOSURE ANGLES IN ACCORDANCE WITH NOTE #1 AND LATERALLY BRACED AS DESCRIBED IN THESE CALCULATIONS. 9025 SW Center Street - PO Box 23784 Tigard, Oregon 97281 • Phone: (503) 820 -2088 Fax: (503) 884 -3636 ® Project: 7VF4R COMMAND AND BUSINESS OPERATIONS CENTER Page: 3 Client: ANNINCz JOHNSON By. SET ENGINEERING, INC. Job No.: 100505 Date: 6 -1 -10 STATEMENT OF SPECIAL INSPECTIONS The following components and construction require special inspection: 1.) Periodic special inspection is required for the Hilti Kwik. Bolt TZ anchors noted in detail B1. Inspections shall be per the requirements of ICC ESR -1917, section 4.4. 2.) Special inspection is required for power driven fasteners installed in concrete over metal decking applications, as noted in detail Al. This inspection shall be in the form of pull testing as described in section V -g of the Oregon Statewide Code Interpretation No. 2007 OSSC Section 1613.1. Periodic shall be defined as follows: Inspection by the special inspector of the specified material and /or system described above prior to commencement of the work, at some point during installation, and upon completion of the work. These intervals shall apply to each differing ceiling system. All non - conforming work shall be corrected by the contractor prior to other related work proceeding and covering the subject work. The special inspector shall be a qualified person who has demonstrated competence, to the satisfaction of the building official, for inspection of each of the specified materials and /or systems described above. 9025 SW Center Street - PO Box 23784 Tigard, Oregon 97281 • Phone: (503) 820 -2088 Fax (503) 884 -3838 ® ® Project: T\F4R COMMAND AND BUSINESS OPERATIONS CENTER Page: 4 Client: ANNING JOHNSON By. SET ENGINEERING, INC. Job No.: 100505 Date: 6 -1 -10 CONCRETE OVER METAL DECK ( B.O.) d ° 1 I/8" MIN. d d ° a Q ° 4 ° Q A ° °I a HILTI X -CW X -C 27 CEILING WIRE ASSEMBLY (E5R -2892) OR APPROVED EQUAL. (SEE NOTE BELOW FOR 12 GA HANGER WIRES 9 4' -0" FURTHER REQUIREMENTS) O.C. ALONG MAIN RUNNERS W/ (3) TIGHT TURNS AT CONNECTIONS ARMSTRONG 7501 HEAVY DUTY MAIN RUNNER 9 72" D.G. ARMSTRONG XL7590 CROSS TEES 9 24 " O.G. 11-9 Q � Q j SI_p Q �L NOTE: SEE STATEMENT OF SPECIAL INSPECTIONS REGARDING PULL TESTING OF POWER DRIVEN FASTENERS INTO CONCRETE OVER METAL DECK TYP. CEILING CONSTRUCTION Al AT CONCRETE STRUCTURE (FLOORS 1 & 2) 9025 SW Center Street - PO Box 23784 Tigard, Oregon 97281 • Phone: (503) 620 -2086 • Fax: (503) 684 -3636 Kg El ® Project: TVFtR COMMAND AND BUSINESS OPERATIONS CENTER Page: S Client: ANNING JOHNSON By SET ENGINEERING, INC. Job No.: 100505 Date: 6 -1 -10 20 GA METAL ROOF DECKING (5.0.) A • I -LAG 150 SD EYE LAG SCREW (ER -5361) 12 GA HANGER WIRES m 4' -0" O.C. ALONG