Loading...
Correspondence / ( t �C 9 4 v lad/ DESIGNER ly 26,, 0 Mr. Dan Nelson — Senior Plans Examiner City if Tigard- Building Codes Division Re: Subject: Plans Examination Process Permit No.: MST2010 -00105 (Vasquez Residence Addition) Owner of Property: Miguel & Melissa Vasquez Site Address: 10475 SW Clydesdale Place, Tigard OR Site Legal: T2S R1W SO3AA Tax Lot 3100 WM Dear Dan Nelson: Please note that all items have indeed been addressed in our pervious correspondence. This letter will serve to offer compromise where compromise is possible, and to direct you to the sections of the code which allow design calculations where compliance with prescriptive methods is functionally impossible. 1.) Please see the applicant Melissa Vasquez and/or Nathan Fultz, representative for the general contractor, for copies of the truss calculations. 2.) The bearing wall which falls between the stairway and utility room simply transfers the loads from the second floor rim joist (B -9) to the first floor system. The existing 4X8 post and beam floor system (B -10) proves adequate to distribute those loads to terra-firma. In the event that you personally feel that this wall would be better served by additional in -line post and beam placed beneath the bearing portion of this wall, please feel free to add your notes on the approved set, with my blessings. 3.) A "TYPICAL PERIMETER FOOTING CHECK" calculation has been provided, again. This calculation verifies that even a 12" footing is adequate for the proposed loads. Please review section R301.1.3 Engineered Design. The enclosed calculations demonstrate that the existing 14" wide footing is adequate. In the event that you feel that your calculations indicate otherwise, please facilitate our discussion by submitting a copy of your calculations for our review. Thank you. Please find copies of calculations and proofs included. Thank you, Dan. Sin e - ly: 1,d /J/% /l/ kS'•t,Designe P.O. Box 710 • AURORA, OREGON 97002 • (503) 759 -3374 June 29, 2010 RE: ADDITION OF SECOND STORY P roject Information Building Permit: MST2010 -00105 Class of Work: NSFD Address: 10475 SW Clydesdale PI. Lot Number: NA Area: 938 Sq. Ft. Stories: 2 Builders Name: Nathan Fultz Subdivision: NA The plan review was performed under the State of Oregon Residential Specialty Code (ORSC) 2008 edition. Please respond to conditions below. 1) Provide engineered truss details. 2) Bearing walls on either side of stairs need to be addressed on foundation plan. 3) Existing exterior footing and foundation wall and existing header size needs to be verified as adequate for two story structure. Please verify with inspector prior to first inspection. 4) Calculation for eight foot header in master bedroom does not indicate all roof and floor loads. When responding, provide an itemized letter stating in what way each numbered issue has been addressed in the revision. When submitting revised drawings or additional information, please attach a copy of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. Respectfully, Dan Nelson Senior Plans Examiner (503) 718 -2436 dann @tigard - or.gov r/s a2 ono CleanWater Services vE Our commitment is clear. EC EI JUL 2 2 2010 i'.. :a CITY OF TIGARD July 20, 2010 VAZQUEZ, MIGUEL A & GUEST, MELISSA 10475 SW CLYDESDALE PL TIGARD OR 97223 RE: CWS file 10- 001583 (Tax map 2S103AA Tax lot 03100); Single Family Residence Addition Clean Water Services has received your Sensitive Area Certification for the above referenced site. District staff has reviewed the submitted materials including site conditions and the description of your project. Staff concurs that the above referenced project will not significantly impact the existing Sensitive Areas found near the site. In Tight of this result, this document will serve as your Service Provider letter as required by Resolution and Order 07 -20, Section 3.02.1. All required permits and approvals must be obtained and completed under applicable local, state, and federal law. This letter does NOT eliminate the need to protect Sensitive Areas if they are subsequently identified on your site. If you have any questions, please feel free to call me at (503) 681 -3653. Sincerely, Amber Wierck Environmental Plan Review 2550 SW Hillsboro Highway • Hillsboro, Oregon 97123 _ ___ _ �. ten, Dann _ r'Ie�n \AlefcrfcrvirPC nrn