MAIN RUNNERS W/ (3) TIGHT TURNS AT CONNECTIONS ti ARMSTRONG 1501 HEAVY DUTY MAIN RUNNER 6 4S" O.G. ARMSTRONG XL1590 CROSS TEES 6 24 " D.C. o- a -, 1 TYP. CEILING CONSTRUCTION A2 AT METAL DECK STRUCTURE (FLOOR 3) 9025 SW Center Street - PO Box 23784 Tigard, Oregon 97281 • Phone: (503) 620 -2086 • Fax: (503) 684 -3636 NNIC01 Project: TVF4R COMMAND AND BUSINESS OPERATIONS CENTER Page: Client: ANNING JOHNSON By SET ENGINEERING, INC. Job No.: 100505 Date: 6 -1 -10 CONCRETE OVER 3/8 "4) I -IILTI KWIK BOLT TZ METAL DECK (B.O.) W/ 2 EMBEDMENT u d 4 Q 1" MAX -� a -oat I . a a wl a a REMOVE STUD FLANGES AND- BEND WEB ONTO SLAB. ATTACH WEB W/ 0.138 "4 x 1 1/4" PD F. 4 1/2" MIN. LI "x1 "x1 "WIDEx16GA COMPRESSION POST MIN. W/ 1 /40 1-10LE AT WIRE 1 BIB" - 20 GA STUD 4 1/16 "4' HOLE AT BOLT MAX. HEIGHT = 8' -0" 12 GA DIAL. SPLAY WIRES AT 45° MAX. TO PLANE OF CEILING. (4) WIRES TOTAL AT 90° TO EACH OTHER IN PLAN. (ONLY (2) SPLAYS AIRE REQ'D WHERE NOTED IN CORRIDOR CEILING PLANS) REMOVE STUD FLANGES AND INSTALL TIGHT TO TOP OF MAIN RUNNER. ATTACH WEB TO MAIN W/ (2) 4 13 SCREWS 0 0 o 0 L , o O O O O 11 O 2" MAX. TO HEAVY DUTY MAIN RUNNER OPPOSING SPL RE 1 4 CROSS TEE SEE PAGE 2 FOR BRACE SPACING REQUIREMENTS SEISMIC BRACE DETAIL B1 AT CONCRETE STRUCTURE 9025 SW Center Street - PO Box 23784 Tigard, Oregon 97281 • Phone: (503) 620 -2086 • Fax: (503) 684 -3836 MN 1 ice ® Project: TVFtR COMMAND AND BUSINESS OPERATIONS CENTER Page: 1 Client: ANNING JOHNSON By. SET ENGINEERING, INC. Job No.: 100505 Date: 6 -1 -10 i i + -- . / ' 20 GA METAL ROOF DECKING (B.O.) / 11 OPEN WEB STEEL REMOVE STUD FLANGES AND-' JOISTS (B.Q.) BEND WEB ONTO DECKING. ATTACH WEB W/ (2) •8 SCREWS. _IL WIRE TIED TO TOP CHORD OF JOIST W/ (3) TIGHT TURNS. WIRE MAY BE TIED TO BOT. CHORD WHEN WIRE IS PARALLEL TO JOIST IN PLAN. COMPRESSION POST 15/8 " -20 GA STUD 12 GA DIAL. SPLAY WIRES MAX. HEIGHT = 8' - 0" AT 45° MAX. TO PLANE OF CEILING. (4) WIRES TOTAL AT 90° TO EACH OTHER IN PLAN REMOVE STUD FLANGES AND INSTALL TIGHT TO TOP OF MAIN RUNNER ATTACH WEB TO MAIN W /(2)*5 SCREWS '} +I 1 1 o ..• L J O O 2" MAX. TO I HEAVY DUTY MAIN RUNNER OPPOSING I 1 SPLAY WIRES 4 /f CROSS TEE SEE PAGE 2 FOR BRACE SPACING REQUIREMENTS SEISMIC AC TAIL B2 AT METAL DECK /STEEL JOIST STRUCTURE 9025 SW Center Street - PO Box 23784 Tigard, Oregon 97281 • Phone: (503) 620 -2086 • Fax: (503) 684 -3636 ® ® Project: TYF4R COMMAND AND BUSINESS OPERATIONS CENTER Page: 8 Client: ANNING JOHNSON By SET ENGINEERING, INC. Job No.: 100508 Date: 6 -1 -10 MIN. *6 x 1 1/4" SCREW FROM WALL ANGLE TO EA. WALL STUD. 24" O.G. MAX. f 8" MAX.1 8" MAX. /E r 4 1/8" CLOSURE ANGLE 4 °%4 \ � trP. HANGER �. ° a .4% WIRE ® „ .o \ J 0, "6 SCREW IN SLOT (TIGHTENED) I/8 "4 5052 ALUMINUM POP RIVET AT EA. GRID MEMBER TO WALL ARMSTRONG BM CLIP ANGLE REF: ICC ESR -1308 0 ATTACHED WALL 2 ATTACHED WALL OPTION 1 OF 2 _ OPTION 2 OF 2 ARMSTRONG BER2 8" MAX. NOTE: CLIP IN EACH ORTHOGONAL HORIZONTAL REF: ICC ESR -1308 DIRECTION ONE END OF THE CEILING /— SHALL BE ATTACHED TO THE i CLOSURE ANGLE PER DETAIL I OR 2. THE OTHER END IN EACH � � ° ‘0 ORTHOGONAL D IRECTION SHALL BE 3/4" ° Q. FREE TO SLIDE ON THE CLOSURE ANGLE AS PER DETAIL 3. REF: ° \� ICC -ESR 1308 FOR ADDITIONAL INFO. 1/8" CLOSURE GRID MEMBER ANGLE 0 UNATTACHED WALL 0 PERIMETER DETAILS 9025 SW Center Street - PO Box 23784 Tigard, Oregon 97281 • Phone: (503) 620 -2086 • Fax: (503) 684 -3636 • Project: TVFdR COMMAND AND BUSINESS OPERATIONS CENTER Page: Ci Client: ANNINCs JOHNSON By: SET ENGINEERING, INC. Job No.: 100505 Date: 6 -1 -10 LATERAL FORCE: AT 1ST FLOOR CEILINGS REF: ASCE 7 -05, SECTION 13.3 Using ASD load combination including 0.7E, where E = Q = F Ref: a =,:.:::- ;1::00: [T13.5 -1] Sp 0730 From project specifications or calculated using USGS Seismic Ground Motion Calculator with assumed Site Class = D W O 41)0 psf [13.5.6.1] I p = 1:50 [13.1.3] Rp 2:50 For bracing components except anchors in concrete. [T13.5 -1] R p = 1.:00 For anchors in concrete not governed by the strength [13.4.2] of a ductile steel element or not complying w/ ACI 355.2. z h 36s00ft For all bracing components except anchors in concrete: F ( 0. 7)( 0 .4)a /(R /I +2(z/h)) = 0.57 psf [13.3 -1] For anchors in concrete not governed by the strength of a ductile steel element or not complying w/ ACI 355.2: F = ( 0. 7)( 1. 3)( 0 .4)a /(R /I +2(z/h)) = 1.86 psf [13.3 - 1],[13.4.2] FpMAX = (0.7)1.6SpslpWp = 4.91 psf [13.3 -2] F pMJN = (0.7)0.3S = 0.92 psf [13.3 -3] USE F = 0.92 psf USE F = 1.86 psf Spacing of struts and splays, x -dir 12 ft r' Spacing of struts and splays, y -dir = ft v Tributary area = (x- dir)(y -dir) = 144 sq. ft. Lateral force at each seismic brace location: F pBRACE = F x Tributary area = 132 Ibs Lateral force for concrete anchor design (when applicable): Fp2 BRACE = F x Tributary area = 268 Ibs, shear and tension in anchor Compression force in struts with splays at 45 degrees: F'POST = FpBRACE x Tan 45° = 132 Ibs Splay wire anchor loading: p 45° 1 P =F x Tan 45°F 9025 SW Center Street - PO Box 23784 Tigard, Oregon 97281 • Phone: (503) 620-2088 Fax: (503) 684 -3838 ® ® Project: Tvf4R COMMAND AND BUSINESS OPERATIONS CENTER Page: 10 Client: ANNING JOHNSON By. SET ENGINEERING, INC. Job No.: 100505 Date: 6 - l - I0 LATERAL FORCE: AT 2ND FLOOR CEILINGS REF: ASCE 7 -05, SECTION 13.3 Using ASD load combination including 0.7E, where E = Q F Ref: a P = 1; 00 [T13.5 -1] SOS = 0:730 From project specifications or calculated using USGS Seismic Ground Motion Calculator with assumed Site Class = D W 4 00`psf [13.5.6.1] I = 1::50 [13.1.3] R 2.50; For bracing components except anchors in concrete. [T13.5 -1] Rp 1:00 For anchors in concrete not governed by the strength [13.4.2] of a ductile steel element or not complying w/ ACI 355.2. z h = 36:DO ft For all bracing components except anchors in concrete: F = ( 0. 7)( 0 .4)a /(R /I +2(zlh)) = 1.06 psf [13.3 -1] For anchors in concrete not govemed by the strength of a ductile steel element or not complying w/ ACI 355.2: F 0. 7)( 1. 3)( 0 .4)a /(R /I +2(zlh)) = 3.45 psf [13.3 - 1],[13.4.2] F (0.7)1.6S = 4.91 psf [13.3 -2] F pMIN = (O.7)0.3S = 0.92 psf [13.3 -3] USE F = 1.06 psf USE F = 3.45 psf Spacing of struts and splays, x -dir = 1:0ft v Spacing of struts and splays, y -dir 12ft v Tributary area = (x- dir)(y -dir) = 120 sq. ft. Lateral force at each seismic brace location: FPBaACE= F Tributary area = 128 Ibs Lateral force for concrete anchor design (when applicable): F PZ BRACE = F x Tributary area = 415 Ibs, shear and tension in anchor Compression force in struts with splays at 45 degrees: W 6 {Z`JT GA rart- P POST = FPBRAcE x Tan 45° = 128 Ibs ANCOOK, v ; t Splay wire anchor loading: V —F r 7.1 P =F x Tan 45 ° =F 9025 SW Center Street - PO Box 23784 Tigard, Oregon 97281 • Phone: (503) 620 -2088 Fax: (503) 684 -3636 . • NNicolin Project: TV 4R COMMAND AND BUSINESS OPERATIONS CENTER Page: I ` Cli ent: ANNINCs JOHNSON By: SET ENGINEERING, INC. Job No.: I00505 Date: LATERAL FORCE: AT 3RD FLOOR CEILINGS REF: ASCE 7 -05, SECTION 13.3 Using ASD load combination including 0.7E, where E = Q = F Ref: a = 100 [T13.5 -1] S OS = 0730 From project specifications or calculated using USGS Seismic Ground Motion Calculator with assumed Site Class = D W p =: 400.psf [13.5.6.1] Ip 1 [13.1.3] Rp = 2=50 For bracing components except anchors in concrete. [T13.5 -1] R =` 100 For anchors in concrete not governed by the strength [13.4.2] of a ductile steel element or not complying w/ ACI 355.2. z = 3600ft h 36:OOft For all bracing components except anchors in concrete: F = ( 0. 7)( O .4)a /(R /I +2(z/h)) = 1.47 psf [13.3 -1] For anchors in concrete not governed by the strength of a ductile steel element or not complying w/ ACI 355.2: F 0. 7)( 1. 3)( 0 .4)a /(R /I +2(z/h)) = 4.78 psf [13.3- 1],[13.4.2] F PMAx = (0 = 4.91 psf [13.3 -2] F PMIN = (0.7)0.3S = 0.92 psf [13.3 -3] USE F = 1.47 psf USE F = 4.78 psf Spacing of struts and splays, x -dir = 10 'ft ` Spacing of struts and splays, y -dir = '12ft Tributary area = (x- dir)(y -dir) = 120 sq. ft. Lateral force at each seismic brace location: FPBRACE = F x Tributary area = 177 Ibs V i r C ea. (, 1 we 9164 Lateral force for concrete anchor design (when applicable): Fpz BRACE = F x Tributary area = 5) . 4, , shear and tension in anchor N. A, T o 2 ! eL.vr,Kr Compression force in struts with splays at 45 degrees: PPOST = FPBRACE x Tan 45° = 177 Ibs k GA.o FDIC Ce?I 6>� Splay wire anchor loading: V=F P 45° P =F x Tan 45 ° =F 9025 SW Center Street - PO Box 23784 Tigard, Oregon 97281 • Phone:. (503) 820 -2088 Fax: (503) 884 -3638 �2 2001 NASPEC w/2004 Supplement Project: TVF &R COMMAND AND BUSINESS OPERATIONS CENTER Date: 6/1/2010 Model: COMPRESSION POSTS 1111 till R1 R2 8.00 ft Section : 162S125 -30 Single C Stud (X -X Axis) Fy = 33.0 ksi Maxo = 99.2 Ft -Lb Moment of Inertia, I = 0.060 in^4 Va = 543.0 Ib Loads have not been modified for strength checks Loads have not been modified for deflection calculations Flexural and Deflection Check Mmax Mmax/ Mpos Bracing Ma(Brc) Mpos/ Deflection Span Ft -Lb Maxo Ft -Lb (in) Ft -Lb Ma(Brc) (in) Ratio Center Span 0.0 0.000 0.0 None 41.7 0.000 0.000 L/0 Combined Bending and Web Crippling Reaction or Load Brng Pa Pn Mmax Intr. Stiffen Pt Load P(Ib) (in) (Ib) (Ib) (Ft -Lb) Value Req'd 1 R1 0.0 1.00 147.5 258.2 0.0 0.00 No R2 0.0 1.00 147.5 258.2 0.0 0.00 No Combined Bending and Shear Reaction or Vmax Mmax Va Intr. Intr. Pt Load (Ib) (Ft -Lb) Factor VNa M/Ma Unstiffen Stiffen R1 0.0 0.0 1.00 0.00 0.00 0.00 NA R2 0.0 0.0 1.00 0.00 0.00 0.00 NA Combined Bending and Axial Load Axial Ld Bracing (in) Max Allow Ld Intr. Span (Ib) KyLy KtLt KUr (Ib) P /Pa Value Center Span 177.0 (c) None None 218 178.3 (c) 0.99 0.99 I'/ ® Project: TVF4R COMMAND AND BUSINESS OPERATIONS CENTER Page: Is Client: ANNING JOI -INSON By: SET ENGINEERING, INC. Job No.: 100505 Date: h -1 -10 IS CHECK DIAG. WIRE SPLAYS : 12 GA CAPACITY OF WIRE = 0.60 Fy A = ( 0.60 )( 55,000 )( 0.0088 ) = 290# TENSION IN WIRE = 177 = 250# < 290# OK Cos 45° M CHECK FASTENERS : 3/8" HILT! KWIK BOLT TZ W/ 2" EMBEDMENT IN 4000 psi CRACKED CONCRETE OVER METAL DECK (REF: ICC ESR -1917) ALL VALUES MULTIPLIED BY 0.75 PER ACI 318 D.3.3.3 Pa = 0.75 Np,aeck,cr (fc / 2500) (1 /a) Pa = (0 .65)(0.75)(1460)(4000 /2500) 4 0.5 (1/1.4) = 643# P = 415 Va = CD 0.75 Vs,deck (1 /a) Va = (0.65)(0.75)(2130)(1 /1.4) = 742# V = 415 COMBINED LOADING: 643 / + ( 742 > 1.20 < 1.20 OK CHECK FASTENERS : WIRES TIED TO OPEN WEB JOISTS . °. ASSUME FULL STRENGTH OF WIRE M CHECK GRID : MAIN RUNNERS : ARMSTRONG 7501 CROSS TEES : ARMSTRONG XL 7590 CAPACITY OF CONNECTIONS (POUNDS): MAIN RUNNER IN TENSION 335 MAIN RUNNER IN COMPRESSION 335 CROSS TEE IN TENSION 352 CROSS TEE IN COMPRESSION 352 * CONTROLLING VALUE = 335 SAFETY FACTOR = 2 SAFE CAPACITY = 33 = 167.5 ASSUME \ OF GRID IS IN TENSION WHILE 1 IS IN COMPRESSION .•. CAPACITY = ( 167.5 )( 2 ) = 335 335# > 177# OK 9025 SW Center Street - PO Box 23784 Tigard, Oregon 97281 • Phone: (503) 820 -2088 Fax: (503) 884 -3838